2024

Benchmarking the Suitability of Novec $^{\mathrm{TM}}$ 4710 for Application in Flux Compression Generators

Authors: Nathan Fryar; Kirk Schriner; Jacob Stephens; James Dickens; Andrew Young; Andreas A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10494597

Abstract: An experimental study evaluated the feasibility of replacing traditional insulating gases such as SF $_{{6}}$ with C $_{{4}}$ F $_{{7}}$ N (3M, Novec 4710) in flux compression generator (FCG) applications. Currently available data indicate that Novec 4710 could offer certain performance benefits over SF $_{{6}}$ . However, the available literature is focused on low frequency (50–60 Hz) and dc at static pressures. To evaluate the performance of Novec 4710 under the pulsed dynamic pressure and temperature conditions found in an FCG, we report a performance comparison between three sets of identical FCGs using air, SF $_{{6}}$ , and Novec 4710 as the insulating gas. The generators used in this study had a single stage, directly seeded design with an armature diameter of 25 mm and a stator diameter of 46 mm. To highlight the performance of the different gases rather than any wire insulation, the stator was constructed with uninsulated wire. Furthermore, the generators were seeded aggressively, making the performance difference between the different gases more apparent. The performance was monitored with a pair of differential Rogowski coils that captured the generators’ di/dt while also using high-speed videography to capture possible gaseous breakdown signatures. The data gathered during this study indicate that Novec 4710 performs at least as well as SF $_{{6}}$ in FCG applications, if not significantly better.

Early Access Articles

Effect of Approach Speed and Electrode Geometry on Electrostatic Discharges Off Floating Dielectrics

Authors: B. Esser; Z. Cardenas; J. T. Mockert; J. C. Stephens; J. C. Dickens; J. J. Mankowski; A. A. Neuber; D. Friesen; D. Hattz; C. Nelson

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10485615

Abstract: With the damaging effects of electrostatic discharges (ESDs), it is important to study them within various parameter regimes relevant to real-world scenarios. One such scenario studied here is a floating dielectric with no nearby ground plane with a grounded object approaching at a high rate of speed. One may encounter this scenario when moving objects by hand. Discharge current and radiated fields are captured for discharges drawn from polytetrafluoroethylene (PTFE) and poly methyl methacrylate (PMMA) with approach speeds ranging from 20 to 100 mm/s. Previous studies have shown that at lower speeds in metal-to-metal or metal-to-ground backed dielectric geometries, the peak current and discharge distance decrease with increasing speed. However, in the speed range studied here, an increase in distance and current are observed for increasing speed. Namely, the highest speeds coincide with the highest peak currents and discharge distances of approximately 800 mA and up to 24 mm. With no grounded backing, as opposed to setups in other ESD studies, the electric field between the dielectric and an approaching electrode has a more uniform distribution with highest fields at the electrode, which is elucidated to be the driving factor in the differences revealed in this study. Two spheres of differing diameters and a conical electrode are used to draw discharges off the dielectric surfaces. Captured radiated fields via B-dot sensor, plasma imagery via intesified charge-coupled device (ICCD), and mapping of surface potential reveal that a majority of the energy lost during a discharge goes to gas losses and radiated fields.

Early Access Articles

2023

A 1D1V Continuum Vlasov–Poisson Multipactor Analysis From Onset to Saturation Across the Entire First-Order Multipactor Regime

Authors: Luke Silvestre; Jacob Stephens; James Dickens; John Mankowski; Andreas Neuber; Ravindra P. Joshi

PDF: https://ieeexplore.ieee.org/abstract/document/10033097

Abstract: This report employs a Vlasov–Poisson model to elucidate fundamental electron phase–space mechanics of a multipactor discharge from onset to saturation. At the onset of multipactor, the electron phase–space is primarily defined by sharp features in both the physical space and energy space. With increasing electron density, space-charge effects lead to debunching of the swarm in phase–space. The temporal evolution of the electron energy distribution is studied across a single impact cycle. The average and peak-to-peak saturation values for the entire first-order multipactor regime are presented. Comparisons between the third- and fifth-order multipactors highlight the nuanced similarities and differences in the energy distribution of the multipacting system. The Vlasov–Poisson approach, which neglects collisions, is well suited for such analysis since the multipactor phenomenon occurs under near-vacuum collisionless conditions. It also overcomes difficulties associated with kinetic schemes that require adequately sampling all of the electron phase–space, including sparely populated regions, or special treatments to model strong growths in carrier densities.

Journal

Air Core Transformers for Use in Flux Compression Generator Power Conditioning

Authors: Tyler Watson; James Dickens; Andreas Neuber; John Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10310794

Abstract: Flux compression generators (FCGs), are unable to drive high impedance loads efficiently. To ensure that the output from an FCG can drive a high impedance load, an impedance transformation is necessary. This impedance transformation is known as the power conditioning stage of the FCG. Air core transformers were developed to eventually be used as a power conditioning stage for an FCG. Two types of air core transformers were developed, known as the C-TACT and COAX-ACT. The design and fabrication of these types of ACTs are discussed, along with experimental results and simulation. Finally, a comparison is made between the developed ACTs.

Conferences

An apparatus for probing multipactor in X-band waveguide components

Authors: A. Gregory; D. Wright ; H. Spencer ; J. J. Mankowski ; J. C. Dickens ; J. Stephens; A. A. Neuber

PDF: https://pubs.aip.org/aip/rsi/article/94/5/054705/2888169/An-apparatus-for-probing-multipactor-in-X-band

Abstract: Rectangular waveguides are susceptible to avalanche-style breakdown via the multipactor phenomenon. The growth in secondary electron density produced via multipactor can damage and destroy RF components. A pulse-adjustable, hard-switched modulator powering an X-band magnetron was utilized to drive a modular experimental setup that enables testing different surface geometries and coatings. Power measurements, taken via diodes, and phase measurements, facilitated via a double-balanced mixer, were integrated into the overall apparatus enabling multipactor detection with high sensitivity and nanosecond temporal resolution. The utilized 150 kW peak microwave source with 2.5 μs pulse width and 100 Hz repetition frequency allows for threshold testing without the need for initial electron seeding. This paper includes the initial results of surface conditioning of the test multipactor gap via electron bombardment.

Journal

Experimental Demonstration of a Compact, High Average Power, Pulsed Power Driver for Printed-Circuit Board Nonlinear Transmission Lines

Authors: David Saheb; Travis Wright; John Mankowski; James Dickens; Andreas Neuber; Emily Schrock; James Schrock; Jacob Stephens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10310677

Abstract: Nonlinear transmission lines (NLTLs) are a promising technology for high power microwave (HPM) generation. However, NLTLs are also typically characterized by relatively short RF pulse widths, on the order of tens to hundreds of nanoseconds. One approach to increasing the overall average microwave power is the application of short excitations in very high pulse repetition frequency, thus yielding a high effective RF duty cycle. This research details the development of a compact pulsed power driver capable of delivering up to 3 kV high voltage excitation, with pulsed widths between 100 – 500 ns, and multi-MHz pulse repetition frequency to a PCB-based NLTL HPM source.

Conferences

Experiments to Quantify the Shielding Efficacy of Materials to be Implemented for Portable Shielding Enclosures that Adequately Mitigate EMI from Lighting Attachment Events

Authors: Jake Slattery; Austin T. Hewitt; Brandon Bywater; John Mankowski; James Dickens; Andreas Neuber; Donald Friesen; David Hattz; Craig Noltensmeyer; Neil Koone; Crystal Nelson; Jacob Stephens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10376245

Abstract: Mitigating electric and magnetic fields induced by lightning strike events is critical for the security and longevity of electrical components. Electromagnetic interference originating from a lightning strike is categorized into the low to medium frequency ranges, commonly referred to as the “magnetic coupling’’ regime. This low-frequency characteristic brings about the problem of shielding magnetic flux lines. Such shielding can be accomplished with highly conductive materials via the generation of eddy currents or by diverting the flux lines using materials with a large relative permeability. The shielding effectiveness of materials with varying thicknesses and geometry are tested using a pulse forming network having comparable characteristics to a scaled lighting strike. A four-stage Marx generator with a peak current of $\sim$33kA and a risetime of 1.4 $\mu$s is used as the pulse forming network to emulate the scaled electric and magnetic fields. The data collected from these experiments provide information and techniques that can be implemented into the design of a portable, deployable shielding enclosure.

Conferences

High Power Microwave Breakdown of C4F7N (Novec 4710) Gas Mixtures

Authors: Brandon Bywater; John Mankowski; James Dickens; Andreas Neuber; Matthew Capps; Jacob Stephens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10310949

Abstract: Sulfur Hexafluoride’s (SF6) high dielectric strength makes it heavily relied upon as a high voltage insulating medium. However, its atmospheric lifetime of 3,200 years and overall high global warming potential has motivated a search for alternatives. One possible alternative, C4F7N (NOVEC 4710) features a dielectric strength more than twice that of SF6 yet features an atmospheric lifetime one-hundredth that of SF6. Previous research concerning breakdown characteristics of C4F7N has been primarily limited to long-timescale DC and 60 Hz AC conditions. In this study, the breakdown strength of gas mixtures comprised of 5%, 10%, and 20% C4F7N in a N2 or CO2 background were tested under pulsed, microsecond high power microwave (HPM) conditions over a range of 16 psia to 32 psia at room temperature. To achieve this, a 3 MW S-band (2.85 GHz) high-power magnetron is used to excite a traveling-wave ring resonator, which provides a nominal effective HPM power level of ~20 MW. A stepped impedance transformer is used to further increase the electric field to approximately 160 kV/cm RMS. For comparison, the reported dielectric strength of C4F7N is compared against the dielectric strength of pure SF6.

Conferences

Investigation of Multipactor in X-Band Waveguide Filters

Authors: D. Wright; A. Gregory; H. Spencer; J. Mankowski; J. Stephens; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10481093

Abstract: The increased need for multi-carrier signals and higher power requirements has made it essential to study the multipactor (MP) phenomenon in practical structures. A 3-stage rectangular waveguide filter has been designed and implemented in a plug-and-play test fixture for X-band frequencies. The test source for this system is a coaxial magnetron, which yields a peak power output of 150 kW at a frequency of 9.4 GHz and a pulse width ranging from 0.25 to 2.5 μs. Global power diagnostics and phase detection methods were employed to detect MP in the system.

Conferences

Methods for Mapping of Surface Charge Density on Arbitrary Dielectric Objects

Authors: John Mockert; John Mankowski; Benedikt Esser; Donald Friesen; Blake Havens; David Hattz; James Dickens; Crystal Nelson; Jacob Stephens; Andreas Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10310963

Abstract: A system to map surface charge densities on dielectric objects – e.g. PTFE, PMMA, and PA6 – is described to study maximum surface charge limits discharge and decay characteristics. Two electromechanical movements are used to achieve these goals: a three-axis robotic arm with an electrostatic probe and a three-axis auxiliary movement fitted with a current viewing resistor and laser displacement sensor. Dielectric objects no larger than a cylinder of eight-inch diameter and twelve inches in height are analyzed to create surface point clouds and generate a set of scan points. The arbitrary object is positioned upon a rotational axis with a laser displacement sensor oriented radially towards the rotational axis of the platform to determine the object’s physical limits.

Conferences

2022

A Continuum Approach For Multipactor Using Vlasov-Poisson Analysis

Authors: Silvestre, L; Shaw, ZC; Sugai, T; Stephens, J; Mankowski, JJ; Dickens, J; Neuber, AA; Joshi, RP

PDF: https://iopscience.iop.org/article/10.1088/1361-6463/ac2c38/pdf

Abstract: Multipactor is studied based on the coupled Vlasov-Poisson equation set and applied to a parallel plate geometry. This approach can be considered complementary to the particle-in-cell (PIC) methods that have provided excellent insight into multipactor behavior. However, PIC methods have limitations in terms of 'particle noise,' which can affect electron energy distribution functions and create re-scaling issues under conditions of charge growth. Utilizing our continuum Vlasov-Poisson approach yields susceptibility curves that are in line with reports in the literature, Spark3D PIC simulations, and experimental data. Playing to the strength of the Vlasov-Poisson approach, the differences between various multipactor orders are elucidated as they are observed in phase-space, revealing electron density dynamics without requiring increased computational resources due to electron growth. The method presented is general and can be extended to multi-input excitations and higher-dimensional phase-space.

Journal

An Investigation Into The Surface Skidding Response Of Pbx 9501 And Pbx 9502

Authors: S. A. Watkins, R. J. Lee, T. H. Austin, J. Mankowski, J. Brinkman, J. Dickens, A. A. Neuber

PDF: https://onlinelibrary.wiley.com/doi/full/10.1002/prep.202200010

Abstract: While polymer-bonded explosives, PBX, have reduced sensitivity to ignition from mechanical shock or heating compared to conventional explosives, the investigation of the mechanical ignition mechanisms for PBX remains vital to assessing the safety during machining and general handling. Under frictional heating, hot spot generation due to high melting point contaminants in the interface is a suspected source for increased probability of ignition. To investigate such frictional heating, samples of PBX 9501 and PBX 9502 were impacted and skidded against a tangentially moving target and thermally imaged. Temporally resolved temperature and forces were simultaneously measured with and without 300 μm silica grit at the frictional interface. A trend of increasing temperature was observed as the speed and tangential force on the sample increased. Grit particles in the frictional interface were found to act as frictional heat concentration spots owing to the grit‘s protrusion from the surface and lesser susceptibility to melting compared to the PBX. The coefficient of friction between PBX 9501 and the skidding surface was observed to be largely constant for forces and speeds at the lower end of the test range. In contrast, at high tangential speeds, the coefficient was found to be significantly lower.

Journal

Assessing the Role of Photon Processes in Facilitating Radio Frequency Breakdown of Air at Atmospheric Pressure in Millimeter Gaps

Authors: Xiaoli Qiu; Benedikt Esser; Ivan Aponte; John Mankowski; James C. Dickens; Andreas A. Neuber; Ravi P. Joshi

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9925595

Abstract: The behavior of the breakdown electric field versus gap lengths (in the 1–5-mm range) and at different frequencies in the 1–80-MHz span, has been studied numerically at atmospheric pressure. Unlike previous studies of radio frequency (RF) breakdown, the role of photon-emission processes is explicitly included and shown to be important for large-area electrode configurations. Numerical analysis based on Monte Carlo calculations is used to predict the breakdown thresholds. The simulations embed a statistical photon transport model, based on random selections of emission angles and times from excited atoms, as well as photoemission from the electrodes. Simulation results compare well with experimental data from our group, but only with the inclusion of photon processes. Though both photoemission and photoionization are included in the breakdown physics, the former is identified as the dominant process. The frequency behavior of breakdown fields is also assessed with the inclusion of photons, and the results reveal a U-shaped trend with increasing values for smaller gaps.

Early Access Articles

Evaluation of Explosive Emission Carbon Fiber Cathodes for High-Power Microwave Devices

Authors: Tyler Buntin; Matthew Abide; Andreas Neuber; James Dickens; Ravindra Joshi; John Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9893540

Abstract: Most high-power microwave (HPM) sources, such as the magnetically insulated transmission line oscillator (MILO) being developed at Texas Tech, utilize cold cathodes that generate electrons via explosive emission. Highly emissive cathodes such as the presented can generate current densities and currents greater than 1 kA/cm 2 and 10 kA, respectively, which are required for devices that can output radio frequency (RF) power greater than 100 MW. Typically, these cathodes are made of materials such as metal, silk or synthetic velvet, carbon fiber, and cesium iodine (CsI)-coated carbon fiber. In order to optimize the MILO performance, we fabricated carbon fiber velvet cathodes and compare their performance with other commercially available carbon fiber cathodes. Fabrication was done on a manual, mechanical loom using commercially available carbon fiber thread. Four carbon fiber cathodes were tested: in-house fabricated monomodal carbon fiber velvet, in-house fabricated bimodal carbon fiber velvet, in-house fabricated carbon fiber plain weave cloth, and bimodal carbon fiber velvet manufactured by ESLI Inc. Testing was performed in a vacuum chamber with variable AK gap in the high vacuum range (10−7 torr). High-speed optical imaging was performed in order to determine the uniformity of the generated plasma as well as the e-beam. Voltage and current measurements were performed to determine diode impedance and perveance.

Journals

Exploring the Basic Physical Mechanisms of Cathode- and Anode-Initiated High-Voltage Surface Flashover

Authors: W. Brooks; R. Clark; J. Young; M. Hopkins; J. Dickens; J. Stephens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9779121

Abstract: Surface flashover in vacuum imposes a substantial physical limit on modern, large-scale pulsed power. One of the ramifications is a minimum size requirement for new machines, which in itself becomes a hard barrier to the modernization and improvement of existing infrastructure. Pulsed power topologies require the physical mechanisms of both anode- and cathode-initiated flashover to be considered. Originally, the geometrical implications of field emission at the cathode triple junction (CTJ) motivated the usage of configurations that avoid electrons impinging on the insulating material. This will largely suppress the cathode-initiated flashover, which is best described by the secondary electron avalanche mechanism, gas desorption, and final breakdown in the desorbed gas. It depends on the cascade growth of a conducting plasma along the length of the insulator from the cathode. Mitigating the cathode-initiated flashover typically comes at the cost of a significant field enhancement at the anode triple junction (ATJ). In a typical implementation, the anode field may be three times higher than the cathode field for a given voltage, making the corresponding anode-initiated flashover much more common than otherwise. In the case of pulsed, anode-initiated flashover, experimental evidence suggests that charge is directly extracted from the insulator resulting in the insulator taking on a net positive charge advancing the anode potential. Along with accompanying gas desorption from the surface, the potential will then propagate from the anode toward the cathode until the effective length of the gap is sufficiently reduced to support flashover. The underlying physical mechanisms of cathode- and anode-directed flashover are discussed in light of previously gathered experimental data and recent experiments with pulsed, high-gradient, anode-initiated flashover.

IEEE Early Access Articles

Lightning Current Propagation in Electrical Conduit

Authors: William Brooks; Micah Lapointe; Landon Collier; John Mankowski; James Dickens; David Hattz; Neil Koone; Andreas Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9664800

Abstract: Investigation of lightning strikes to conductors ran through long spans of rigid steel conduit was performed. An overdamped-exponential current waveform with controlled peaks and rise rates was used to inject simulated lightning strikes. The impact of the length of wire, length of conduit, grounding location/s, and load type was investigated. Breakdown of 600 V, 12 AWG, THHN insulated wire (3.23 mm OD, 2 mm conductor diameter) was observed for voltages above 45 kV. The presence of resistive loads (between wire and ground) in excess of 20 $\Omega $ or current rise times in excess of 5 kA/ $\mu \text{s}$ were found to consistently produce breakdown between wire and conduit. Practical power circuit elements such as outlets and splices were found to breakdown at voltage levels much below the wire insulation failure threshold.

Journals

Optically Activated In-Waveguide Semiconductor Attenuators for the Controllable Isolation of Ka-Band Microwaves

Authors: A. T. Hewitt; B. Esser; R. P. Joshi; J. Mankowski; J. Dickens; A. Neuber; R. Lee; J. Stephens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9700732

Abstract: Three different isolator topologies utilizing photoconductive (PC) elements are explored for their application as a controllable attenuator for a Ka-band radar system. Network analyzer measurements are reported for each geometry in the unilluminated case, while a high-speed, high dynamic range heterodyne detection apparatus is used to measure the transient attenuation behavior of the isolators when illuminated. The electromagnetic characteristics of the illuminated isolators are demonstrated to be in good agreement with COMSOL Multiphysics simulations. Two of the isolator topologies rely on the PC element becoming highly reflective to achieve high isolation, which in turn requires high optical power and charge carrier density (~1017 cm $^{-3}$ ). For the optical power available here (100 W), the first device demonstrated a peak attenuation of 53 dB, while the second device achieved only 33 dB. In the third topology, RF propagation is parallel to the major dimensions of the PC element. As a result, superior isolation is achieved with the PC element in the primarily absorbing state, associated with significantly lower carrier concentration (~1015 cm $^{-3}$ ). This device achieved 63 dB of attenuation for only 3 W of optical power, demonstrating that PC technologies may be competitive with other isolator technologies with some notable advantages.

Journals

RF Output Power Detection of the RADAN MG-4 Microwave Generator

Authors: Nicholas Harrison; Kaylee Allen; James C. Dickens; Andreas A. Neuber; John Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10099412

Abstract: The RADAN series-based MG-4 Microwave Generator is a compact, high power microwave system developed by the Institute of Electrophysics in Ekaterinburg. The system features the RADAN high voltage generator which is a SINUS-series device featuring a Tesla transformer charger and a Blumlein pulse forming line. The MG-4 microwave head is a mm-band relativistic backward wave oscillator (BWO) that operates at 35 GHz with a 5 to 10 MW peak output power and a pulse width of 3 ns. To confirm the RF output power level of the MG-4, a commercially available RF envelope detector was employed. Analog Devices ADL6012 is a broadband envelope detector that operates from 2 GHz to 67 GHz at input powers up to $+15 \ \text{dBm}$, It also features a 500 MHz envelope bandwidth and 0.6 ns output risetime capability. The diagnostic setup features the ADL6012-EV ALZ, an evaluation board with the ADL6012 offered by Analog Devices, shielded in a fitted brass box located in the far field $(\sim 60$ cm) from the microwave output horn. The output mode of the MG-4 is nominally TM0l, but a mode convertor allows for a TE11 output mode as well. The positive and negative envelopes of the pulse are captured separately. Based on the peak differential output voltage of the positive and negative signal, the input power of the detector can be determined by the typical performance characteristics curves in the ADL6012 data sheet. Lastly, accounting for the attenuators, antennas, and free space path loss, the peak output power of the MG-4 can be accurately determined.

Conferences

Sensitivity of Multipactor on Variations in SEY using a Continuum Vlasov-Poisson Model*

Authors: L. Silvestre; R. Joshi; J. Stephens; J. Dickens; J. Mankowksi; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9813001

Abstract: The impact of secondary electron yield (SEY) variations on multipactor in a parallel plate geometry is probed. In this contribution, electron swarm dynamics are simulated via the continuum approach across a variety of SEY curves. The objective is to determine which changes and shifts in the SEY curve are most sensitive to the final multipactor outcome. For instance, will a variation in the maximum SEY yield while retaining the first crossover energy produce significant changes in the MP susceptibility? To parameterize, the probed SEY curves are approximated by suitable square, triangular, or trapezoidal shapes and fed into the Vlasov-Poisson-based MP model to evaluate the impact of chosen energy-dependent deviations on multipactor. A shaped approximation of the SEY curve has already shown to produce signifigant changes in multipacotr susceptibility especially in the 1 st order regime. Variations in the 1 st and 2 nd crossover points of the SEY curve are also compared within the same susceptibility graphs. The results of this Vlasov-Poisson method are benchmarked against commercial software, particularly Spark3D. The results obtained and implications of SEY deviations on multipactor will be presented and discussed.

IEEE Conferences

2021

Apparatus For Skidding Sensitivity Testing Of Energetic Materials

Authors: Hewitt, AT; Lee, RJ; Watkins, S; Brinkman, J; Stephens, JC; Dickens, JC; Neuber, AA

PDF: https://aip.scitation.org/doi/10.1063/5.0043825

Abstract: A remote-operated apparatus for testing the detonation sensitivity of energetic materials is detailed. Using an air ram and rotating disk, the normal force and transverse velocity of the impact plane are controlled independently, enabling the exploration of varying impact conditions over a wide parameter space. A microcontroller local to the apparatus is used to automate apparatus operation and ensure temporal alignment of the impacting ram head with the rotating disk. Calculation of the firing parameters and issuing of operational commands are handled by a remote computer and relayed to the local microcontroller for execution at the hardware level. Impact forces are taken from fast strain measurements obtained from gauges incorporated into the ram head. Infrared imaging of explosive samples provides insight into the peak thermal temperatures experienced at the sample surface during the impact event.

Journal

Effect of Humidity on Charge Decay in Varying Atmospheric Gases

Authors: Zachary Cardenas; Ben Esser; Ivan Aponte; James Dickens; John Mankowski; Jacob Stephens; Donald Friesen; Crystal Nelson; Neil Koone; David Hattz; Andreas Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9733134

Abstract: Characterization of surface charge decay for varying materials – PTFE, Acrylic, and metals – of 100 mm diameter, radially symmetric bodies was performed. In a gaseous environment, charged materials will lose their charge depending on gas type, humidity, and other environmental factors. Eventually, the charge will be (1) neutralized by ions or electrons in the surrounding gas (2) distributed by conduction on the material surface or in its volume (3) or neutralized by ions or electrons in the material surface and volume. Metal and polymer samples are charged to a known potential in the tens of kilovolts range, and the decaying voltage is monitored with a non-contact probe until the potential reaches near zero. Humidity has an impact on both groups of materials. As a baseline, in air at 42% relative humidity in an enclosed chamber, a positive charge equivalent to 20 kV potential on a metal sphere of 50 mm radius decays to near zero within 25 minutes. In contrast, the same sphere negatively charged decays slightly faster within 20 minutes. Overall, the humidity has a significant effect on the charge decay time, such that an order of magnitude longer times (hours) are observed at low humidity. Effects of chamber size were also studied, drawing a connection to charge carriers in the air available for decay, with chambers of volume(s): 3.3 105 cm3 and 1.4 106 cm3, respectively.

Conferences

Fundamental Investigation Of Unipolar And Rf Corona In Atmospheric Air

Authors: Aponte, IA; Esser, B; Dickens, JC; Mankowski, JJ; Neuber, AA

PDF: https://aip.scitation.org/doi/10.1063/5.0061663

Abstract: Unipolar (DC) and radio frequency (RF) corona at 3.3 MHz is studied at centimeter-sized gaps in a needle-plane geometry in atmospheric air at room temperature. Positive and negative corona using pure tungsten electrodes with varying tip angles revealed a lower onset voltage for the needle with the smaller included angle. The RF corona onset voltage and corresponding time delay were measured for a series of needles composed of pure tungsten or 2% lanthanated tungsten. The corona onset, established when the first instance of UV photon emission is detected via photomultiplier tube, occurred primarily during the negative half cycle of the applied RF voltage for pure tungsten needles. In contrast, with lanthanated tungsten needles, such preference was not observed. No distinguishable difference in onset voltage between pure tungsten and lanthanated tungsten was found, indicating that adding a small amount of lanthanum to tungsten has a negligible impact on the onset voltage at 3.3 MHz frequencies for electrodes at room temperature.

Journal

High Power Multipactor Suppression in X-Band Waveguide

Authors: A. Gregory; Z. C. Shaw; D. Wright; J. Mankowski; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9733122

Abstract: The multipactor effect is detrimental in space-based RF systems through detuning, heating, and causing permanent component damage. Studying thresholds and suppression of multipactor utilizing surface geometries in structures akin to WR-90 waveguide are of specific interest in the presented work. Operating in the dominant TE10 mode, a copper stepped impedance transformer transitions the waveguide to a 1.5 mm height, providing a frequency-gap product conducive for multipactor ignition. The stepped impedance transformer housing is designed as a plug-and-play system, allowing for quick swapping different stepped impedance transformer heights or materials. Input power is injected into the test gap from a coaxial magnetron, operating at 9.4 GHz with a peak power of 250 kW and 2.5 µs pulse width.The setup will enable the measurement of base thresholds for a machined and polished copper surface (material that has undergone a simple cleaning process only), as well as thresholds for multipactor suppression geometries. The testing apparatus details, including the phase-sensitive diagnostics, are presented

IEEE Conferences

Model Evaluations Of Multipactor Suppression In Rectangular Waveguides Through Grooved Surfaces And Static Magnetic Field

Authors: Qiu, X; Saed, MA; Mankowski, JJ; Dickens, J; Neuber, A; Joshi, RP

PDF: https://aip.scitation.org/doi/10.1063/5.0029859

Abstract: Mitigation of multipactor in waveguides is of importance, and strategies have included the addition of external fields, materials engineering, or surface modifications. Here, geometry modifications of rectangular waveguide surfaces and the application of an axial magnetic field are investigated for suppressing multipactor growth. A Monte Carlo approach has been used to simulate electron dynamics. The empirical secondary electrons yield is modeled based on a modified Vaughan approach. The electric fields driving electron transport were derived from separate electromagnetic calculations to adequately include field perturbations due to the presence of surface patterns in the rectangular waveguide structure. Combinations of grooves and a DC magnetic field are shown to effectively mitigate multipactor growth at field strengths up to similar to 10(5) V/m. Finding optimal combinations for an arbitrary field and operating frequency requires further work.

Journal

Sensitivity of PBX 9501 and PBX 9502 to Milling Operations

Authors: J. Williams; E. Weeks; R. Clark; S. Watkins; J. Dickens; J. Mankowski; J. Brinkman; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9733143

Abstract: Explosive driven pulsed power performance benefits from modern polymer-bonded explosives. In practical application, high precision in the dimensional shape is required, and high machining speeds are desired. The limits of machining speed, driven mainly by the thermal response of the energetic material, are investigated. Specifically, the thermal response of PBX 9501 (95% HMX, 2.5% Estane, 2.5% BDNPA/BDNPF by weight) and PBX 9502 (95% TATB, 5% Kel F-800 by weight) under conventional milling methods is examined. The presented work focuses on face milling performed with dry machining on a CNC, remote-controlled milling machine. The primary parameters of interest are the spindle speed, feed rate, step size, and depth of cut, with additional consideration given to endmill diameter, milling technique, and the number of flutes. The temperature of the system is monitored via high-speed IR videography and near the cutting interface with a K-type thermocouple inserted into the endmill’s through-coolant hole. Operational forces and torques are recorded by a 6-axis force sensor mounted beneath the HE samples.An empirical relationship between temperature and the milling parameters is presented. Overall, milling regimes exist outside of DOE-STD-1212-2019 for which milling temperatures remain well below the HE critical temperatures.

IEEE Conferences

Surface Charge Distribution Mapping Using an Electrostatic Probe

Authors: M. LaPointe; B. Esser; I. Aponte; Z. Cardenas; J. Dickens; J. Mankowski; J. Stephens; D. Friesen; C. Nelson; N. Koone; D. Hattz; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9733129

Abstract: Undesired accumulation of charge on dielectric materials causing electrostatic discharges can be an issue in pulsed power systems and electrical systems in general. As such, an understanding of surface charge distribution, charge accumulation, and decay is required. An in-house no-contact electrostatic probe designed with a 2 mm resolution was fabricated to measure and map surface charge distribution. Designed as a contactless instrument, the probe consisting of a metal rod and low leakage amplifier circuit probes the electric potential near the surface. A scan of the surface then provides the raw data, a potential distribution. The actual probe response - i.e., the surface charge to voltage transfer function, is accounted for in post-processing. This is accomplished via an Inverse Wien Filter - a technique often applied in image processing - to deconvolve the probe response from the measured data. A commercially available electrostatic probe, the Trek 341B meter with a 3455ET probe, capable of measuring +/- 20 kV was compared to the in-house probe that is designed to cover a wider range from +/- 35 kV. A resolution better than the simple probe resolution is achieved through the distribution’s scanning voltage method and deconvolution. Applying repeated scans, surface charge decay was tracked on various polymer materials to determine the material and environment dependence; materials included were PA6, PTFE, and others. As an example of material dependence, samples charged to 20 kV at 65% humidity experience full charge decay in approximately 45 seconds for PA5 (152 mm dia.), while it took about 100 times longer for PTFE (51 mm dia.) to observe the same decay/redistribution of charge.

IEEE Conferences

2020

A 2 Kw S-Band Rf Source For Multipactor Research Utilizing Gan Hemts

Authors: Esser, B; Shaw, ZC; Dickens, JC; Neuber, AA

PDF: https://aip.scitation.org/doi/10.1063/5.0009836

Abstract: A high power, pulsed RF source designated for use in multipactor research is described. Four gallium nitride high electron mobility transistors from Cree/Wolfspeed, capable of 700 W in long pulse mode (500 W rated output), are combined to achieve a maximum rated output of 2.8 kW with a pulse length of similar to 100 mu s. Custom splitters/combiners are used due to the power levels considered in addition to a custom power and sequencing control system to ensure the proper biasing and sequencing of the relatively delicate depletion mode GaN devices. With high efficiency and small size, gallium nitride devices present a good solution for lab based sources, and this paper aims to provide information helpful in the construction of such a source. The multipactor phenomenon itself is studied within a high impedance waveguide section-achieved with a tapered impedance transformer-placed in a WR284 traveling wave ring resonator, which increases the effective power up to a factor of 20, or similar to 40 kW.

Journal

A Study on the Contributing Factors of RF Breakdown in Atmospheric Air

Authors: I. A. Aponte; B. Esser; J. C. Dickens; J. J. Mankowski; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9717642

Abstract: DC and RF breakdown at 3.3 MHz was studied in centimeter size gaps − 1 − 10 mm – with comparison to small gaps in literature and Monte Carlo simulations in atmospheric conditions. As a point of reference, DC breakdown using stainless-steel Bruce-profile electrodes were measured to compare with RF measurements. RF breakdown with a slow rising envelope ($\sim 5\ \text{mV}/\mu\mathrm{s}$) yielded approximately 80% of DC measurements (∼25 kV/cm in 5 mm gap), which agrees with Monte Carlo simulations and results found in literature. Increasing the envelope rise time to greater than $1000\ \mathrm{V}/\mu \mathrm{s}$ yielded ∼120% of DC measurements (∼37 kV/cm in 5 mm gap). Comparisons with Monte Carlo simulations which included photon processes – theorized to be critical to obtaining accurate results – furthered understanding of the processes involved in pre-ionization before breakdown occurs.

IEEE Conferences

Analysis Of Experimental Multipactor Observation Signals Using Spark3D Software

Authors: T. Sugai; Z. Shaw; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9717525

Abstract: Multipactor is a resonant nonlinear electron multiplication effect that may occur in high power microwave devices at very low pressures, such as those operating in particle accelerators and satellite subsystems. Its effects range from signal degradation to the damage and destruction of microwave components. Thus, multipactor physics has been studied through theoretical analysis, numerical simulation, and experiment. Previously, we developed a direct electron observation system using an Electron Multiplier Tube (EMT) and succeeded to directly detect multipactoring electrons in the center of the broadwall of rectangular waveguides 1, 2. Here, we provide a method for evaluating the electric charge density and secondary emission yield (SEY) in waveguides. The experimentally obtained EMT signal is analyzed with the extensive usage of the numerical simulation software Spark3D. The software was utilized to analyze multipactor onset in waveguide structures, where the electric field distribution without multipactor was carefully simulated, employing high-frequency solvers. The EMT signal and the charge density were simulated for the same conditions as the experiment. As a result, a calibration line indicating the proportional relation between the EMT voltage and the charge density, which is independent of some conditions, i.e., input power and gap size, was obtained. Further, after adjusting the SEY curve imported to Spark3D, the rising shape of the experimental EMT signal pulses fit with the simulated one, and the experimental threshold power for the EMT signal generation was consistent with the simulated multipactor threshold power. Since the simulation matches the experiment in threshold power and signal shape, one expects that the charge density and SEY curve deduced from the simulation are accurate.

IEEE Conferences

Analysis Of Multipactor In A Rectangular Waveguide Using Spark3D Software

Authors: Sugai, T; Shaw, Z; Dickens, J; Neuber, A

PDF: https://aip.scitation.org/doi/10.1063/5.0011641

Abstract: Multipactor is a resonant nonlinear electron multiplication effect that may occur in high power microwave devices at very low pressures, such as those operating in particle accelerators and satellite subsystems. In this research, multipactor of a rectangular waveguide was analyzed using the commercially available, numerical simulation software Spark3D. The electromagnetic wave in the simulation was a TE10 mode-2.85GHz wave of varying power, fed into the impedance transformer waveguide. At the lowest threshold, multipactor is generated in the minimum height region in the impedance transformer and nowhere else. More precisely, the multipacting electrons have a continuous energy distribution since the emitted secondary electrons carry a random initial velocity distribution. We observed that there are cases where the impact electron energy decreases despite an increase in power due to growing non-resonance of the microwave field and electron oscillations, resulting in not only two threshold points where secondary emission yield (SEY)=1 but several more. As a consequence, it was uncovered that when the average SEY in the highest field region is close to or less than one, multipactor may be caused in a lower field region where the SEY is effectively higher than one. The numerical results are compared with data from the experiment. While there is some deviation between the thresholds obtained from Spark3D and the experiment, the results at higher power levels are consistent with the experiment in the view of the SEY for each power level.

Journal

Coupled Analysis To Probe The Effect Of Angular Assignments On The Secondary Electron Yield (Sey) From Copper Electrodes

Authors: Qiu, X; Diaz, L; Sanati, M; Mankowski, J; Dickens, J; Neuber, A; Joshi, RP

PDF: https://aip.scitation.org/doi/10.1063/5.0010389

Abstract: Secondary electron emission from copper is probed utilizing Monte Carlo simulations that take account of elastic scattering based on the Mott theory and inelastic collisions based on energy-dependent energy loss functions. The loss function and stopping power were obtained through first-principles density functional theory. Angular assignment of electrons following elastic scattering or the creation of secondaries is shown to affect the energy-dependent secondary electron yield (SEY). A good match of the simulation results (with a peak SEY of similar to 180% at around 300eV and less than 10% deviation over the 0 to 1000eV energy range) to available experimental data is shown based on an energy and momentum conservation scheme. Also, the distribution of delay times for the generation of secondaries, the SEY behavior at different incident angles, the energy distribution of emergent secondaries, and their creation profiles as a function of depth are computed to provide a more complete picture of the governing mechanisms and predicted responses.

Journal

Development of a Vlasov Equation Based Numerical Model of Multipactor Discharge

Authors: L. Silvestre; R. Joshi; J. Stephens; J. Dickens; J. Mankowski; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9717616

Abstract: Multipactor discharge is a resonant phenomenon that can be initiated in vacuum under RF excitation, giving rise to charge growth over time. The electron dynamics under such collisionless conditions has been researched by kinetic Monte Carlo and magnetohydrodynamic models in the past. As an alternative, we develop and present studies of a Vlasov equation based numerical model to calculate multipactor susceptibility in common microwave structures [1]. In contrast to kinetic models, utilization of the Vlasov equation permits the continuous treatment of the electron distribution in phase space, thereby capturing all statistical outcomes in a single calculation. To address the computational demand of the Vlasov equation, parallel computing techniques are utilized.

IEEE Conferences

Explosive Emission Cathode Evaluation for a Magnetically Insulated Line Oscillator

Authors: T. Buntin; M. Abide; J. Dickens; A. Neuber; R. Joshi; J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9717481

Abstract: Most high power microwave sources, such as the Magnetically Insulated Transmission Line Oscillator (MILO) being developed at Texas Tech, utilize cold cathodes that generate electrons via explosive emission. These highly emissive cathodes can generate current densities and currents greater than kA/cm2 and 10 kA, respectively which are required for devices that can output RF power greater than 100 MW. Typical explosive emission cathode material includes metal, velvet, carbon fiber, and CsI coated carbon fiber. In order to optimize the MILO performance, we have begun fabricating carbon fiber velvet and comparing the performance with other commercially available materials. Fabrication was done on a manual, mechanical loom using commercially available carbon fiber thread.

IEEE Conferences

Fundamental Study Of Dc And Rf Breakdown Of Atmospheric Air (Vol 26, 123512, 2019)

Authors: Aponte, IA; Esser, B; Shaw, ZC; Dickens, JC; Mankowski, JJ; Neuber, AA

PDF: https://aip.scitation.org/doi/10.1063/1.5119152

Abstract: Radio frequency (RF) breakdown in air at a frequency of particular relevance to ionospheric heating—3.3 MHz, close to the low end of the applicable frequency range—is studied at centimeter-sized gap distances and compared to the literature for small gaps. To establish a reference point, Paschen's early DC breakdown study utilizing two brass spheres of 1 cm radius was replicated following the original procedure and subsequently extended to examine RF breakdown. Various electrode combinations were tested with brass cathodes creating the highest variance in the datasets among DC tests. The greatest variation in RF breakdown arose when either electrode was brass. Gap distances of 1–10 mm were tested for both DC and RF with the slow-rise time (5 mV/μs) RF breakdown occurring at approximately 80% of the DC breakdown value, a value corroborated by Monte Carlo breakdown simulations. Pushing the envelope rise time of the applied RF voltage into the microsecond regime yielded an RF voltage of roughly 20% above the DC breakdown value accompanied by a distinct increase in breakdown amplitude fluctuations. Illuminating the gap electrodes with deep ultraviolet (280 nm and below) minimized the breakdown amplitude fluctuations due to photoemission at the electrodes as expected. Finally, to address the conditions found in real-world geometries with sharp corners or protrusions, RF corona behavior utilizing tungsten needles above a ground plane is measured. The obtained results help us define the operation limits of high-power antennas at 1–10 MHz frequencies.

Journal

High Power 2.85 GHz GaN RF Source for Direct Detection of Multipactor Research

Authors: B. Esser; Z. Shaw; J. C. Dickens; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9717900

Abstract: A pulsed 2.85 GHz RF source design with high average power is presented for use as the principle exciter in an experiment to directly detect multipactor. With a rated output power of 700 W each in long pulse mode (∼ 100 □s), four Cree GaN HEMTs are used to achieve a maximum of 2.8 kW rated output. A fifth HEMT is used to drive the four output devices with approximately 40 W each. A free running VCO with low tuning sensitivity is used which ensures a stable frequency output despite a noisy environment. Buffering and initial amplification is provided by an LNA with a TTL RF switch used to generate the pulses. With a rise time of 35 ns, this switch is fast enough to create reasonably square pulse edges. A microwave amplifier with 45 dB of gain provides the majority of the gain in the system and the power necessary for the final GaN stages, approximately 9 W. An in-line micrometer adjusted, continuously variable attenuator between LNA and TTL switch provides level control.

IEEE Conferences

Investigation of Lightning Attachment Risks to Small Structures Associated With the Electrogeometric Model (EGM)

Authors: William Brooks; David H. Barnett; W. A. Harrison; David Hattz; John Mankowski; James Dickens; Andreas Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9089302

Abstract: A 3-D Monte Carlo-type random walk model was constructed for the assessment of lightning attachment probabilities to small structures. The simulation assumed buildings had a negligible impact on the propagation of lightning. A purely stochastic propagation model based on a previously proposed gas and charged particle diffusion process was employed. The attachment was based on the electrogeometric model in which striking distance is determined by return stroke peak current. This model allows for hundreds of thousands of samples to be evaluated in the window of a few minutes on readily available consumer computing hardware. Using this model, it became possible to enable characterizing building protection as a probability distribution of striking distance. Such was done to provide a deeper understanding of the impact of building protection design choices than is readily available from binary testing. The model was calibrated for minimum input resolution, which is found to be insensitive to variations in step length and moderately insensitive to variations in propagation angle distribution, resulting in normalized errors of less than 15% (rms). A parametric sweep of geometric features was performed for a large (100 m $\times $ 50 m) rectangular building with catenary wire protection. For heights of less than 30 m, lightning was found to bypass protection structures and strike to the building itself at rates that were insensitive to variations in building height. The extent to which the protection may be recessed from the building's perimeter was found to have a significant impact. Variations in building aspect ratio were found to be of limited impact except for cases of extreme aspect ratio where competition with the ground appears to have resulted in much better lightning protection performance.

Journals

Multipactor Thresholds in a Planar Test Cell

Authors: Zachary C. Shaw; Benedikt Esser; James C. Dickens; John J. Mankowski; Andreas A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9520510

Abstract: A planar test cell was designed and implemented to observe the multipactor effect in waveguide structures. This plug and play device allows for multiple geometries to be machined and easily replaced within the test structure. A direct detection method was used to observe the multipactor effect while the upper and lower thresholds were measured for a 2.1 mm gap at 2.85 GHz. While there is an obvious lower limit to multipactor (2 kW), there was no observable upper limit even at powers over 200 kW. This is attributed to the transverse electric field distribution in the dominant TE10 mode which is not taken into account in most multipactor theoretical models.

Conferences

On The Limits Of Multipactor In Rectangular Waveguides

Authors: Shaw, ZC; Silvestre, L; Sugai, T; Esser, B; Mankowski, JJ; Dickens, JC; Neuber, AA

PDF: https://aip.scitation.org/doi/full/10.1063/5.0012833

Abstract: Multipactor in WR-284-like geometries is measured utilizing local and global detection techniques. To emulate conditions one may find in a waveguide filter structure while maintaining the fundamental microwave mode, a standard rectangular waveguide geometry with the reduced waveguide height set to 2.1 or 5.5mm was adopted. Two high power RF sources were used to investigate a large range of input power (few kWs to MWs): a solid state source using GaN HEMTs allowing for larger pulse widths than standard magnetrons (100 mu s as opposed to similar to 4 mu s) and a MW level S-band coaxial magnetron for the high power end. Particular interest was taken in capturing the lower and upper limits of multipactor threshold. Lower multipactor thresholds for finite pulse duration are governed by the appearance of one or more electrons in the multipactor gap during the applied pulse as well as a minimum power (electric field) level that affects a secondary electron emission yield above unity. As shown, such initial electrons(s) may easily be seeded via an external UV source illuminating the gap. However, wall collisions of excited metastable molecules may be another source of electrons, an observation based on the experiment and prior research. A multipactor upper threshold was non-existent in the experiment, even at powers over 200kW within a 2.1mm test gap, which numerically yielded a gap transit time significantly shorter than one half-period of the GHz wave. This is attributed to the electric field distribution within the waveguide structure, which results in the multipactor's spatial position moving to more favorable locations within the test gap.

Journal

Solid-State, High-Voltage Pulse Generator with Microcontroller Control

Authors: J. Williams; D. Barnett; J. Dickens; A. Neuber; J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9717487

Abstract: The development of a solid state high-voltage pulse generator for a spark-gap triggered Marx generator is discussed. The control board features a microcontroller to provide added flexibility and safety. A PIC16 microcontroller and two fiber-optic cables are critical to the design. Optically isolated serial communication between the device and a remote PC is used to control every aspect of the output pulses. This allows for more specific configuration of the pulser and provides remote adjustment of the pulse generator. The design uses the microcontroller's digital I/O pins and SPI/UART peripherals to send and receive operating data over fiber-optic, control the output pulse repetition rate, interface with a digital potentiometer to change the signal amplitude, and activate components that send optically isolated signals to disable/enable the high voltage power supply. In the case of microcontroller failure, the design includes a backup circuit that reconfigures the fiber-optic receiver to trigger an output pulse instead of interpreting UART communication signals. This permits the operator to still trigger the Marx generator remotely in a “single-shot” mode. The successful operation of this device involves configuring the PIC16 to send a 4 kV pulse at repetition rates up to 1 kHz. The flexibility provided by the microcontroller allows customization of several aspects of the output pulse, leaving the design useful in almost any application requiring high voltage pulses.

IEEE Conferences

2019

A Reflex Triode System With Multicavity Adjustment

Authors: D. H. Barnett; K. Rainwater; J. C. Dickens; A. A. Neuber; J. J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=8613091

Abstract: This paper focuses the tunability of a reflex triode virtual cathode oscillator (vircator). The vircator cathode is a bimodal carbon fiber (CF) material, while the anode is polished pyrolytic graphite. These materials have ideal operating characteristics for use within a vircator. These materials have high operating temperatures greater than 1000 K which support large current densities of ~200 A/cm2. A 12-stage, 158-J pulse-forming network (PFN)-based modular Marx generator is used to drive the vircator at 350 kV, 4 kA with ~100-ns pulsewidth at a pulse repetition frequency up to 100 Hz. The 12 stages of the Marx are constructed from a PFN using five, 2.1 nF, high-voltage ceramic capacitors in parallel. The Marx is broken into six modules each containing two stages. The Marx modules are machined from acetyl copolymer commonly called Delrin to provide rigidity and strength. Each Marx module includes air supply lines machined directly into each block, allowing external airlines to connect to each module chamber, rather than every spark gap. After the Marx erects, the energy is used to drive the virtual cathode oscillator (vircator) where subsequent frequency generation is manipulated through a new rectangular waveguide used as the resonant cavity. The new design has three parts of the cavity that can be changed; the bottom plate, back wall, and anode-cathode gap (A-K) distance. Each of these parts moves via linear actuators, two on the bottom plate, one on the A-K gap, and linear bellows for the back wall. The square waveguide cavity is welded into a circular stainless steel sleeve and is housed within a 10-in circular vacuum chamber. The anode is stationary in the vacuum chamber and connects to the Marx generator through a nickel shaft that feeds through the back wall, circular sleeve, and the rectangular waveguide. The anode is pyrolytic graphite, while the cathode is CF. The waveguide bottom plate, back wall, and cathode move around the stationary anode. This allows the height of the resonant cavity and the back wall distance from A-K gap to be independently changed of each other.

IEEE Journals

Calculations Of Multipactor Growth In Rectangular Waveguides

Authors: H. K. A. Nguyen; J. Mankowski; J. C. Dickens; A. A. Neuber; R. P. Joshi

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=8599158

Abstract: Multipactor growth in rectangular waveguides is probed based on a kinetic approach. Unlike most studies relying on the Vaughan model, a probabilistic approach for random multiple secondary particle emissions is used. Spread in electron emission velocities, the angular dependence of secondary emission yields, and an external radio frequency (RF) driving field due to a TE10 mode, were all built in. The calculations predict the secondary emission yield for copper, probe the population growth dynamics, and obtain the susceptibility diagram. Despite a maximum field at the waveguide center from the RF excitation, maximum electron densities are predicted at locations symmetrically displaced from the center. The secondary electron yield (SEY) characteristics, its local maxima, and the role of oblique incident angles, collectively lead to multipactor finding its place at off-center locations.

Journal

Compact Marx Generator to Drive a Low-Impedance MILO

Authors: T. Buntin; M. Abide; D. Barnett; J. Dickens; A. Neuber; R. Joshi; J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9009681

Abstract: A low-impedance MILO is being developed at Texas Tech University, and a compact Marx generator was designed to drive it. The target design goals of the Marx are an output voltage greater than 500 kV and an output current greater than 40 kA. Risetime needs to be sub 150 ns and the pulsewidth must be greater than 100 ns. These performance goals were determined from PIC simulation of the MILO such that an RF efficiency (>10%) and RF peak power (> 1 GW) can be achieved. Tests using smaller 3 and 4 stage Marx generators with the same topology as the final design were used to determine a per-stage inductance of approximately 120 nH. From this derived inductance, multiple configurations were simulated to decide upon the ideal design for the desired performance goals. From these simulations, an 18-stage Marx with 2 capacitors per stage was chosen as the most optimal design, and from simulations into a 12 Ohm load a number of the criteria can be met with this configuration. The simulated peak voltage and current are 570 kV and 48 kA, respectively, while pulse risetime and pulsewidth are 170 ns and 540 ns, respectively. The designed Marx is being experimentally validated to confirm the findings of the simulation, firing into an approximately 12 Ohm water load to represent the low-impedance MILO that is being designed.

IEEE Conferences

Direct Observation Of Electrons In Microwave Vacuum Components

Authors: Shaw, ZC; Garcia, A; Powell, M; Dickens, JC; Mankowski, JJ; Neuber, AA

PDF: https://aip.scitation.org/doi/10.1063/1.5089764#:~:text=Electron%20multipliers%20ABSTRACT%20Apparatus%20which%20is%20used%20to,GHz%20with%20up%20to%20approx.%201%20MW%20power.

Abstract: Apparatus which is used to directly observe electrons in microwave vacuum components was designed and implemented into a WR-284 like waveguide operated at 2.85 GHz with up to approx. 1 MW power. To generate desired electric field levels for driving secondary emission, the waveguide structure is manipulated by reducing the test section height to 6 mm from the standard WR-284 rectangular waveguide height of 34 mm. Both test and standard sections were operated in the dominant TE10 mode. A 1 mm aperture was cut into the broadside wall of the waveguide section enabling a portion of electrons in the waveguide to enter a properly biased electron multiplier tube mounted atop of the test section. Waveforms are presented showing the direct measurement of electrons, providing a local detection method with nanosecond temporal resolution. Future work will incorporate the test setup for multipactor studies. Published under license by AIP Publishing.

Journal

Fast SiC Switching Limits for Pulsed Power Applications

Authors: L. Collier; T. Kajiwara; J. Dickens; J. Mankowski; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=8770271

Abstract: Solid-state semiconductor switches are emerging as an attractive choice for the fast switching of compact, repetitive, and pulsed power systems. In particular, the high voltage and fast switching capabilities of SiC MOSFETs are well suited for many applications when appropriately gated. For instance, the turn-on and turn-off characteristics of such devices are strongly dependent on the gate driving circuitry. Traditional commercial gate drivers, typically utilizing push-pull or totempole driving topologies, are often not well suited for fast, high current switching with rise times on the order of 10-20 ns, as the driving performance is highly dependent on the combined RLC characteristics of the driving circuitry and the switching device. The proposed gate drive topology utilizes a current-carrying inductor to rapidly charge the MOSFET gate-source capacitance. A high-voltage inductive kick generates the necessary potential to drive the inductor current into the gate through the parasitic gate impedance. As the energy stored in the drive inductor is continuously variable, it can be adjusted such that the gate voltage settles to a lower value, typically 20 V, after the initial kick to prevent excessive gate-source overvoltage. With an inductive drive current of ~23 A, a peak dI/dt of 25 kA μs-1 was achieved for the tested bare SiC MOSFET die. Additionally, a peak dI/dt of 13 kA μs-1 was achieved with the TO-247 packaged device.

IEEE Journals

Fundamental Study Of Dc And Rf Breakdown Of Atmospheric Air

Authors: Aponte, IA; Esser, B; Shaw, ZC; Dickens, JC; Mankowski, JJ; Neuber, AA

PDF: https://aip.scitation.org/doi/10.1063/1.5119152

Abstract: Radio frequency (RF) breakdown in air at a frequency of particular relevance to ionospheric heating-3.3 MHz, close to the low end of the applicable frequency range-is studied at centimeter-sized gap distances and compared to the literature for small gaps. To establish a reference point, Paschen's early DC breakdown study utilizing two brass spheres of 1 cm radius was replicated following the original procedure and subsequently extended to examine RF breakdown. Various electrode combinations were tested with brass cathodes creating the highest variance in the datasets among DC tests. The greatest variation in RF breakdown arose when either electrode was brass. Gap distances of 1-10 mm were tested for both DC and RF with the slow-rise time (5 mV/mu s) RF breakdown occurring at approximately 80% of the DC breakdown value, a value corroborated by Monte Carlo breakdown simulations. Pushing the envelope rise time of the applied RF voltage into the microsecond regime yielded an RF voltage of roughly 20% above the DC breakdown value accompanied by a distinct increase in breakdown amplitude fluctuations. Illuminating the gap electrodes with deep ultraviolet (280 nm and below) minimized the breakdown amplitude fluctuations due to photoemission at the electrodes as expected. Finally, to address the conditions found in real-world geometries with sharp corners or protrusions, RF corona behavior utilizing tungsten needles above a ground plane is measured. The obtained results help us define the operation limits of high-power antennas at 1-10 MHz frequencies.

Journal

Geometry tuning of an electrically small antenna for ionospheric heating

Authors: B. Esser; J. J. Mankowski; J. C. Dickens; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=8789007

Abstract: A modification of a previously introduced electrically small antenna is presented with tuning methods for continuous band coverage for ionospheric heating (∼3–10 MHz). Consisting of a small loop antenna inductively coupled to a capacitively loaded loop (CLL), the design may be tuned ±50% of the center of the band by simply adjusting the capacitance of the CLL. Abandoning the use of lossy materials for tuning such as solid dielectrics or ferrites, the antenna is greater than 80% efficient across its tuning range. A tenth scale prototype with electromechanical geometry tuning is tested for frequency range and tuning capability especially at the low-frequency end where port reflection losses tend to dominate. Tuning of the small loop antenna-CLL coupling is used to mitigate this matching issue, which was demonstrated on the physical antenna model. Experimentally, a tuning range of 33.5–117.5 MHz is achieved with low reflection achievable across the range.

AGU Journals

High Field RF Breakdown of Pressurized SF6

Authors: M. Powell; Z. Shaw; J. C. Dickens; J. J. Mankowski; A. A. Neuber; C. Scribner

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9009615

Abstract: Pure N2 and SF6, as well as their mixtures, are evaluated for high electric field breakdown tested at pressures ranging from 750 torr to 1650 torr at 2.85 GHz. Previous research concerning the breakdown characteristics of pressurized SF6 and SF6 mixtures at S-Band frequencies is limited, likely due to the high electric fields required to breakdown pressurized SF6. A stepped impedance transformer is used in conjunction with a traveling wave resonator to obtain the high electric field amplitudes necessary to break down the gases. Starting with the output from a 3.5 MW coaxial magnetron the electric field amplitude in the test piece at the center of the stepped impedance transformer yielded a maximum of about 150 kV/cm RMS field. Using Pure SF6 as a baseline, the measured breakdown field shows a mostly linear dependence upon pressure in a range from 750 torr to 1350 torr, while some leveling out tendency is observed at pressures greater than 1350 torr. Since pure N2 exhibits a much lower breakdown threshold, ~ 60%, compared to pure SF6, mixing the two gases also results in a lower effective breakdown threshold; however, the reduction in the electric field breakdown threshold is not strictly proportional. For example, a 60/40 SF6 to N2 mixture resulted in a 90% breakdown field while a 20/80 mixture still yielded about 80% in the high-pressure regime.

IEEE Conferences

High-Speed Imaging of Polymer-Bonded Explosives under Mechanical Stresses

Authors: R. Lee; A. Hewitt; R. Clark; H. Hudyncia; T. Buntin; D. Barnett; J. C. Dickens; J. J. Mankowski; W. A. Harrison; E. Tucker; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9009758

Abstract: The impact of mechanical stresses on polymer bonded high explosives, HE, is investigated. High-Speed photography in the visible spectrum, VIS, as well as mid-wave infrared (MWIR) of HE during small diameter drilling and controlled skidding is presented. Controlled drilling into the HE enables recording the size and temperature of shavings under varying feed and speeds. Even at very high drill speeds, the HE phase transition temperature of approx. 180 degree Celsius is rarely exceeded. The MWIR signals radiated are recorded with FLIR's X6901sc High-speed MWIR camera, which uses InSb technology, with a wavelength range from 3.0 to 5.0 μm, and up to 1,004 fps at a resolution of 640 × 512 in the temperature range of interest. High-speed recording in the visible is obtained utilizing Phantom's VEO710s high-speed camera at a higher frame rate of 7,400 fps at a resolution of 1280 × 800 in the VIS. Observing the HE-grit interaction in the MWIR poses a great challenge, for IR is blocked by many glasses.

IEEE Conferences

Ignition Mechanisms of Polymer Bonded Explosives During Drilling

Authors: R. Clark; R. J. Lee; A. T. Hewitt; T. Buntin; D. Barnett; J. C. Dickens; W. A. Harrison; E. Tucker; J. J. Mankowski; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9009974

Abstract: The drilling behavior of polymer bonded high explosives (HE) is investigated by varying drilling parameters and analyzing resultant forces and thermal response. A modified drill press enables remote operation and precise control of cutting speed, feed, and depth. To acquire temperature at the cutting interface a K-Type thermocouple is inserted in the coolant holes of thru-coolant drill bits and epoxied flush with the drill's flank face, which yielded a sensing accuracy of ±1°C and a resolution of 0.48°C. Cutting forces and torques are acquired with a sampling speed of up to 2,000 Hz. The comparison of downward directed forces across cutting operations is indicative of which speed and feed rate combinations limit excessive stressing of the HE, while cutting axis torques give indication in the case of drilling obstructions such as insufficient chip clearance. Drilling conditions in excess of the existing US DOE-STD-1212-2012 limitations are tested to determine safe but efficient machining limits for these materials. Drilling speed, feed rate, and peck depth are varied for drilling cycles with a 5 mm diameter drill bit, and further cycles are performed to determine the effect of increasing cut diameter. In peck drilling, clearance of chip from the drill flute is crucial and governs the drill's temperature rise.

IEEE Conferences

Improving Fast SiC MOSFET Switching Using an Inductive Gate Drive Approach

Authors: M. LaPointe; L. Collier; T. Kajiwara; J. Dickens; J. Mankowski; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9009986

Abstract: An innovative gating scheme for wide bandgap semiconductor switches is investigated to fully exploit recent advances of SiC MOSFET properties in hold-off voltage (from single digits to tens of kV) and low on-state resistance (tens of mΩ). Robust gate driving techniques are required to achieve fast risetimes on the order of 10-20 ns. Further, due to the high dI/dt, and subsequent inductive kickback, parasitic inductance may drastically affect the performance of commercially available totem-pole gate drivers. Further, traditionally packaged MOSFETs exhibit additional degradation of switching characteristics due to the introduction of parasitics primarily due to their lead geometry.

IEEE Conferences

Low-Impedance S-Band MILO

Authors: M. Abide; T. Buntin; D. Barnett; J. Dickens; R. Joshi; A. Neuber; J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9009939

Abstract: The development of a low-impedance magnetically insulated transmission line oscillator (MILO) driven by a compact Marx generator developed by Texas Tech University is discussed. The goals of the project aim to develop a MILO operating within the S-Band that can provide an RF peak output power of greater than 1 GW with greater than 10% efficiency. The device design followed a set of base design equations that were applied to a CST Studio Suite (CST) for a Particle-in-Cell, PIC, simulation to model the MILO. These simulation results then inform changes to the model to optimize the prospective performance of the device. The simulations were developed to account for realistic material properties that were then applied to critical surfaces of the device. Additionally, a circuit simulation was included to model a Marx generator feeding the input of the MILO to simulate the eventual experimental setup. Current results verify an expected RF peak power of approximately 4.5 GW at 2.5 GHz operating in the TM01 mode when excited with an input signal that has a peak voltage of 600 kV while providing a peak current of 58 kA. The simulation confirms the design should perform within these constraints.

IEEE Conferences

Magnetic Field Diffusion in Medium-Walled Conductors

Authors: Landon Collier; Tyler Buntin; James Dickens; John Mankowski; John Walter; Andreas Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8561207

Abstract: The diffusion of transient magnetic fields through the walls of a hollow conductive shell is an important phenomenon of interest throughout a variety of pulsed power applications. Basic solutions do exist for cylindrical geometries in the limiting case that the skin depth is much larger than the wall thickness; however, in many pulsed applications, the transient skin depth is often similar to the conductor thickness. As the underlying thin-wall assumption begins to breakdown, the production of complex eddy current distributions in the conductor walls results in deviation from these simplified analytical solutions of the diffused field. Precise calculation of these current distributions is essential for many applications including inductive shielding and magnetic field diagnostics near conductors. Electromagnetic simulations using the finite-element method provide a more accurate picture of the diffusion process in this regime. A high magnetic field testbed facilitates measurement of the diffused fields in order to verify simulation accuracy. The effect of material conductivity, wall thickness, and conductor geometry on the diffusion process is examined.

Journals

Microsecond Fast, 100 kV Modular Pulse Charger

Authors: T. Klein; A. Neuber; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9009641

Abstract: A pulse charger module was designed and tested for use in a larger system Each pulse charger module is powered with a 12 V Lithium-ion battery and set to charge a nF sized capacitor up to 100 kV in less than 10 μs. This is achieved by initially charging a μF sized capacitor to 3 kV, then switching a thyristor to discharge this capacitor into a step-up pulse transformer to charge the load capacitor. A PIC 18F26K80 8-bit microcontroller in each pulse charger module will be used to control the module, communicate with other modules and a computer, and monitor voltages. The modules are programmed to automatically detect the total number of modules well as communication delays between each module at startup, allowing for synchronous triggering and induvial identification and control. Each module is kept in a low power mode when not in use, and fiber optic communication is used throughout such that electrical isolation between modules and the master computer is ensured.

IEEE Conferences

Model Evaluations Of Surface Modification By Energetic Incident Carbon Atoms On Graphene Coated Copper Electrodes

Authors: Qiu, X; Mankowski, J; Dickens, JC; Neuber, AA; Joshi, RP

PDF: https://aip.scitation.org/doi/10.1063/1.5056766

Abstract: Thin nanoscale coating of metal electrodes by graphene promises to be a useful approach for suppressing the secondary electron yield and potential multipactor. Recent calculations showed reductions by as much as 50% for graphene over copper electrodes for energies below 125 eV, with results in good agreement with experimental data. Here, the resistance to possible degradation of this structure, in response to incoming atomic projectiles, is gauged based on molecular dynamics simulations. Our results for surface irradiation by carbon atoms (as an example) on nanoscale graphene coatings indicate a defect threshold of about 35 eV, lower surface damage for thicker layers, negligible sputtering, and defects less than 6 angstrom in dimension for energies up to 300 eV. The electrode structure is shown to be robust with better resistance to damage than metal alone. Published under license by AIP Publishing.

Journal

Numerical studies into the parameter space conducive to "lock-on" in a GaN photoconductive switch for high power applications

Authors: A. R. Chowdhury; S. Nikishin; J. Dickens; A. Neuber; R. P. Joshi; R. Ness

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=8662228

Abstract: Time-dependent photocurrent response in semi-insulating GaN is simulated with a focus on the "Lock-On" phenomenon. A one-dimensional, time-dependent model based on drift-diffusion theory is used. The model was first tested for GaAs and shown to yield good agreement with data, before applying it to GaN simulations. The main findings are that compensated GaN with deeper traps nearer the midgap at higher densities, and/or multiple levels around the mid-gap would aid in driving the PCSS towards Lock-On. The initial average threshold field for Lock-On in GaN is predicted to be around 150 kV/cm, though this would be strongly dependent on the trap parameters of a sample.

IEEE Journals

Packaging and Evaluation of 100 kV Photoconductive Switches

Authors: J. Culpepper; A. Miller; A. Neuber; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9009753

Abstract: It is desired to integrate a photoconductive semiconductor switch (PCSS) capable of holding off and switching 100 kV into a package with small parasitic inductance such that sub-nanosecond rise time is still achievable at current amplitudes of hundreds of amperes. A GaAs based PCSS is utilized, which makes it necessary to address the filamentary nature of the current, which may lead to a shortening of device lifetime. In order to design a practical package, COMSOL based 2D electric field simulations have been utilized to aid in shaping the field between the PCSS semiconductor, the electrodes, and the high voltage encapsulant. To deal with the unavoidable high field stresses in the small package, the switch is brought to voltage within a few microseconds only, and then closed. Thus, keeping the duration of voltage stress very short, and the risk of self-triggering due to leakage current low.

IEEE Conferences

Statistics and Propagation Modeling of Atmospheric Lightning

Authors: W. Brooks; D. Barnett; J. J. Mankowsi; J. C. Dickens; A. A. Neuber; W. A. Harrison; D. Hattz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9009756

Abstract: A stochastic model of downward lightning propagation and attachment was developed based on existing models of the propagation of a negative leader as a gas diffusion problem. Attachment was modelled using the rolling sphere concept. The resulting simulation enables Monte Carlo methods of assessing the efficacy of geometric lightning protection schemes. Protection afforded to a 100 m by 50 m building was investigated to elucidate the relative impact of selected protection configuration parameters. The results were found to be insensitive to variations in building height for configurations of less than 30 m. Variation in footprint area found protection for large buildings generally exhibits worse performance relative to smaller structures. This trend was examined in detail for a regular, square arrangement of lightning rods. Variation in building aspect ratio was found to have a pronounced impact on protection performance and is attributed to non-preferential striking to the available geometries. A method for arriving at the expected rate of a given building being stuck is outlined which expects the aforementioned structure to be struck at a rate of about four times per 10 000 years.

IEEE Conferences

2018

A 2 KW, 2.85 GHZ Multipactor RF Source Utilizing Depletion Mode GaN HEMTs

Authors: B. Esser; Z. Shaw; J. C. Dickens; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9575563

Abstract: A pulsed RF source for multipactor research capable of providing 2 kW at 2.85 GHz to a multipactor test cell is described utilizing state-of-the-art GaN HEMTs from Cree/Wolfspeed and integrated GaN amplifier from Qorvo/Tri-Quint. A Mini-Circuits ZX95-2920CA+ VCO is used as the signal generator with low phase noise and modulation capable with a bandwidth of 55 MHz. An inline attenuator provides the operator power control in the range of approximately 42 to 64 dBm (16 to 2800 W). A high-speed RF switch creates a 100-microsecond pulse with a rise time of 25 ns and a typical switching time of 35 ns. A single Tri-Quint TGA2585-SM provides the majority of the gain in the system, 32 dB, and the necessary power for the final output stage (6 W). Four CGHV31500F amplifiers operating in parallel comprise the output stage providing the bulk of the power needed, 500 W each for a total of 2 kW with 12.5 dB gain each, with a single unit providing the necessary input power before splitting to the four finals (50.5 dBm, ~ 112 W). A custom PCB was designed to properly bias the GaN stages and prevent device failure due to improper bias sequencing. Custom power splitters and combiners had to be used due to the high-power levels being considered with directional couplers on the output to monitor output (forward) power and reflected (reverse) power during operation. This will provide valuable insight into characteristics of the plasma cloud generated during the multipactor event.

IEEE Conferences

Assessing The Role Of Trap-To-Band Impact Ionization And Hole Transport On The Dark Currents Of 4H-Sic Photoconductive Switches Containing Deep Defects (Vol 120, 245705, 2016)

Authors: Chowdhury, AR; Dickens, JC; Neuber, AA; Joshi, RP

PDF: https://aip.scitation.org/doi/10.1063/1.4972968

Abstract: Simulation studies of the electrical response characteristics of 4H-SiC switches containing traps are reported in the absence of photoexcitation. The focus is on trap-to-band impact ionization and the role of hole injection from the anode. Simulations show that hole-initiated ionization can be more important than the electron-initiated process. The results also underscore the role of hole injection at the high applied voltages. Our one-dimensional, time-dependent model yielded reasonable agreement with measured current-voltage data spanning over three orders of magnitude, but only when impact ionization was taken into account. Finally, the simulations predicted undulations in the device conduction current density with respect to time, due to the dynamic interplay between impact ionization, spatial electric field values, and occupancies of the trap levels.

Journal

Assessing the Influence of Secondary Electron Emission Characteristics on Multipactor in Rectangular Waveguides

Authors: Hieu K. A. Nguyen; John Mankowski; James C. Dickens; Andreas A. Neuber; Ravi P. Joshi

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9575287

Abstract: Multipactor in a rectangular waveguide is studied using numerical simulations. Particular attention is given to the secondary electron emission characteristics including their energy spectrum (hence velocity spread) and angular distribution. Elastically scattered, rediffused and true secondary electrons are all comprehensively included based on the Furman-Pivi model [1] for the TE10 mode. The focus is on small waveguides and lowest order resonance conditions.

Conferences

CST Particle-In-Cell Modeling Of A Tunable Reflex-Triode Vircator

Authors: D. H. Barnett; A. A. Neuber; J. C. Dickens; J. J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=8936727

Abstract: This study serves to describe three-dimensional particle-in-cell (PIC) simulations of a tunable reflex-triode virtual cathode oscillator (vircator). Experimental data from the compact hard-tube reflex-triode vircator developed at Texas Tech University (TTU) is used to validate simulated results. The vircator developed at TTU is capable of burst-mode operation at pulse repetition rates (PRFs) up to 100 Hz for a period of one second. A pulse energy of 158 J drives the vircator, and 600 kV (open circuit) pulse forming network (PFN) based Marx generator. The vircator is comprised of a bimodal, carbon fiber cathode and a pyrolytic graphite anode, with the ability to quickly change the distance between the anode-cathode (A-K) gap, back wall distance, and bottom plate distance between experiments. The PIC simulations have been performed using CST PIC Solver, by Dassault Systemes. The models detail virtual cathode formation and the subsequent extraction of radiated microwave power for a variety of cavity geometries. A working three-dimensional, relativistic, electromagnetic, particle-in-cell model of a vircator allows for quick, predictive results relative to building an experimental setup. The model is used to determine the necessary driving voltages, A-K gap distances, and cathode current densities to extract microwave radiation at a desired. Simulated results aid in identifying mode contributions. Voltage, current, and microwave data are presented and compared against experimental results at different operating conditions.

IEEE Conferences

Calculations Of Secondary Electron Yield Of Graphene Coated Copper For Vacuum Electronic Applications

Authors: Nguyen, HKA; Mankowski, J; Dickens, JC; Neuber, AA; Joshi, RP

PDF: https://aip.scitation.org/doi/10.1063/1.5019360

Abstract: The suppression of secondary electron yield (SEY) which can possibly lead to multipactor is an important goal for several applications. Though some techniques have focused on geometric modifications to lower the SEY, the use of graphene coatings as thin as a few monolayers is a promising new development that deserves attention either as a standalone technique or in concert with geometric alterations. Here we report on Monte Carlo based numerical studies of SEY on graphene coated copper with comparisons to recent experimental data. Our predicted values are generally in good agreement with reported measurements. Suppression of the secondary electron yield by as much as 50 percent (over copper) with graphene coating is predicted at energies below 125 eV, and bodes well for multipactor suppression in radio frequency applications. (c) 2018 Author(s).

Journal

Developing Safe Lathing Parameters For Pbx 9501

Authors: Woodrum, RB; Barnett, DH; Dickens, JC; Neuber, AA

PDF: https://onlinelibrary.wiley.com/doi/10.1002/prep.201700285

Abstract: This paper presents the work performed on dry-lathing PBX 9501 to gather and analyze cutting force as well as temperature data during the machining process. The data is compared to present USA federal-regulation-constrained machining limits of high explosives. The effects of machining parameters depth of cut, surface meters per minute, and feed per revolution on cutting force and cutting interface were evaluated. Cutting tools of tip radius 0.013cm and 0.127cm were tested to determine the effect of the tool shape on the machining process. Empirically, a pronounced dependence of the maximum tool temperature on the depth of cut and surface meters per minute was found, while the dependence on the feed per revolution was found much weaker. It is elucidated that rapid, shallow cuts optimize machining time for a billet of PBX 9501 while minimizing temperature increase and cutting force.

Journal

Electrically Small Antenna Design for Transportable Ionospheric Heating

Authors: B. Esser; J. C. Dickens; J. J. Mankowski; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9575799

Abstract: Ionospheric Heating, traditionally performed utilizing large fixed location arrays, while effective, limits research efforts to those fixed locations. As one may envision, a more compact transportable array will provide additional research opportunities at latitudes previously unexplored. For instance, closer to the equator where the Earth's magnetic field is primarily parallel to the ground. An electrically small inductively coupled antenna is considered for its suitability in such an array. A Small or Semi Loop Antenna (SLA) inductively couples to a Capacitively Loaded Loop (CLL) providing high efficiency and natural 50 $\Omega$ port matching. The CLL, of hinged petal design, consists of a large parallel plate capacitor, and half cylinder inductive sections which are hinged at the base to allow for tuning in the range of ionospheric heating (3 - 10 MHz) with a plate included angle of 0 - 16°. A prototype antenna was designed and evaluated at 1/10th scale - for ease of research efforts - with tuning range of 30 - 100 MHz including capability of tuning the coupling between SLA and CLL to achieve good source matching across the tuning range, particularly at the low and high ends. This tuning method may also be used to compensate for mutual impedance effects in array operation, improving array performance. A gain of approximately 5 dBi is observed when placed upon a sufficiently large ground plane. Tuning of the antenna prototype is achieved via stepper motor driven system to remotely adjust both the CLL and SLA angles continuously.

IEEE Conferences

Fundamental Study Of Atmospheric Rf Breakdown At 3.3 MHz

Authors: I. A. Aponte; B. Esser; Z. Shaw; J. C. Dickens; J. J. Mankowski; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9575875

Abstract: RF breakdown at a frequency of particular relevance to ionospheric heating - 3.3 MHz, close to the low end of the applicable frequency range - is studied at centimeter sized gap distances and compared to literature for small gaps. Paschen's famous DC breakdown study utilizing two brass spheres of radius 1 cm was recreated following the original procedure, from which the data was used to compare to a study of RF breakdown. Through testing it was found that brass as an electrode material exhibits a large standard deviation in breakdown voltage and as such stainless-steel Bruce profile uniform electric field electrodes were substituted. Steel's resistance to surface ablation provided for extremely low standard deviation of measurements and hence good repeatability. Additionally, unlike brass, steel is not contaminated through reaction with gaseous elements such as carbon, oxygen and nitrogen. Electrodes were polished to remove any field enhancements and cleaned of polishing compound such that dielectric inclusions were largely avoided.

IEEE Conferences

High Power RF Breakdown of Pressurized SF6

Authors: M. Powell; Z. Shaw; J. C. Dickens; J. Mankowski; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9575375

Abstract: The design and implementation of an experimental setup are demonstrated for the breakdown testing of pressurized $\text{SF}_{6}$ (1–3 atm) at 2.85 GHz. Sulphur hexafluoride $(\text{SF}_{6})$ is a common insulating gas used to mitigate breakdown in high power microwave systems. While this gas is known for its high dielectric strength, available data for the breakdown of pressurized SF 6 and $\text{SF}_{6}$ mixtures at S- Band frequencies is limited. The obtained breakdown characteristics are compared to mixtures of $\text{SF}_{6}$ and Nitrogen $(\mathrm{N}_{2})$ for similarities in breakdown fields in a pressurized environment.

IEEE Conferences

Investigation of GaN Photoconductive Semiconductor Switches

Authors: Nicholas A. Wilson; Jared A. Culpepper; Vladimir Kuryatkov; Matthew Gaddy; James C. Dickens; Sergey Nikishin; Richard Ness; Andreas A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9575438

Abstract: The suitability of commercially available wide bandgap GaN material for the fabrication of photoconductive semiconductor switches, PCSS, was investigated. A variety of PCSSs were fabricated utilizing diverse GaN samples, which were shown to exhibit significantly diverse physical properties. That is, sample characterization techniques such as cathodoluminescence (CL), photoluminescence (PL), secondary ion mass spectrometry (SIMS), Current-Voltage behavior, and scanning electron microscopy (SEM) were applied to characterize the samples prior to processing.

Conferences

Lock-On Physics In Semi-Insulating Gaas: Combination Of Trap-To-Band Impact Ionization, Moving Electric Fields And Photon Recycling

Authors: Chowdhury, AR; Dickens, JC; Neuber, AA; Ness, R; Joshi, RP

PDF: https://aip.scitation.org/doi/10.1063/1.5013248

Abstract: The time-dependent photoconductive current response of semi-insulating GaAs is probed based on one-dimensional simulations, with a focus on the lock-on phenomenon. Our results capture most of the experimental observations. It is shown that trap-to-band impact ionization fuels local field enhancements, and photon recycling also plays an important role in pushing the device towards lock-on above a 3.5 kV/cm threshold field. The results compare well with actual data in terms of the magnitudes, the rise times, and the oscillatory behavior seen at higher currents. Moving multiple domains are predicted, and the response shown depended on the location of the photoexcitation spot relative to the electrodes. Published by AIP Publishing.

Journal

Monte Carlo Analysis Of Field-Dependent Electron Avalanche Coefficients In Nitrogen At Atmospheric Pressure (Vol 24, 124501, 2017)

Authors: Nguyen, HK; Mankowski, J; Dickens, JC; Neuber, AA; Joshi, RP

PDF: https://aip.scitation.org/doi/10.1063/1.5004995

Abstract: Calculations of electron impact ionization of nitrogen gas at atmospheric pressure are presented based on the kinetic Monte Carlo technique. The emphasis is on energy partitioning between primary and secondary electrons, and three different energy sharing schemes have been evaluated. The ionization behavior is based on Wannier's classical treatment. Our Monte Carlo results for the field-dependent drift velocities match the available experimental data. More interestingly, the field-dependent first Townsend coefficient predicted by the Monte Carlo calculations is shown to be in close agreement with reported data for E/N values ranging as high as 4000 Td, only when a random assignment of excess energies between the primary and secondary particles is used.

Journal

Multipactor and Breakdown Susceptibility and Mitigation in Space-Based RF Systems

Authors: J. P. Verboncoeur; N. Behdad; J. H. Booske; J. C. Dickens; R. M. Gilgenbach; M. Gilmore; N. M. Jordan; R. P. Joshi; Y. Y. Lau; J. Mankowski; D. Morgan; A. A. Neuber; S. Portillo; E. Schamiloglu; P. Zhang

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9575295

Abstract: Multipactor onset, growth, associated space charge effects, and transition to ionization breakdown due to ambient or desorbed gases represent key stages of single and multifrequency RF -driven phenomena that inhibit performance in space-based and terrestrial vacuum electronics devices. Performance degradation through space charge detuning and interference with gain is expected for medium duration pulses, and ion generation and damage for longer pulses. In this research, combined theoretical, computational, and experimental approaches are applied.

IEEE Conferences

Observation of Multipactor Effects in Space-Based RF Environments

Authors: Z. Shaw; B. Esser; J. C. Dickens; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9575386

Abstract: An experimental setup was designed and implemented for the study of the multipactor effect in a rectangular waveguide under high vacuum. The experiment and test piece were constructed using WR 284 waveguide sections operating at S- Band frequencies. Multipactor effects are to be detected via an Electron Multiplier Tube (EMT). The test setup includes sections of standard WR 284 waveguide which will be in line with a custom test piece. Design of the test setup incorporates a standard piece of waveguide with a custom steel collar which can be used to insert different tapers, and even periodic structures into the hollowed out broadside wall. A solid state RF transmitter with 2.8 kW peak power and a center frequency of 2.85 GHz is used to inject an RF signal into the test section.

IEEE Conferences

On the Wave Propagation Through Apertures

Authors: Z. Shaw; A. Hewitt; J. C. Dickens; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=9575943

Abstract: A multi -channel phased array is used to synthesize signals of varying frequencies through apertures in EM shielded structures. Bipolar impulses with a GHz frequency spectrum are emitted from multiple antennas and used as basis functions to pass through the aperture and undergo constructive and destructive interference at a specific point in space. Experiments based on a small antenna array demonstrate that this technique enables synthesizing a below GHz signal (~ 400 to 800 MHz) in a shielded volume with an open aperture size that would heavily attenuate a direct sub-GHz electromagnetic wave. While the experimental results demonstrate that this technique is effective at UHF frequencies, it is certainly not limited to this frequency band.

IEEE Conferences

Structural, Morphological, Optical And Electrical Properties Of Bulk (0001) Gan:Fe Wafers

Authors: Gaddy, M; Kuryatkov, V; Meyers, V; Mauch, D; Dickens, J; Neuber, A; Nikishin, S

PDF: https://link.springer.com/article/10.1557/adv.2018.234

Abstract: Characterization of three vendor's bulk semi-insulating GaN:Fe wafers, grown by either hydride vapor phase epitaxy or the ammonothermal method, was performed using: scanning electron microscopy, secondary ion mass spectroscopy, high resolution X-ray diffraction, cathodoluminescence, photoluminescence, and high voltage testing. Although the Fe doping level is significantly different for each growth method, both are promising for the fabrication of PCSS devices operating in the lock-on mode.

Journal

Tunable, electrically small, inductively coupled antenna for transportable ionospheric heating

Authors: Benedikt Esser; Daniel Mauch; James Dickens; John Mankowski; Andreas Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8679867

Abstract: An electrically small antenna is evaluated for use as the principle radiating element in a mobile ionospheric heating array. Consisting of a small loop antenna inductively coupled to a capacitively loaded loop, the electrically small antenna provides high efficiency with the capability of being tuned within the range of ionospheric heating. At a factor 60 smaller in area than a High-Frequency Active Auroral Research Program element, this antenna provides a compact, efficient radiating element for mobile ionospheric heating. A prototype antenna at 10 MHz was built to study large-scale feasibility and possible use with photoconductive semiconductor switch-based drivers. Based on the experimental study, the design has been extrapolated to a small 6 × 4 array of antennas. At a total power input of 16.1 MW this array is predicted to provide 3.6-GW effective radiated power typically required for ionospheric heating. Array cross talk is addressed, including effects upon individual antenna port parameters. Tuning within the range of ionospheric heating, 3–10 MHz, is made possible without the use of lossy dielectrics through a large capacitive area suited to tune the antenna. Considerations for high power operation across the band are provided including a method of driving the antenna with a simple switcher requiring no radio frequency cabling. Source matching may be improved via adjustment of the coupling between small loop antenna and capacitively loaded loop improving |S11| from −1 to −21 dB at 3 MHz.

Journals

2017

160 J, 100 HZ repetition rate, compact Marx generator and high power microwave system

Authors: D. H. Barnett; K. Rainwater; J. C. Dickens; A. A. Neuber; J. J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=8291279

Abstract: This paper presents the electrical and mechanical hardware considerations of a compact, 160 J modular pulse forming network (PFN) Marx generator used to drive a high-power microwave (HPM) source that is a time variant load at a PRF of 100 Hz. The modular Marx generator is designed to produce an open-circuit output voltage of 600 kV from a 50 kV source using twelve stages. Each stage of the Marx was constructed from a PFN fashioned from five, 2.1 nF, high voltage capacitors in parallel. Each Marx module was machined out of acetyl copolymer or Delrin© to provide optimal strength, rigidity, and a dielectric constant that closely matches transformer oil. These Marx modules include air supply lines that are machined directly into each block of Delrin© allowing airlines to connect to each module chamber rather than every spark gap. Each module has two electrode inserts placed into the sealed pressure vessel contained within the module. After the Marx erects, the energy is directed into the virtual cathode oscillator (vircator) where subsequent frequency generation is manipulated through a rectangular waveguide contained within a new resonator cavity design. The new design allows the bottom wall, back wall, and anode cathode gap to be moved by two linear actuators, a linear bellows, and another linear actuator, respectively. The cavity is contained within a 10-inch circular vacuum chamber with a round stainless steel sleeve running from the back wall to the linear bellows. Contained within the round sleeve is a rectangular waveguide where the bottom wall and the cathode are housed. The anode is connected to the Marx generator via a nickel shaft that feeds through the back wall into the circular sleeve and into the rectangular waveguide. The anode made from pyrolytic graphite, remains stationary while the bottom wall, and carbon fiber velvet cathode move relative to its position. The benefit of this design is the height and depth of the cavity resonator can be controlled independently of each other while still allowing the A-K gap to be manipulated on its own.

IEEE Conferences

A Software Controllable Modular Rf Signal Generator With Multichannel Transmission Capabilities

Authors: Shaw, Z; Feilner, W; Esser, B; Dickens, JC; Neuber, AA

PDF: https://pubmed.ncbi.nlm.nih.gov/28964249/

Abstract: A software controllable system which generates and transmits user defined RF signals is discussed. The system is implemented with multiple, modular transmitting channels that allow the user to easily replace parts such as amplifiers or antennas. Each channel is comprised of a data pattern generator (DPG), a digital to analog converter (DAC), a power amplifier, and a transmitting antenna. All channels are controlled through a host PC and synchronized through a master clock signal provided to each DAC by an external clock source. Signals to be transmitted are generated through the DPG control software on the PC or can be created by the user in a numerical computing environment. Three experiments are discussed using a two-and four-channel antenna array incorporating Chebyshev tapered TEM horn antennas. Transmitting distinct sets of nonperiodic bipolar impulses through each of the antennas in the array enabled synthesizing a sinusoidal signal of specific frequency in free space. Opposite to the standard phased array approach, each antenna radiates a distinctly different signal rather than the same signal simply phase shifted. The presented approach may be employed as a physical layer of encryption dependent on the position of the receiving antenna. Published by AIP Publishing.

Journal

Analysis Of Intensity Dependent Near-Bandedge Absorption In Semi-Insulating 4H-Sic For Photoconductive Switch Applications

Authors: Meyers, V; Chowdhury, AR; Mauch, D; Dickens, JC; Neuber, AA; Joshi, RP

PDF: https://iopscience.iop.org/article/10.1088/1361-6463/aa59aa/pdf

Abstract: We report on the intensity-dependent behavior of the absorption coefficient (alpha) in semiinsulating 4H-SiC material. Data from as-received samples show a monotonic decrease in a with incident energy density, with a pronounced change in slope at around 10 mJ cm(-2). Annealed samples, on the other hand, exhibit an experimental trend of increasing alpha with intensity. Qualitative explanation of the observed behavior is presented that probes the possible role of spontaneous and stimulated emission for as-received samples. With annealing, trap related recombination is strongly reduced leading to higher carrier densities and increased free-carrier absorption with incident intensity. The role of band-filling and permittivity changes are shown to be inconsequential, while changes in internal fields could contribute to decreases in absorption.

Journal

Current Handling Capability and Bond Degradation of Bond Wires under Pulsed Conditions

Authors: R. Rodriguez-Molina; D. Mauch; V. Meyers; A. Neuber; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=8496332

Abstract: Results detailing the current handling capability of Gold bond wires (1 mil diameter), and Aluminum ribbon (1mil x 10 mil) under pulsed conditions are presented. Gold wire bonds were formed through the ball-bonding technique, and the Aluminum wire was bonded through the wedge bonding technique. Both wires were bonded to gold plated bond pads. Varying peak current densities ranging from $2 \mathrm {x}10 ^{4}\mathrm {A}$ cm $^{-2}$ to $2 \mathrm {x}10 ^{7}\mathrm {A}$ cm $^{-2}$ were applied to bond wires at pulse-widths ranging from 50 ns to $500 \mu \mathrm {s}$. In addition, the effect of surrounding medium (SF6, HV epoxy, transformer oil) on the current capability was investigated. Failure modes observed were investigated with SEM imaging, and the evolution of these failure modes during current pulsing was captured with high-speeding imaging. Finally, the obtained results are compared with the experimental and theoretical results obtained from previous investigations conducted on exploding wires.

IEEE Conferences

Developing A High Power, Pulsed Uv Led System For Photoconductive Switching Applications

Authors: N. A. Wilson; D. L. Mauch; V. E. Meyers; J. C. Dickens; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=8496006

Abstract: Summary form only given. A very compact system integrating a high voltage pulser (up to 250 V) and high power UV LED (365 nm wavelength) was developed for triggering SiC photoconductive semiconductor switches (PCSS). The relationships between LED drive current and forward voltage to optical power were established for currents ranging from 0 A to 100 A at pulse widths ranging from 100 ns to 5 μs. The maximum optical power observed was 25 W. An optical system composed of a parabolic reflector and short focal length lenses was used to focus the emitted light onto a lateral geometry PCSS. The observed delivery efficiency was 63% onto a target 11 mm in diameter. Using the developed system, a SiC PCSS could be successfully triggered under high impedance load conditions.

IEEE Conferences

Electric Field Breakdown Versus Frequency Simulated Under Atmospheric Conditions For Large Gaps

Authors: H. K. Nguyen; A. Chowdhury; J. C. Dickens; R. P. Joshi; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=8496212

Abstract: Breakdown of air at atmospheric pressure in response to AC fields in gaps larger than 1 cm was simulated. Most previous literature concerning breakdown in this regime has focused on much smaller gaps1.

IEEE Conferences

Evaluation Of High Field And/Or Local Heating Based Material Degradation Of Nanoscale Metal Emitter Tips: A Molecular Dynamics Analysis

Authors: Zhang, Z; Giesselmann, M; Mankowski, J; Dickens, J; Neuber, A; Joshi, RP

PDF: https://scholars.ttu.edu/en/publications/evaluation-of-high-field-andor-local-heating-based-material-degra-14

Abstract: A molecular dynamics ( MD) model is used to study the potential for mass ejection from a metal nanoprotrusion, driven by high fields and temperature increases. Three- dimensional calculations of the electric fields surrounding the metal emitter are used to obtain the Maxwell stress on the metal. This surface loading is coupled into MD simulations. Our results show that mass ejection from the nanotip is possible and indicate that both larger aspect ratios and higher local temperatures will drive the instability. Hence it is predicted that in a nonuniform distribution of emitters, the longer and thinner sites will suffer the most damage, which is generally in keeping with the trends of a recent experimental report ( Parson et al 2014 IEEE Trans. Plasma Sci. 42 3982). A possible hypothesis for mass ejection in the absence of a distinct nanoprotrusion is also discussed.

Journal

Magnetic Field Diffusion Into Hollow Conductors With Walls On The Order Of The Skin Depth

Authors: Buntin, T; Collier, L; Dickens, J; Mankowski, J; Walter, J; Neuber, A

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8291285

Abstract: Transient magnetic diffusion through conductors of thickness comparable to the skin depth is investigated. Since an analytical solution is unavailable in this case, such magnetic diffusion results must be determined via simulation or experimentation. In the experimental approach, a sinusoidal current with peak values in the range of 20-30 kA (approx. 7 kHz ringing frequency) is passed through a two turn coil generating a sinusoidally varying magnetic field. A hollow structure with metallic walls of controlled thickness is placed roughly 10 cm away from the exciting coil. The focus of this investigation is on the transient skin depth, which occurs during the first half-wave of the signal, as that is most relevant for pulsed power applications. A calibrated B-dot probe placed inside the structure facilitates measurement of the diffused field. As expected, experimental data shows that magnetic field diffusion through the wall is not instantaneous, causing a delay before the diffused field is measured inside the test structure. The impact of cracks and holes in the conductor on the speed and magnitude of the magnetic field diffusion is elucidated. Results for materials of different conductivities are compared and analyzed for the transition between thin and medium walled cases. FEM simulations are validated alongside these experimental results and used to access a larger parameter space.

Conference Paper/Presentation

Model Predictions For Atmospheric Air Breakdown By Radio-Frequency Excitation In Large Gaps

Authors: Nguyen, HK; Mankowski, J; Dickens, JC; Neuber, AA; Joshi, RP

PDF: https://aip.scitation.org/doi/10.1063/1.4990699

Abstract: The behavior of the breakdown electric field versus frequency (DC to 100 MHz) for different gap lengths has been studied numerically at atmospheric pressure. Unlike previous reports, the focus here is on much larger gap lengths in the 1-5 cm range. A numerical analysis, with transport coefficients obtained from Monte Carlo calculations, is used to ascertain the electric field thresholds at which the growth and extinction of the electron population over time are balanced. Our analysis is indicative of a U-shaped frequency dependence, lower breakdown fields with increasing gap lengths, and trends qualitatively similar to the frequency-dependent field behavior for microgaps. The low frequency value of similar to 34 kV/cm for a 1 cm gap approaches the reported DC Paschen limit. Published by AIP Publishing.

Journal

Monte Carlo Analysis Of Field-Dependent Electron Avalanche Coefficients In Nitrogen At Atmospheric Pressure

Authors: Nguyen, HK; Mankowski, J; Dickens, JC; Neuber, AA; Joshi, RP

PDF: https://aip.scitation.org/doi/10.1063/1.5004995

Abstract: Calculations of electron impact ionization of nitrogen gas at atmospheric pressure are presented based on the kinetic Monte Carlo technique. The emphasis is on energy partitioning between primary and secondary electrons, and three different energy sharing schemes have been evaluated. The ionization behavior is based on Wannier's classical treatment. Our Monte Carlo results for the field-dependent drift velocities match the available experimental data. More interestingly, the field-dependent first Townsend coefficient predicted by the Monte Carlo calculations is shown to be in close agreement with reported data for E/N values ranging as high as 4000 Td, only when a random assignment of excess energies between the primary and secondary particles is used. Published by AIP Publishing.

Journal

Next Generation Ionospheric Heater Array

Authors: B. Esser; J. C. Dickens; J. J. Mankowski; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=8496347

Abstract: An electrically small antenna (ESA) is evaluated for its potential future use in a Transportable Ionospheric Heating (TIH) array. Consisting of a Small Loop Antenna (SLA) which inductively couples to a Capacitively Loaded Loop (CLL) the antenna provides a high-Q natural match to a $50 \Omega $ source. The capacitance of the CLL may be adjusted to tune the antenna in the range of ionospheric heating of approximately 3 – 10 MHz. Several methods are evaluated to achieve this tuning including a horizontal sliding plate design, and a hinged petal design.

IEEE Conferences

Nonlinear Uv Absorption Properties Of Bulk 4H-Sic

Authors: Meyers, V; Mauch, D; Dickens, J; Neuber, A

PDF: https://aip.scitation.org/doi/10.1063/1.4978768

Abstract: The intensity-dependent light absorption in bulk high-purity semi-insulating 4H-SiC at above band gap photon energies has been studied. In particular, 3.49 eV (355 nm) UV absorption of 160 lmthick samples of varying recombination lifetimes in the intensity range of 1 mJ/cm(2) -30 mJ/cm(2) is addressed. The effective absorption coefficient was found to vary up to 30% within this range. Assuming deep level trapping, interband absorption, and free carrier absorption as dominant processes, a four energy level model reproduces the experimentally observed absorption behavior. While nonlinearities in the optical absorption behavior of SiC have been studied previously as function of wavelength alpha(lambda), temperature alpha(T) and, to a very limited extent, at below bandgap optical intensities, the presented elucidates the UV intensity-dependent nonlinear absorption behavior, alpha(I), of SiC at above bandgap photon energies. Published by AIP Publishing.

Journal

Optical nonlinear absorption properties of 4h-SiC-experiment and model

Authors: V. Meyers; D. Mauch; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8291268

Abstract: Intensity-dependent nonlinear light absorption in bulk 4H-SiC at the above-bandgap energy of 3.49 eV (λ = 355 nm) is studied. Characterization and understanding of such nonlinear optical behavior in 4H-SiC forms the basis efficiency improvements and design of optoelectronic SiC devices, including photoconductive semiconductor switches. It is noted that previous research performed elsewhere had focused primarily on nonlinearities at below-bandgap energies, while little had been explored above-bandgap. In this study, absorption of short laser pulses with fluences ranging from 1 mJ/cm2 to 30 mJ/cm2 incident on 160 μm-thick high purity semiinsulating 4H-SiC samples of varying recombination lifetimes is addressed. Sample bulk recombination lifetimes vary from 0.5 ns to 100 ns displaying the range of effects from growth, electron irradiation, and annealing. The effective absorption coefficient varies significantly within this range as an apparent function of bulk recombination lifetime. A four-level time-and space-dependent finite difference time domain (FDTD) model taking into account electron trapping, interband absorption, and free-carrier absorption was constructed that yielded further insight into the absorption dynamics. For instance, the importance of free carrier absorption and deep-level trapping in the nonlinear absorption behavior is elucidated.

Conferences

Performance Analysis of an All Solid-State Linear Transformer Driver

Authors: L. Collier; J. Dickens; J. Mankowski; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7949116

Abstract: The performance of an all solid-state linear transformer driver (LTD) is evaluated based on experimentally verified behavior of a single stage. The single-stage LTD utilizes a low-profile design with robust thyristor switches and high-energy-density mica capacitors to minimize overall system inductance. Subnanosecond jitter is achieved with simultaneous thyristor triggering. The stage is magnetically coupled to a secondary winding through a central nanocrystalline core. A dc current source, decoupled with a large inductance, actively resets the core between pulses. The overall result is a low-impedance (<;1 Ω per stage) pulse generator that rivals the performance of traditional Marx systems with the improved reliability, increased lifetime, and fast rep-rate capabilities of solid-state switches. The stage is tested with charging voltages up to 8 kV into various loads and compared with simulations based on an analog behavioral thyristor switch model previously developed at Texas Tech University. The simulation is expanded into a full-scale, multistage LTD simulation and compared with a previously constructed Marx generator.

IEEE Journals

Pulsed Characterization Of A Uv Led For Pulsed Power Applications On A Silicon Carbide Photoconductive Semiconductor Switch

Authors: Wilson, N; Mauch, D; Meyers, V; Feathers, S; Dickens, J; Neuber, A

PDF: https://pubmed.ncbi.nlm.nih.gov/28863629/

Abstract: The electrical and optical characteristics of a high-power UV light emitting diode (LED) (365 nm wavelength) were evaluated under pulsed operating conditions at current amplitudes several orders of magnitude beyond the LED's manufacturer specifications. Geared towards triggering of photoconductive semiconductor switches (PCSSs) for pulsed power applications, measurements were made over varying pulse widths (25 ns-100 mu s), current (0 A-250 A), and repetition rates (single shot-5 MHz). The LED forward voltage was observed to increase linearly with increasing current (similar to 3.5 V-53 V) and decrease with increasing pulse widths. The peak optical power observed was >30 W, and a maximum system efficiency of 23% was achieved. The evaluated LED and auxiliary hardware were successfully used as the optical trigger source for a 4H-SiC PCSS. The lowest measured on-resistance of SiC was approximately 67 k Omega. Published by AIP Publishing.

Journal

Results Of A Compact Reflex Triode With Multi Cavity Adjustment

Authors: Barnett, DH; Rainwater, K; Dickens, JC; Neuber, AA; Mankowski, JJ

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8291276

Abstract: This study focuses on achieving wide tunability of a compact reflex triode virtual cathode oscillator (vircator). The cathode is of a bimodal carbon fiber (CF) material paired with a pyrolytic graphite anode. These materials display ideal operating characteristics which include but are not limited to, long lifetime > 10(6) shots, high operating temperatures > 1000 K, and large current densities similar to 200 A/cm(2). A 12 stage, 158 J pulse forming network (PFN) based Marx generator serves to drive the vircator at 350 kV, 4 kA with similar to 100 ns pulsewidth. The operating frequency of interest is in the range of 1-6 GHz, where tunability is achieved by varying the length of the anode-cathode (A-K) gap, the length from the back wall to the A-K gap, and/or the distance from the bottom of the cavity to the A-K gap. The primary focus in this research was to increase the achievable frequencies by placing a square waveguide within a sealed vacuum tube. This allows the bottom part of the waveguide to be easily adjusted while still maintaining the waveguide integrity. The resulting microwave frequencies are shown along with the system performance.

Conference Paper/Presentation

Synthetization Of Signals By The Transmission And Superposition Of Bipolar Impulses In Free Space

Authors: Z. Shaw; W. Feilner; J. C. Dickens; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=8496174

Abstract: A low power prototype antenna array with multi-channel transmission capabilities is incorporated to synthesize sinusoidal signals in free space from non-periodic source signals. Synthesis of a specified continuous signal is suitable in applications for spatially targeted plasma generation at high power. The system operates with an external 2.4 GHz clock source which allows for a 0.417 ns step resolution. Each antenna transmits an amplitude scaled set of non-periodic bipolar impulses $( \sim 2$ ns wide) which enables synthesizing an arbitrary signal at a specific point in free space only limited by the available number of antennas. A specific bipolar impulse set is found through the particle swarm optimization, PSO, technique with appropriate goal function selection. While the optimization is simply carried out in the time domain, the respective delay between antennas is matched in the experiment through electronic delays and/or physical antenna positioning.

IEEE Conferences

The Path to a Transportable Ionospheric Heater—Tuning Methods

Authors: B. Esser; S. R. Beeson; J. C. Dickens; J. J. Mankowski; T. M. Antonsen; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7929366

Abstract: A tunable electrically small antenna (ESA) designed to be naturally resonant at 100 MHz is evaluated for its range of tuning and feasibility for use in a mobile ionospheric heating (MIH) setup. The overarching goal is to match the ionospheric heating performance of the 180 element array at the high frequency active auroral research program (HAARP), which occupies approximately 1.2 × 105 m2 of land in Gakona, Alaska. While each HAARP crossed dipole element occupies 440 m2 of land and is tunable in the range of 2.7-10 MHz using automatic matching networks, the presented ESA approach is aimed toward enabling the fabrication of a transportable MIH array platform capable of high continuous wave (cw) power, albeit with a linear dimension five to ten times smaller than that of an equivalent dipole antenna. It is elucidated that the capacitively tuned ESA is continuously tunable to a frequency about 50% lower than that of the ESA's base frequency, albeit the resonant antenna structure carries a fractional bandwidth of merely 1%-2%.

IEEE Journals

Toward the development of an efficient bulk semi-insulating GaN photoconductive switch

Authors: Vincent Meyers; Daniel Mauch; Vladimir Kuryatkov; Sergey Nikishin; James Dickens; Andreas Neuber; Richard Ness

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8291269

Abstract: Photoconductive semiconductor switches (PCSS) made from bulk, semi-insulating GaN have been fabricated and tested under pulse-charged conditions. Switching response and photocurrent efficiency of GaN PCSSs triggered by sub-10 ns, 355 nm laser pulses is reported. It is shown that fast rise time (<;300 ns) voltage pulses can be used to charge a GaN PCSS to fields well beyond the DC breakdown field strength of GaN and improve switching performance. GaN's wide band gap, breakdown field strength, and electron mobility make it a material superior to SiC and far superior to GaAs for PCSS applications, though historically these materials have dominated PCSS research due to their relative ease of fabrication. Recent improvements to crystal quality and wafer size have allowed GaN and more recently semi-insulating GaN to play an increasing role in high-power and high-voltage solid state devices.

Conferences

2016

A 160 J, 100 Hz rep rate, compact Marx generator for driving and HPM source

Authors: K. Rainwater; D. Barnett; C. Lynn; J. Dickens; A. Neuber; J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8012819

Abstract: This paper presents the electrical and mechanical design considerations of a compact, 160 J modular pulse forming network (PFN) based Marx generator used to drive a high-power microwave (HPM) source with a time variant load at a PRF of 100 Hz. The modular Marx generator is designed to produce an open circuit output voltage of 600 kV from a 50 kV source using twelve stages. Each stage of the Marx was constructed from a PFN created with five, 2.1 nF, high voltage capacitors in parallel. Each Marx module was machined out of acetyl copolymer or Delrin to provide optimal strength, rigidity, and a dielectric constant that closely matches transformer oil. These Marx modules include air supply lines that are machined directly into each block of Delrin allowing airlines to connect to each module chamber rather than every spark gap. The spark gaps are comprised of two electrode inserts placed into the sealed pressure vessel contained within the Marx modules. The electrode inserts are of a sleeve-electrode design, which allows the user to insert the electrode into the sleeve, then the sleeve into the Marx module. The benefit of this design is the ability to adjust the electrode gap spacing without compromising the high pressure seal. Two continuous charging inductors run between each PFN and underneath the Marx modules. Due to high voltages generated by the Marx, outer field shaping rings are used to reduce the field stress across the induction coils, resulting in longer lifetime. The inductors are also of modular design allowing for individual coils to be replaced in the event of failure. Output voltage and current waveforms from a 60 Ohm water load are presented.

Conferences

A Take on Arbitrary Transient Electric Field Reconstruction Using Wavelet Decomposition Theory Coupled With Particle Swarm Optimization

Authors: K. Eldridge; A. Fierro; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7462994

Abstract: Destructive and constructive interference of multiple time-shifted and amplitude-adjusted higher frequency signals (wavelet signals) is exploited in order to reproduce a desired signal at a given point in the far-field regime of radiating antennas. The number of individual wavelets is intentionally kept small in keeping with a realistic antenna array size, where each antenna would emit wavelets at conceivably very high power levels. Wavelet decomposition theory is coupled with particle swarm optimization to determine the necessary time shifts and amplitude adjustments of the wavelet signals. In this application, the reconstructed signal can be specified by a desired frequency or arbitrary shape. A pyramidal horn antenna array is used in the analysis of the far-field propagation of the wavelet signals due to its relatively large bandwidth and known analytical electric field solutions. It is found that when the wavelet signals are appropriately superpositioned and added in the far field, the desired signal may be reconstructed with the quality of reconstruction mostly governed by the intentionally low number of wavelets. The reconstructed signal is solely found on the centerline while the signal drastically changes off the centerline or at distances too close or too far from the antenna array.

IEEE Journals

A Variable Resistance Thyristor-Type Switch Modeling Technique

Authors: M. B. Walls; A. Fierro; J. Dickens; J. Mankowski; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7543491

Abstract: An accurate model for simulating the transient turn-ON performance of thyristor-type switches is desirable for the development of solid-state pulse generators. The existing thyristor models are not suitable since they are either impractical to implement in an SPICE simulator, do not accurately model transient turn-ON performance, or are dependent on external circuit parameters that may not be known during the design phase, such as the load and discharge capacitance. An empirical model is developed and presented for Silicon Power's CCS SC 14N40 thyristor. The process of model determination is detailed, and waveforms obtained from the experiment and an SPICE circuit simulation that implements the thyristor model are discussed.

IEEE Journals

Assessing The Role Of Trap-To-Band Impact Ionization And Hole Transport On The Dark Currents Of 4H-Sic Photoconductive Switches Containing Deep Defects

Authors: Chowdhury, AR; Dickens, JC; Neuber, AA; Joshi, RP

PDF: https://aip.scitation.org/doi/10.1063/1.4972968

Abstract: Simulation studies of the electrical response characteristics of 4H-SiC switches containing traps are reported in the absence of photoexcitation. The focus is on trap-to-band impact ionization and the role of hole injection from the anode. Simulations show that hole-initiated ionization can be more important than the electron-initiated process. The results also underscore the role of hole injection at the high applied voltages. Our one-dimensional, time-dependent model yielded reasonable agreement with measured current-voltage data spanning over three orders of magnitude, but only when impact ionization was taken into account. Finally, the simulations predicted undulations in the device conduction current density with respect to time, due to the dynamic interplay between impact ionization, spatial electric field values, and occupancies of the trap levels. Published by AIP Publishing.

Journal

Breakdown characteristics of a silicon carbide photoconductive semiconductor switch triggered spark gap

Authors: Takeshi Ihara; Daniel Mauch; James Dickens; Andreas Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7534406

Abstract: Summary form only given. Development of a switch capable of operation at high voltages, high repetition frequency, with long lifetime is essential for furthering pulsed power applications. Photoconductive semiconductor switches (PCSSs) possess inherent optical isolation and extremely low switching jitter (~10 ps), and have also been experimentally shown to be capable of switching high voltages (up to 50 kV) and currents with very fast rise and fall times (<; 1 ns)[1-2]. In this paper, we report the breakdown characteristics of a SiC PCSS triggered spark gap obtained via measurement of the voltage and current, and simulation of the electric field distribution. The triggered spark gap is composed of sphere-to-sphere electrodes and a field distortion electrode, which is kept at mid-potential in the center plane between the two spherical main electrodes. A normally open PCSS is connected between one of the main electrodes and the mid-plane (trigger) electrode, whose center bore diameter is varied from 5 to 15 mm. With application of the optical pulse to the PCSS, the trigger electrode is temporarily connected to the main electrode, effectively doubling the electric field between the trigger and opposite electrode, leading to main gap closure. In essence, while bulk SiC PCSS switching currents demand very high optical power input, the synergy of bulk SiC PCSS and traditional spark gaps enables the triggering of large current flows at very modest optical powers with low jitter. Overall, the obtained results reveal that incident laser energy and mid-plane electrode geometry heavily influence the breakdown characteristics of the spark gap including jitter time, and breakdown voltage.

Conferences

Characteristics Of A Four Element Gyromagnetic Nonlinear Transmission Line Array High Power Microwave Source

Authors: Johnson, JM; Reale, DV; Krile, JT; Garcia, RS; Cravey, WH; Neuber, AA; Dickens, JC; Mankowski, JJ

PDF: https://aip.scitation.org/doi/10.1063/1.4947230

Abstract: In this paper, a solid-state four element array gyromagnetic nonlinear transmission line high power microwave system is presented as well as a detailed description of its subsystems and general output capabilities. This frequency agile S-band source is easily adjusted from 2-4 GHz by way of a DC driven biasing magnetic field and is capable of generating electric fields of 7.8 kV/m at 10 m correlating to 4.2 MW of RF power with pulse repetition frequencies up to 1 kHz. Beam steering of the array at angles of +/- 16.7 degrees is also demonstrated, and the associated general radiation pattern is detailed. Published by AIP Publishing.

Journal

Compact Reflex Triode With Multi Cavity Adjustment

Authors: Barnett, DH; Rainwater, K; Lynn, CF; Dickens, JC; Neuber, AA; Mankowski, JJ

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7534308

Abstract: This study focuses on the achieving wide tunabiltiy of a compact reflex triode virtual cathode oscillator (vircator). The cathode is of a bimodal carbon fiber (CF) material paired with a pyrolytic graphite anode. These materials where chosen for their operating characteristics which including but not limited to, long lifetime > 106 shots, high operating temperatures > 1000 K, and large current densities ~200 A/cm3 . A 12 stage, 158 J pulse forming network (PFN) based Marx generator serves to drive the Vircator at 350 kV, 4 kA with ~100 ns pulsewidth. The operating frequency of interest is in the range of 1-6 GHz, where the tunability is achieved by varying the size of the anode-cathode (A-K) gap, the length from the back wall to the A-K gap, or/and the distance from the bottom of the cavity to the A-K gap. The primary focus in this experiment was to increase the achievable frequencies by placing a square waveguide within a sealed vacuum tube. This allows the bottom part of the waveguide to be easily adjusted while still maintaining the waveguide integrity. The resulting microwave frequencies are shown along with the systems performance.

Conference Paper/Presentation

Contact Extensions Over a High- $k$ Dielectric Layer for Surface Field Mitigation in High Power 4H–SiC Photoconductive Switches

Authors: A. R. Chowdhury; D. Mauch; R. P. Joshi; A. A. Neuber; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7505601

Abstract: We focus on a simulation study to probe the mitigation of electric fields, especially at the edges of metal contacts to SiC-based photoconductive switches. Field reduction becomes germane given that field-induced failures near contacts have been reported. A dual strategy of extending metal contacts to effectively spread the electric field over a larger distance and to employ HfO2 as a high-k dielectric, is discussed. Simulation results show that peak electric fields can be lowered by up to ~67% relative to a standard design. Finally, our calculations predict that the internal temperature rise for a ~7-ns laser pulse and applied voltages around 20 kV (typical experimental values) would also be effectively controlled.

IEEE Journals

Discrete Photon Implementation For Plasma Simulations

Authors: Fierro, A; Stephens, J; Beeson, S; Dickens, J; Neuber, A

PDF: https://aip.scitation.org/doi/full/10.1063/1.4939475#:~:text=Here%2C%20a%20method%20applicable%20to%20plasma%20simulations%20is,of%20discretely%20tracking%20photons%20and%20their%20corresponding%20wavelengths.

Abstract: The self-produced light emission from pulsed plasma discharges and its impact on plasma development are challenging to characterize through simulation and modeling, chiefly due to the large number of radiating species and limited computer memory. Often, photo-processes, such as photoionization or photo-emission of electrons, are implemented through over-simplifying approximations or neglected altogether. Here, a method applicable to plasma simulations is implemented in a Particle-in-Cell/Monte Carlo Collision model, which is capable of discretely tracking photons and their corresponding wavelengths. Combined with the appropriate cross sections or quantum yields, a wavelength dependent model for photo-ionization or photo-emission may be implemented. Additionally, by resolving the wavelengths of each photon, an emission spectrum for a region of interest may be generated. Simulations for a pure nitrogen environment reveal that the calculated emission profile of the second positive system agrees well with the experimental spectrum of a pulsed, nanosecond discharge in the same spectral region. (C) 2016 AIP Publishing LLC.

Journal

Frequency tunability of a reflex-triode vircator using particle-in-cell modeling

Authors: P. M. Kelly; C. F. Lynn; J. M. Parson; J. Dickens; A. Neuber; J. J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7534045

Abstract: Summary form only given. The results from the development of a three-dimensional particle-in-cell (PIC) model investigating frequency tunability of a reflex-triode virtual cathode oscillator (vircator) are presented. These efforts have focused upon achieving stable frequency output at many different frequencies in the S, L, and C-bands, from a single tube, using the ICEPIC (Improved Concurrent Electromagnetic Particle-In-Cell) code from the Air Force Research Laboratory (AFRL). Experimental data from the hard-tube vircator at Texas Tech University (TTU), which operates at background pressures less than 10-9 Torr and utilizes a bimodal carbon fiber cathode and pyrolytic graphite anode, is used to validate simulation results. Additionally, the vircator at TTU is capable of changing the accelerating voltage, the anode-cathode (A-K) gap distance, and the distance of the cavity backwall relative to the position of the A-K gap on the fly without breaking tube vacuum, all in an effort to achieve greater frequency tunability and output power. However, this creates a very large, time-intensive experimental parameter space and makes a simulation model attractive for exploring additional output capabilities. ICEPIC results from a large combination of A-K gap distances, backwall distances, driving voltages, and cavity diameters are presented and compared to experimental results, highlighting frequency tunability of the system from a single tube.

IEEE Conferences

High Electric Field Atmospheric Breakdown Of Air At High Frequency For Large Gaps

Authors: A. R. Chowdhury; H. K. Nguyen; R. P. Joshi; J. C. Dickens; J. J. Mankowski; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7534285

Abstract: Summary form only given. Breakdown of air at atmospheric pressure in high frequency uniform electric fields and large gaps is discussed. In the high frequency band of a few MHz to few tens of MHz, the breakdown threshold voltage is lowered from its DC value due to enhanced space charge from ions that become trapped in the gap.1 While there is some literature concerning breakdown in this frequency range, it does not consider gaps larger than 1 cm.2A fluid model is developed to simulate plasma development in a baseline 6 cm gap primarily to explore power limitations for high power, electrically small antennas, which are operated cw at MHz frequencies. The ion densities are obtained from a drift-diffusion model, though data for the ionization, electron collision, and attachment parameters were obtained from Monte Carlo simulations, while ion diffusion and drift velocities were taken from the literature. As expected, the Monte Carlo simulations reveal that the EEDF follows any change in the electric field on the picosecond timescale at atmospheric pressures, much faster than any variation due to the externally applied electric field. Results from the simulation for gap lengths varying from the 6 cm baseline and air pressures are obtained, analyzed, and also compared with available reports.3

Conference Paper/Presentation

Investigation Of A Stripline Transmission Line Structure For Gyromagnetic Nonlinear Transmission Line High Power Microwave Sources

Authors: Reale, DV; Parson, JM; Neuber, AA; Dickens, JC; Mankowski, JJ

PDF: https://aip.scitation.org/doi/10.1063/1.4942246

Abstract: A stripline gyromagnetic nonlinear transmission line (NLTL) was constructed out of yttrium iron garnet ferrite and tested at charge voltages of 35 kV-55 kV with bias fields ranging from 10 kA/m to 20 kA/m. Typically, high power gyromagnetic NLTLs are constructed in a coaxial geometry. While this approach has many advantages, including a uniform transverse electromagnetic (TEM) mode, simple interconnection between components, and the ability to use oil or pressurized gas as an insulator, the coaxial implementation suffers from complexity of construction, especially when using a solid insulator. By moving to a simpler transmission line geometry, NLTLs can be constructed more easily and arrayed on a single substrate. This work represents a first step in exploring the suitability of various transmission line structures, such as microstrips and coplanar waveguides. The resulting high power microwave (HPM) source operates in ultra high frequency (UHF) band with an average bandwidth of 40.1% and peak rf power from 2 MW to 12.7 MW. (C) 2016 AIP Publishing LLC.

Journal

Limitations of bulk SiC photoconductive semiconductor switches, and evaluation of PIN SiC photoconductive semiconductor switches

Authors: D. L. Mauch; V. E. Meyers; R. P. Joshi; A. A. Neuber; J. C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7534404

Abstract: A comprehensive picture of the relationship between optical fluence, optical wavelength, system load, and photocurrent efficiency (PE) in SiC photoconductive semiconductor switches (PCSSs) is presented. Variation of the optical wavelength (300-380 nm) and optical fluence (0.2-200 J m-2) was accomplished with a Nd:YAG pumped optical parametric oscillator (7 ns FWHM) and a broadband variable attenuator. The PE was found to typically be in the range of 1-2 %, depending on wavelength, and the bulk PCSS on-state voltage driven by external circuit parameters. Features of the high electric field stress behavior (> 200 kV/cm) of the bulk PCSS were captured with high fidelity in a 1D drift-diffusion model with a self-consistent Poisson solver including trap assisted tunneling, Poole-Frenkel, and barrier lowering with enhanced tunneling effects. In addition, trap to band impact ionization as well as Coulombic and repulsive trapping potentials were included.

IEEE Conferences

Multichannel signal synthesis in free space

Authors: Z. Shaw; W. Feilner; C. Lynn; A. A. Neuber; J. C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=8012905

Abstract: A two antennae, software controllable phased array was designed and fabricated to study the generation and transmission of short, nanosecond, nonperiodic pulses. This system allows transmitting a train of appropriately scaled and time-shifted bipolar signals to generate received signals with major frequency components adjustable from approximately 600 MHz to 1.5 GHz. The main components in the system include two digital to analog converters (DACs), two data pattern generators (DPG), and two power amplifiers which drive two TEM Horn antennas. The horn antennas are based on a Chebyshev taper design and a Microstrip-type balun is utilized for the transition from the coaxial feed. This approach yielded a reasonably flat frequency response in a wide range from 0.2 to 3 GHz. Thus far, 100 ps synchronization between channels was achieved, and signals of varying shape and amplitude have been received via the shifting and inverting of Gaussian input pulses defined by the user generated data input vectors. This paper presents an experimental evaluation of the hardware used to generate the multichannel array, the ability to steer the signals and generate signals of varied frequency via superposition in free space.

IEEE Conferences

Next generation ionospheric heater antenna

Authors: B. Esser; J. Dickens; J. Mańkowski; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7534197

Abstract: An electrically small, three dimensional metamaterial inspired antenna at MHz frequencies is evaluated for its potential future use as the principle radiating element in a Mobile Ionospheric Heating (MIH) installation. The design consists of a small loop antenna (SLA) which inductively couples to a capacitively loaded loop (CLL) providing a high Q with a natural match to a 50 Ω source. At approximately 2.5 × 3 × 1.2 m in size the antenna is significantly smaller than the element, 21 × 21 × 16 m, used in the High-frequency Active Auroral Research Program (HAARP) array designed for ionospheric modification. With a gain upwards of 7 dBi when mounted above a sufficiently large ground plane, and up to 90 % efficiency, this electrically small antenna, ESA, provides a compact, efficient radiating element as a standalone radiator or as part of an array. It is demonstrated that tuning from approximately 3 to 10 MHz is possible via adjustment of the capacitance in the CLL and the mutual inductance between the SLA and CLL. A full-scale prototype antenna was fabricated and evaluated to obtain experimental radiation efficiencies and patterns at 500 W power levels, which compare favorably to simulations. Scaling for array operation revealed that it is conceivable to generate 3.6 GW ERP power in equatorial zones from a transportable platform based on the ESA. Such power levels suffice effecting ionospheric modification and, for instance, ELF wave generation in the range of 1-70 Hz.

IEEE Conferences

Numerical Assessment Of Secondary Electron Emission On The Performance Of Rising-Sun Magnetrons With Axial Output

Authors: A. Majzoobi; R. P. Joshi; A. A. Neuber; J. C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7570265

Abstract: Particle-in-cell simulations are performed to analyze the role of secondary electron emission (SEE) on the efficiency, the output power and the leakage currents of 12-cavity, 12-cathode Rising-Sun magnetrons with diffraction output. The simulation results seem to indicate that the role of SEE would be fairly negligible. Small changes are predicted, linked to deviations in the starting trajectories of secondary electrons following their generation and the lower fraction of electrons in clusters with a synchronized rotational velocity. Overall, a peak power output of about 2.48 GW is predicted at a magnetic field of 0.45 T, with efficiencies as high as 75%. Furthermore, deviations in the output power with SEE are predicted to occur at shorter times, but would not be an issue for pulses greater than 25 ns in duration.

Journal

Optical nonlinear absorption characterization of bulk semi-insulating 4H-SIC at and above the band edge

Authors: V. Meyers; D. Mauch; J. Mańkowski; J. Dickens; R. Joshi; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7534405

Abstract: Nonlinearity of optical absorption in semi-insulating bulk 4H-SiC has been investigated. Of interest was the optical bleaching behavior of 4H-SiC at and just above the band edge in the range 3.11-3.33 eV (wavelength 380-355 nm). Results of experiments on 200 μm and 490 μm thickness samples indicate partial bleaching in the optical fluence range from 70 W/cm2 to 1.8 kW/cm2, and the absorption coefficient was found to vary by approximately 10% within this range. These experimental findings are supported by simulation results obtained from a first order semi-empirical rate based model linking excitation-induced change in density of states with the absorption coefficient over the range of tested power densities. As expected, this effect scales with photon energy. Characterization of 4H-SiC absorption behavior under varying fluence will aid in design optimization of a Photoconductive Semiconductor Switch (PCSS).

IEEE Conferences

Particle-In-Cell Modeling Of A Reflex-Triode Vircator Using Icepic

Authors: P. M. Kelly; J. Dickens; A. Neuber; J. J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7534046

Abstract: This study describes a three-dimensional particle-in-cell (PIC) simulation for a reflex-triode virtual cathode oscillator (vircator). In particular, these efforts have focused upon the development of a robust, consistent model using the ICEPIC (Improved Concurrent Electromagnetic Particle-In-Cell) code from the Air Force Research Laboratory (AFRL). The vircator operates at background pressures less than 10-9 Torr and utilizes a bimodal carbon fiber cathode and pyrolytic graphite anode. Experimental data from the hard-tube vircator at Texas Tech University (TTU) is used to validate simulation results. A working, three-dimensional model of a reflex-triode vircator allows for better understanding of the physical processes responsible for microwave generation and thus enables the development of a more efficient and more customizable system. Simulation results detail the virtual cathode formation and the subsequent extraction of radiated microwave energy. Rather than relying on a non-directional isotropic radiation pattern for the radiated power, the true effective radiated power (ERP) from a three-dimensional, frequency-dependent radiation pattern has been extracted from the ICEPIC model. Furthermore, contributions from higher-order modes, particularly in the upper C-band regime, lead to frequency hopping and decreased microwave output power. Simulated results aid in identifying mode contributions and developing schemes to minimize contributions from undesirable modes. ICEPIC results are presented and compared against experimental results at several different operating conditions.

Conference Paper/Presentation

Pulsed characterization of a UV led for pulsed power applications

Authors: Nicholas A. Wilson; Daniel L. Mauch; James C. Dickens; Andreas A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7534040

Abstract: Summary form only given. The electrical and optical characteristics of a high power UV LED (365 nm wavelength) were evaluated under pulsed operating conditions for pulsed power applications. Measurements were made over varying pulse width (30 ns-100 μs), current (0 A-250 A), repetition rate (single shot -1 MHz), and temperature (23° C-80° C). Diagnostics used included a calibrated photodiode operating in the linear regime for transient optical power measurements, a grating / high speed ICCD based spectrograph for transient spectral analysis, and multiple 10:1 standard oscilloscope probes configured differentially for electrical measurements. A red shift was observed in the output spectrum of the LED with increasing temperature and increasing pulse-width. LED forward voltage was observed to increase linearly with increasing current (≈ 3.5 V-5.2 V) and decrease with increasing pulse-width. The peak optical power observed was > 13 W and a maximum efficiency of 22 % was observed. The evaluated LED and auxiliary hardware were successfully used as the optical trigger source for a SiC photoconductive semiconductor switch (PCSS) under high impedance conditions.

Conferences

Reflex Triode Vircator Design For Extended Frequency Tuning Capabilities

Authors: C. Lynn; D. Barnett; K. Rainwater; A. Neuber; J. Dickens; J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7534307

Abstract: A stand-alone vircator based high power microwave system has been designed as an effects test source. The goal of this system is to cover the frequencies from 4.0 GHz to 6.0 GHz. To date a working prototype has been manufactured and field tested. The current system is capable of producing microwaves at frequencies of 4.06, 4.27, 4.45, 5.83, 5.95 and 6.06 GHz at field levels in excess of 100 kV/m, measured at 3 meters. Additionally, the source and all subsystems are capable of burst mode operation for a duration of 2 s at 500 Hz pulse repetition frequency (PRF). The wide range of tunability was achieved by varying the A-K gap as well as the location of the A-K gap inside the cavity. The A-K gap is varied by a bellows sealed linear actuator which is attached to the cathode. The position of the A-K gap within the cavity is altered by moving a liner and microwave reflector (which form a cavity) within the main vacuum tube. However, the experimentally observed frequencies obtained with the current system leaves a gap from 4.45 to 5.6 GHz. In order for the test system to produce microwaves within this frequency range, a new tube is under development. The cavity of the new tube has a smaller cavity which should push the resonant frequencies into the desired range (from 4.45 GHz to 5.6 GHz). This presentation discusses the experimental results obtained with the new tube and compares that with the previously built and tested source.

Conference Paper/Presentation

The path to a transportable ionospheric heater

Authors: A. A. Neuber; D. L. Mauch; V. E. Meyers; B. Esser; R. P. Joshi; J. C. Dickens; J. J. Mankowski; T. M. Antonsen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7534401

Abstract: A transportable ionospheric heater, TIH, research design is presented that will enable plasma studies of the ionosphere in latitudes that are presently inaccessible by fixed installations such as HAARP (High Frequency Active Auroral Research Program). The equatorial latitude with close to zero vertical magnetic fields is especially of interest for basic plasma physics studies as well as rf communication enhancement. To achieve a power level in the ionosphere of at least 70 dBW ERP in a footprint significantly smaller than HAARP the radiated power needs to be substantially increased. This minimum ERP is achievable in a 4 × 4 antenna array with 370 kW input power per element with about 25 m by 25 m footprint vs. HAARP's equivalent 365 m by 365 m (360 antenna elements total, 10 kW maximum per antenna). Maximum ERP, up to 95 dBW, may be achieved with the TIH on a 115 m by 70 m platform, a factor 17 reduced size from HAARP. Tunable, Electrically Small Antennas, ESAs are employed to overcome the maximum power limitations of the HAARP dipole based antennas. This demands a step-up from 10 kW to several 100 kW cw power in the 3 to 10 MHz band, which is required to effectively heat the ionosphere. Driving the ESAs necessitates a tunable rf source in the same power and frequency regime, where a more traditional rf tube or all solid state approach may be pursued. The focus of the driver related research has been on photoconductive solid state switching, PCSS, in a direct drive mode that incorporates the driver into the antenna itself. A full size ESA operating at 9.5 to 10 MHz has been demonstrated at 500 W cw power levels and ~ 90% efficiency, driven by a single SiC switch mimicking the full power PCSS operation. The challenges and physics limitations of scaling the switch, the tunable ESA antenna design, as well as their coupling are presented. The significant progress made towards a transportable ionospheric heater as it relates to the physics of the PCSS switching efficiency, electrical breakdown in the MHz regime in large gaps, lower power experiments, and numerical simulations is discussed.

IEEE Conferences

Transient electromagnetic field reconstruction from sets of non-periodic oscillations

Authors: W. Feilner; Z. Shaw; C. Lynn; J. C. Dickens; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=8012903

Abstract: Arbitrary transient electric field shapes are generated in free space utilizing a set of transient signals with proper shape, amplitude, and time shift. Akin to wavelets in signal processing, brief, non-periodic oscillations are superimposed at a pre-selected location in space to effect destructive and constructive interference. With a properly chosen signal set, an entirely different frequency or shape is generated. Two methods have been employed to find optimum signal sets, the Discrete Wavelet Transform (DWT) and Particle Swarm Optimization (PSO). While the DWT approach dictates constant time step and rectangular matching between wavelets, PSO is not restricted in this manner, allowing for more flexibility in choosing amplitudes and signal delays.

IEEE Conferences

2015

1 kHz rep-rate operation of a spark-gap switched gyromagnetic nonlinear transmission line array

Authors: J. Johnson; D. Reale; D. Barnett; R. Garcia; W. Cravey; J. Parson; A. Neuber; J. Dickens; J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7296894

Abstract: This paper details the design, fabrication and performance of a coaxial ferrimagnetic nonlinear transmission line (NLTL), four element array, high power microwave (HPM) system operated at a 1 kHz repetition rate. Prime power is delivered from an 802L TDK Lambda power supply which charges a 5.2 nF capacitor bank up to -40 kV. The capacitors are discharged through a center pin trigatron spark gap. The trigger generator is optically isolated and battery powered for noise immunity and portability. It produces a 20 kV positive polarity pulse with a 20 ns risetime. The high dV/dt (1 kV/ns) is desirable to reduce jitter inherent to spark-gap switching. After the spark-gap switch has closed, the pulse is split four ways. The four pulses propagate through four adjustable delay lines for synchronization of the individual outputs. The four delay lines connect directly into four 76 cm NLTLs with NiZn ferrites where SF6 is the insulating dielectric. Each NLTL is terminated into a custom fabricated, Rexolite-filled, TEM horn antenna via a zipper balun. Lastly, a LabVIEW based control system automates the whole system using a National Instruments cRIO controller. Experimental observations will include in-line D-dot measurements of voltage waveforms and radiated D-dot field measurements.

IEEE Conferences

A 2D finite difference simulation to investigate the high voltage blocking characteristics of 4H-SiC photoconductive semiconductor switches

Authors: J. Shaver; D. Mauch; R. Joshi; J. Mankowski; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7296867

Abstract: 4H-SiC Photoconductive Semiconductor Switches (PCSSs) have shown significant promise for use in pulsed power related switch applications. This simulation uses the finite difference method, parallelized using a NVIDIA graphical processing unit and the CUDA framework, to solve the system of partial differential equations that model the semiconductor physics involved in the high voltage blocking state of the photoconductive switch. By taking into consideration material properties (mid-band gap trap energy level and concentration, etc.), we are able to gain an understanding of how changes in these parameters affect the space-charge-limited (SCL) currents observed in the high voltage blocking state. This subsequently allows for a fundamental understanding of the parameters controlling the high voltage switching capability of photoconductive switches. Results of the simulation are presented.

IEEE Conferences

A Frequency Stable Vacuum-Sealed Tube High-Power Microwave Vircator Operated at 500 Hz

Authors: Jonathan M. Parson; Curtis F. Lynn; Mike C. Scott; Steve E. Calico; James C. Dickens; Andreas A. Neuber; John J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7052371

Abstract: Operation of repetitive high-power microwave (HPM) sources is predominantly limited by thermal properties of anode and cathode materials. This letter presents a reflex-triode virtual cathode oscillator (vircator) capable of operating at 500 Hz at current densities between 100-200 A/cm2 for multiple burst durations of 1-2 s. Stable vircator operation under such a thermally punishing environment is facilitated by the use of a thin pyrolytic graphite anode. The results presented focus on two anode-cathode (A-K) gap spacings: 11 and 21 mm, which produce stable microwave radiation at 4.6 and 1.6 GHz, respectively. Characteristic voltage, current, and microwave waveforms in conjunction with short-time Fourier transforms, frequency spectrographs, and HPM power density data for 1000 and 500 pulses at 1.6 and 4.6 GHz, respectively, are presented.

Journals

A High Power Microwave Triggered Rf Opening Switch

Authors: Beeson, S; Dickens, J; Neuber, A

PDF: https://aip.scitation.org/doi/10.1063/1.4914043

Abstract: A 4-port S-band waveguide structure was designed and fabricated such that a signal of any amplitude (less than 1 MW) can be switched from a normally closed state, <0.5 dB insertion loss (IL), to an open state >30 dB IL by initiating plasma in a gas cell situated at the junction of this waveguide and one propagating a megawatt level magnetron pulse. The 90/10 switching time is as low as 20 ns with a delay of similar to 30 ns between the onset of the high power microwave pulse and the initial drop of the signal. Two ports of this device are for the high power triggering pulse while the other two ports are for the triggered signal in a Moreno-like coupler configuration. In order to maintain high isolation, these two sets of waveguides are rotated 90 degrees from each other with a TE111 resonator/plasma cell located at the intersection. This manuscript describes the design and optimization of this structure using COMSOL 4.4 at the design frequency of 2.85 GHz, comparison of simulated scattering parameters with measured cold tests (testing without plasma), and finally the temporal waveforms of this device being used to successfully switch a low power CW signal from 2W to <5 mW on a sub-microsecond timescale. (C) 2015 AIP Publishing LLC.

Journal

A Modular, High Rep-Rate, Fast-Risetime, Optically-Isolated, Pulse Trigger Generator

Authors: D. H. Barnett; J. M. Parson; C. F. Lynn; P. M. Kelly; J. C. Dickens; A. A. Neuber; J. J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7296790

Abstract: The paper presents the design and operational characteristics of an optically isolated, compact, modular pulse generator for spark-gap triggering applications. The pulse trigger generator is capable of operating at pulse repetition frequencies (PRFs) > 1 kHz for short bursts with variable pulse magnitudes and risetimes. The trigger generator utilizes a transformer, magnetic switch and an IGBT primary switch. It has been successfully used to trigger a trigatron-driven 10-stage, Marx generator driving a high power load. For portability and noise immunity, the trigger generator is optically isolated from its low voltage control and powered via a lithium ion polymer battery pack. A constant current dc-dc power supply charges the high voltage circuitry of the trigger generator and enables continuous operation with two modules. For operation, a large capacitor is initially charged and used as a buffer energy source. The intermediate charge storage in conjunction with a command-triggered MOSFET, provides the ability to quickly re-charge a trigger capacitor between each pulse of the burst. Circuit topology, experimental data, including voltage and current waveforms, and jitter of the overall system are discussed at various PRFs.

Conference Paper/Presentation

A wavelet approach to far-field signal reconstruction of transient electric fields

Authors: K. Eldridge-Looker; A. Fierro; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7296929

Abstract: Large antenna sizes present a severe limitation in the generation of low frequency signals. To alleviate this issue, a series of high frequency sources (and thus, smaller antenna sizes) may be combined to produce a lower frequency output in the far-field. This reconstruction technique applies to signals of arbitrary shapes in addition to frequency lowering. Due to the large parameter space, wavelet decomposition theory is coupled with particle swarm optimization to define appropriate time shifts and amplitude adjustments to the high frequency sources (wavelets) in order to synthesize an output signal with the desired frequency or shape. Fifteen individual high frequency wavelets (f = 1 GHz) are utilized in this application to produce a final output signal in the far-field of 600 MHz. The radiation of a single wavelet is simulated using a broadband Chebyshev TEM horn antenna in order to perform far-field constructive and destructive interference analysis of all 15 wavelet signals. Simulation of the TEM horn antenna shows reasonable wavelet signal fidelity with minimal reflections from the antenna aperture as the pulse is propagated to the far-field. Examination of the far-field electric field enables accurate temporal depiction of the reconstructed signal from the 15 pulsed sources at any given point in space. By adjusting the source array geometry, the location of the desired signal (determined by the particle swarm optimization) can be narrowed down to a single location. Overall, combining particle swarm optimization, wavelet decomposition theory, and electromagnetic wave propagation enables the accurate reconstruction of far-field temporal electric fields from the combination of 15 wavelet sources and verification of the desired signal location.

IEEE Conferences

Analysis Of A Tunable Electrically Small Antenna

Authors: Esser, B; Beeson, S; Dickens, J; Mankowski, J; Neuber, A

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7296897

Abstract: A tunable, metamaterial-inspired, electrically small antenna topology is evaluated for a possible future use as the principle radiating element in a mobile Ionospheric Heating (MIH) system. The RF source signal is fed via a 50 Omega coaxial cable into a small semi-loop antenna (SLA). This inductively couples to a capacitively loaded loop (CLL) providing a natural 50 Omega match to the source. The resonant frequency of the antenna can be adjusted by varying the capacitance of the CLL via inserting a large permittivity dielectric. A simplified circuit model is used to show that the resonant frequency can be tuned between 40 - 100 MHz. Also, the maximum power handling capabilities achievable with this antenna topology at frequencies relevant to ionospheric heating (similar to 10 MHz and below) are estimated.

Conference Paper/Presentation

Analysis Of High Field Effects On The Steady-State Current-Voltage Response Of Semi-Insulating 4H-Sic For Photoconductive Switch Applications

Authors: Tiskumara, R; Joshi, RP; Mauch, D; Dickens, JC; Neuber, AA

PDF: https://aip.scitation.org/doi/pdf/10.1063/1.4929809

Abstract: A model-based analysis of the steady-state, current-voltage response of semi-insulating 4H-SiC is carried out to probe the internal mechanisms, focusing on electric field driven effects. Relevant physical processes, such as multiple defects, repulsive potential barriers to electron trapping, band-to-trap impact ionization, and field-dependent detrapping, are comprehensively included. Results of our model match the available experimental data fairly well over orders of magnitude variation in the current density. A number of important parameters are also extracted in the process through comparisons with available data. Finally, based on our analysis, the possible presence of holes in the samples can be discounted up to applied fields as high as similar to 275 kV/cm. (C) 2015 AIP Publishing LLC.

Journal

Analysis of cathode emission phenomena: Effects of barrier thinning, field enhancements and local heating

Authors: A. Majzoobi; R. P. Joshi; A. Neuber; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7297005

Abstract: Intense electron emission from cathodes that provide very high current densities (several kA/cm2) is necessary for a various pulsed power applications. This contribution presents a quantitative analyses of the following processes and inherent physics: (a) Local field enhancements at micro-protrusions, (b) role of ion/ions near the emitting surface in lowering and thinning the potential barrier which increases emission. (c) localized heating at cathode tips that could produce hot-electrons and hot-phonons, ultimately leading to localized melting. Temperatures are predicted to possibly reach the cathode melting point on the nanosecond time scales. This is in keeping with the explosive emission phenomenon that is well known.

IEEE Conferences

Anode Materials for High-Average-Power Operation in Vacuum at Gigawatt Instantaneous Power Levels

Authors: Curtis F. Lynn; Jonathan M. Parson; Michael C. Scott; Steve E. Calico; James C. Dickens; Andreas A. Neuber; John J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7104123

Abstract: The thermal behavior of several electrically conducting solids under high incident electron fluence in high vacuum was evaluated. At electron energies of up to ~200 keV, the depth-dose relationship for electron penetration into the materials was considered, and the resulting energy deposition profile from the surface was revealed to extend to a maximum of ~175 μm below the surface depending on the anode material. Black body radiation is considered as the major mechanism that balances the power deposited in the material on the timescales of interest. Comparing the radiated power density at the sublimation temperature for different materials, metallic/nonmetallic, revealed that pyrolytic graphite anodes may radiate over 20 times more power than metallic anodes before failure due to sublimation. In addition, transparent pyrolytic graphite anodes (with a thickness on the order of several tens of micrometer) potentially radiate up to 40 times that of metallic anodes, since heating by the electron beam is approximately uniform throughout the thickness of the material, thus radiation is emitted from both sides. Experimental results obtained from titanium and pyrolytic graphite anodes validate the thermal analysis.

Journals

Burst mode operation of a high peak power high pulse repetition rate capacitor charging power supply

Authors: S. L. Holt; C. F. Lynn; J. M. Parson; J. C. Dickens; A. A. Neuber; J. J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7297029

Abstract: Fast capacitor charging is a power electronics application with unique challenges requiring both low voltage, high current operation and high voltage, low current operation from the same system at different points in the charge cycle. Such dynamically differing operating points create distinct challenges in obtaining high efficiency throughout a charge cycle. In addition, the power supply must be protected from negative voltage swings when attached to a high rep-rate power modulator. This paper presents the design and testing of a rapid capacitor charger designed for high rep-rate command charging of a Marx generator. The output stage uses a large inductor to delay discontinuous conduction during the early portion of the charge cycle and greatly improve efficiency. The design goals and tradeoffs will be discussed and simulation results will be compared to experimental data.

IEEE Conferences

Characterization Of The Optical Properties Of Gan:Fe For High Voltage Photoconductive Switch Applications

Authors: Meyers, V; Mauch, D; Mankowski, J; Dickens, J; Neuber, A

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7296862

Abstract: The optical properties of bulk semi-insulating GaN:Fe are obtained to assess its future suitability as a high voltage photoconductive semiconductor switch (PCSS). The material properties of GaN: Fe hold significant promise to improve devices for pulsed power and other applications. Growth techniques of bulk GaN: Fe, which have hitherto been largely insufficient for commercial applications, are nearing the point that anticipatory characterization research is warranted. In this paper, the optical constants of bulk GaN: Fe (refractive index, absorption coefficient, and off-state dielectric function) were determined by optical reflection/transmission analysis. The results of this analysis are compared with a similar treatment of bulk 4H-SiC as well as possible elements of PCSS housing: Sylgard 184 elastomer, and EFI 20003/50013 electrical potting epoxy. The data presented provide foundational material characterization to enable assessment of the feasibility of GaN: Fe as a practical high voltage PCSS material. Beyond basic materials research, these properties inform design optimization in PCSS construction and implementation.

Conference Paper/Presentation

Characterization of intra-bandgap defect states through leakage current analysis for optimization of 4H-SiC photoconductive switches

Authors: D. Thomas; D. Mauch; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7296950

Abstract: A method of characterizing mid-bandgap defect states in high purity semi-insulating 4H-SiC through leakage current analysis for optimization of SiC photoconductive switches is presented. The method utilizes two custom IV curve tracer systems to measure leakage currents through the material under various voltage/current conditions. The first system is used under low current conditions and is capable of measurements from 0 to 45 kV at currents ranging from 0 to 3 mA with pA resolution. A second system measures the transient discharge of a charged capacitor bank through the material. Due to power dissipation concerns, the second system is used for currents higher than 0.1 mA. Voltage/current measurements in this region (>0.1 mA) are of interest due to the information concerning defect states near the conduction band. These shallow defect states are detrimental to switching performance while offering little benefit to voltage hold-off. From the combined data of these two systems, characteristics of the defect states are extracted and presented. We further elucidate the effect of contact annealing temperature on shallow trap levels in electron-beam irradiated material (2*1018 1/cm2).

IEEE Conferences

Compact Reflex Triode Operation At 10 Hz Repetition Rate And Long Pulsewidths

Authors: Rocha, E; Parson, JM; Lynn, C; Dickens, JC; Neuber, A; Mankowski, J; Queller, T; Gleizer, JZ; Krasik, YE

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7179763

Abstract: This study focuses on the performance of a bimodal carbon fiber (CF) cathode and a carbon-epoxy multicapillary (CEM) cathode with microwaves at 50kV/m at 2m lasting 100 ns in a compact reflex triode virtual cathode oscillator (vircator). It was previously revealed that the CEM cathode was able to produce uniform emission distribution for a long duration1 . To further uncover the location(s) where plasma is forming, an intensified CCD camera is used to image both cathodes with high spatial and temporal resolution. A titanium grade 1 (TiG1) anode that is 70% transparent is used to minimize outgassing in the system resulting in the cathode being the primary outgassing constituent2 . One data set for each cathode was taken. Each data set contains diode current, voltage, and microwave fields over the course of 10,000 shots. A performance baseline is shown by comparing the evolution of these data over the course of the experiments. An 8 stage, 168 J pulse forming network (PFN) based Marx generator serves to drive both cathodes at 250 kV, 4 kA with ~175 ns pulsewidth, achieving current densities of ~200 A/cm3 . The operating frequency of interest is set in the range of 1-2 GHz, where the tunability is achieved by varying the size of the anode-cathode (A-K) gap. In all experiments the gap is fired at a 10 Hz pulse repetition rate. The characteristics of one type of cathode over the other, depending on the operating conditions, are discussed in detail.

Conference Paper/Presentation

Evaluating the Performance of a Carbon-Epoxy Capillary Cathode and Carbon Fiber Cathode in a Sealed-Tube Vircator Under UHV Conditions

Authors: Evan Rocha; Patrick M. Kelly; Jonathan M. Parson; Curtis F. Lynn; James C. Dickens; Andreas A. Neuber; John J. Mankowski; Tal Queller; Joseph Gleizer; Yakov E. Krasik.

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7163638

Abstract: This paper evaluates the performance of a bimodal carbon fiber cathode and a carbon-epoxy multicapillary cathode operating within a reflex-triode sealed-tube virtual cathode oscillator (vircator). The experimental results reveal that both cathodes exhibit similar emission behavior, although with some significant operational differences. An eight-stage 84-J pulseforming network-based Marx generator serves to drive both cathodes at 250 kV and 3-4 kA with a ~70-ns pulsewidth. Both cathodes undergo conditioning over 10000 pulses to determine gas evolution as well as electrical changes over time. Gas evolution of both cathodes is observed using a residual gas analyzer to determine individual gas constituents. A comparison of diode voltage, diode current, RF output, and outgassing data for both cathodes during vircator operation over 10000 pulses is presented to quantify cathode performance in a sealed-tube vircator. Changes in cathode surface morphology, from virgin to postmortem, are discussed. Data for various anode-cathode gap distances, from 3 to 15 mm, are presented. The evolution of voltage and current inputs to the vircator is discussed.

Journals

Evaluation of GaN:Fe as a high voltage photoconductive semiconductor switch for pulsed power applications

Authors: D. Mauch; J. Dickens; V. Kuryatkov; V. Meyers; R. Ness; S. Nikishin; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7296989

Abstract: Semi-insulating Gallium Nitride is evaluated as a candidate material for use as a high voltage photoconductive semiconductor switch (PCSS) for pulsed power applications. The GaN:Fe samples used for this investigation were commercially available, bulk, semi-insulating samples measuring 10 mm × 10 mm × 475 μm. Their optical and crystallographic properties were determined utilizing cathodoluminesence, photoluminescence, RHEED, as well as microwave reflection techniques for carrier lifetime studies. Experimental results are presented elucidating the potential of GaN:Fe sustaining high potential differences in both lateral and vertical geometry devices. For instance, electric field hold-off exceeding 100 kV/cm was observed in lateral geometry with mm sized gaps. In addition, a process for the homo-epitaxial growth of GaN:Si was developed in order to facilitate the fabrication of high quality ohmic contacts. Lastly, experimental results evaluating the on-state performance and photo-current efficiency of a GaN:Fe based PCSS are presented.

IEEE Conferences

Evaluation of a Pulsed Ultraviolet Light-Emitting Diode for Triggering Photoconductive Semiconductor Switches

Authors: D. Mauch; C. Hettler; W. W. Sullivan; A. A. Neuber; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7151899

Abstract: The power output, forward voltage, conversion efficiency, and spectral characteristics of a 365 nm ultraviolet light-emitting diode (LED) were measured for applications of triggering wide-bandgap photoconductive switches for pulsed power applications. Pulsed currents through the LED ranged from 125 mA up to 2.2 A at widths from 10 μs up to several seconds. Using time-resolved electroluminescence spectroscopy, peak emission was observed to occur at 368.5 nm for short pulses with a red-shift to 371.8 nm for pulses 8 s in duration. A peak light output of 4.1 W was measured for short pulses (<;50 μs) of 2.12 A, corresponding to six times the rated output specification. The LED was used to trigger a high-voltage photoconductive semiconductor switch (PCSS) at voltages up to 6 kV into a high-impedance load. The 365 nm LED is a promising candidate for optical triggering of PCSS devices.

IEEE Journals

Fundamental investigation of microsecond breakdown near a high permittivity dielectric

Authors: S. Feathers; A. Fierro; S. Beeson; J. Stephens; J. Dickens; A. Neuber; K. M. Williamson

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7799673

Abstract: A 3 microsecond risetime, 300 μs fall time, 25 kV high voltage pulse, chosen to emulate lightning discharges is used to investigate breakdown in close proximity to a high permittivity rutile dielectric (Er ~ 100) cylinder with 1 cm diameter. A needle-plane electrode structure is utilized with 1.05 cm electrode separation. The dielectric location is varied from immediately under the needle, to more than a 1 cm away from the needle axis. Basic system design and simulation are presented, along with simulations of the electric field distribution for various dielectric locations. The dependence of breakdown voltage on dielectric proximity is presented in detail. For instance, a minimum in breakdown voltage is observed when the dielectric cylinder is placed slightly off-center from the needle's center axis. Using high speed imaging, discharge inception and growth are presented with ~10 ns resolution.

IEEE Conferences

Gas selection and flow optimization for A 1 kHz trigatron spark gap

Authors: W. H. Cravey; D. V. Reale; R. S. Garcia; J. M. Johnson; A. A. Neuber; J. C. Dickens; J. J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7296987

Abstract: This paper discusses the design of a gas flow system for a 1 kHz repetition rate trigatron based spark gap. The system requires a flow rate high enough to clear the gas from the gap in under 1 ms while also maintaining the required operating pressure. The gap is a trigatron based design with an alumina insulated tungsten trigger pin. A 20 kV positive polarity pulse, with a 20 ns risetime, is applied to trigger the main gap which is charged to −40 kV. A brass guard ring is employed to shield the walls of the containment structure from contaminants in order to achieve a longer operational lifetime. Dry air and Nitrogen gasses are tested at various pressures and flow rates. Design considerations, such as inlet and outlet sizing and gap geometry, are taken into account to ensure a high air flow is achieved between the electrodes.

IEEE Conferences

High Power Lateral Silicon Carbide Photoconductive Semiconductor Switches and Investigation of Degradation Mechanisms

Authors: D. Mauch; W. Sullivan; A. Bullick; A. Neuber; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7108031

Abstract: Several generations of high power, lateral, linear mode, intrinsically triggered 4H-SiC photoconductive semiconductor switch designs and their performance are presented. These switches were fabricated from high purity semi-insulating 4H-SiC samples measuring 12.7 mm × 12.7 mm × 0.36 mm and were able to block dc electric fields up to 370 kV/cm with leakage currents less than 10 μA without failure. Switching voltages and current s up to 26 kV and 450 A were achieved with these devices and ON-state resistances of 2 Ω were achieved with 1 mJ of 355 nm laser energy (7 ns FWHM). After fewer than 100 high power switching cycles, these devices exhibited cracks near the metal/SiC interface. Experimental and simulation results investigating the root cause of this failure mechanism are also presented. These results strongly suggest that a transient spike in the magnitude of the electric field at the metal/SiC interface during both switch closing and opening is the dominant cause of the observed cracking.

IEEE Journals

Implementation of a battery management and protection system for high power pulsed applications

Authors: E. Cordero; S. Holt; J. Dickens; A. Neuber; J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7296920

Abstract: High power pulsed systems often require high current 3-phase electrical service or large generators to meet prime power requirements, limiting the portability of the systems. A high power battery system offers a useful alternative for mobile applications. Of all battery chemistries, Lithium-ion polymer (LiPo) has become popular in consumer electronics due to its high energy density, low self-discharge rate and lack of memory. Unfortunately, the chemistry still has limitations. Overcharging or overheating of a LiPo cell may result in ignition and over-discharge can destroy the cell. To prevent these hazards, overcharge and undercharge conditions must be monitored at the cell level rather than the battery level because the charge and discharge efficiency varies from cell to cell causing cell voltages within a battery to diverge during normal operation. A battery management system designed to monitor and maintain a large battery designed for pulsed power applications is presented in this poster. The design of this battery management system is presented and its implementation in a multi-cell, high voltage battery capable of high current pulsed operation. A hazard analysis of high power batteries and the implemented safety system is also provided.

IEEE Conferences

Initial testing of a reflex triode vircator with adjustable A-K gap and cavity reflector

Authors: C. F. Lynn; J. M. Parson; P. Kelly; D. H. Barnett; A. A. Neuber; J. C. Dickens; J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7296907

Abstract: Virtual cathode oscillators (vircators) can be easily tuned by altering the current density of the electron beam. This can be accomplished by changing the voltage applied to the a-k gap, or by physically changing the gap separation. Previous results with an adjustable a-k gap vircator achieved discrete tuning at frequencies of 1.5 GHz, 2.1 GHz, 4.1 GHz, 4.6 GHz, and 5.9 GHz. To achieve better tunability an adjustable cavity reflector was incorporated into the vircator design. Initial testing of the new vircator design has shown increased output power, as well as the ability to greatly increase the number of frequencies that can be tuned. Sweeping the A-K gap with the cavity reflector in two positions yielded 10 different frequencies of operation. Also sweeping the cavity reflector with the a-k gap set at 8.0mm yielded another unique frequency. Currently 11 unique frequencies have been identified, and the peak field measured from this vircator increased from ~40 kV/m to ~69 kV/m (> 70% increase in field). This paper illustrates the design of the vircator and presents some of the microwave data obtained. Additionally, a summary of all of the frequencies obtained and the peak field measured are included.

IEEE Conferences

Material Selection Of A Ferrimagnetic Loaded Coaxial Delay Line For Phasing Gyromagnetic Nonlinear Transmission Lines

Authors: Johnson, JM; Reale, DV; Cravey, WH; Garcia, RS; Barnett, DH; Neuber, AA; Dickens, JC; Mankowski, JJ

PDF: https://aip.scitation.org/doi/10.1063/1.4927719

Abstract: Implementing nonlinear transmission line (NLTL) technology in the design of a high power microwave source has the benefits of producing a comparatively small and lightweight solid-state system where the emission frequency is easily tuned. Usually, smaller in physical size, single NLTLs may produce significantly less power than its vacuum based counterparts. However, combining individual NLTL outputs electrically or in free-space is an attractive solution to achieve greater output power. This paper discusses a method for aligning a four element NLTL antenna array with coaxial geometry using easily adjustable temporal delay lines. These delay lines, sometimes referred to as pulse shock lines or pulse sharpening lines, are placed serially in front of the main NLTL line. The propagation velocity in each delay line is set by the voltage amplitude of an incident pulse as well as the magnetic field bias. Each is adjustable although for the system described in this paper, the voltage is held constant while the bias is changed through applying an external DC magnetic field of varying magnitude. Three different ferrimagnetic materials are placed in the temporal delay line to evaluate which yields the greatest range of electrical delay with the least amount of variability from consecutive shots. (C) 2015 AIP Publishing LLC.

Journal

Nanosecond, pulsed microdischarge UV and VUV sources

Authors: J. Stephens; D. Mauch; S. Feathers; J. Mankowski; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7179942

Abstract: Summary form only given. Using voltage pulses, 10s-100s of nanoseconds in length, microdischarges (MDs) are driven with up to 1 kV, and current levels from 30-150 A. Time-averaged input power levels from 10 W-1+ kW are achieved depending on the selection of pulse width and pulse repetition rate (1 kHz-1 MHz). Using an argon-hydrogen mixture, intense VUV radiation is generated at 121.6 nm (10.2 eV, Lyman-alpha). With this source, instantaneous power levels in excess of 60 watts have been achieved with several watts time-averaged power in the VUV. Additional work utilizing XeCl* (308 nm) and XeF* (351 nm) excimer sources is also reported. Achieved power levels, instantaneous and time-averaged, efficiency, and impurity content are reported. As an application, the MD-UV source is utilized as an alternative to a high power laser for the triggering of high voltage photoconductive SiC switches.

IEEE Conferences

Optically Isolated, 2 Khz Repetition Rate, 4 Kv Solid-State Pulse Trigger Generator

Authors: Barnett, DH; Parson, JM; Lynn, CF; Kelly, PM; Taylor, M; Calico, S; Scott, MC; Dickens, JC; Neuber, AA; Mankowski, JJ

PDF: https://aip.scitation.org/doi/pdf/10.1063/1.4913903

Abstract: This paper presents the design and operation characteristics of a solid-state high voltage pulse generator. Its primary utilization is aimed at triggering a gaseous spark gap with high repeatability. Specifically, the trigger generator is designed to achieve a risetime on the order of 0.1 kV/ns to trigger the first stage, trigatron spark gap of a 10-stage, 500 kV Marx generator. The major design components are comprised of a 60 W constant current DC-DC converter for high voltage charging, a single 4 kV thyristor, a step-up pulse transformer, and magnetic switch for pulse steepening. A risetime of <30 ns and pulse magnitude of 4 kV is achieved matching the simulated performance of the design. (C) 2015 AIP Publishing LLC.

Journal

Optimizing Drive Parameters Of A Nanosecond, Repetitively Pulsed Microdischarge High Power 121.6 Nm Source

Authors: Stephens, J; Fierro, A; Trienekens, D; Dickens, J; Neuber, A

PDF: https://iopscience.iop.org/article/10.1088/0963-0252/24/1/015013/pdf

Abstract: Utilizing nanosecond high voltage pulses to drive microdischarges (MDs) at repetition rates in the vicinity of 1 MHz previously enabled increased time-averaged power deposition, peak vacuum ultraviolet (VUV) power yield, as well as time-averaged VUV power yield. Here, various pulse widths (30-250 ns), and pulse repetition rates (100 kHz-5 MHz) are utilized, and the resulting VUV yield is reported. It was observed that the use of a 50 ns pulse width, at a repetition rate of 100 kHz, provided 62 W peak VUV power and 310 mW time-averaged VUV power, with a time-averaged VUV generation efficiency of similar to 1.1%. Optimization of the driving parameters resulted in 1-2 orders of magnitude increase in peak and time-averaged power when compared to low power, dc-driven MDs.

Journal

Particle-In-Cell Based Parameter Study Of 12-Cavity, 12-Cathode Rising-Sun Relativistic Magnetrons For Improved Performance

Authors: Majzoobi, A; Joshi, RP; Neuber, AA; Dickens, JC

PDF: https://aip.scitation.org/doi/full/10.1063/1.4932634

Abstract: Particle-in-cell simulations are performed to analyze the efficiency, output power and leakage currents in a 12-Cavity, 12-Cathode rising-sun magnetron with diffraction output (MDO). The central goal is to conduct a parameter study of a rising-sun magnetron that comprehensively incorporates performance enhancing features such as transparent cathodes, axial extraction, the use of endcaps, and cathode extensions. Our optimum results demonstrate peak output power of about 2.1 GW, with efficiencies of similar to 70% and low leakage currents at a magnetic field of 0.45 Tesla, a 400 kV bias with a single endcap, for a range of cathode extensions between 3 and 6 centimeters. (C) 2015 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution 3.0 Unported License.

Journal

Photoionization relevant extreme ultraviolet emission from developing low temperature plasmas in air

Authors: J. Stephens; A. Fierro; S. Beeson; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7179992

Abstract: HBSummary form only given. Using a self-matched transmission line pulse generator, high voltage pulses with magnitude 10-25 kV and ~25 ns pulse width are produced to excite low temperature plasma (LTP) formation. In using a short pulse, plasma formation is initiated, but the external excitation is removed before spark formation is completed, thus enabling a study of the LTP during its developmental phase. Using imaging in the visible spectrum and electrical diagnostics, this has been confirmed.To observe the 120 nm - 150 nm range, discharges are guided along the surface of an MgF2 observation window. On the opposing side of the window an evacuated spectrograph with intensified CCD enables the observation of VUV emission. Since the LTP is intentionally limited to its developmental phase, very low total light emission is becomes a diagnostic issue. Hence, it was necessary to accumulate light over several 10s of formation events before discrete lines in the spectra became evident. With a sufficient number of pulses, an experimental spectrum is generated in the 120+ nm range which was found to be in excellent agreement with theoretical atomic spectra of nitrogen and oxygen, with an assumed electron temperature of 1.6 eV. Using a gas puff system combined with an otherwise evacuated spectrograph enables the observation of extreme UV (EUV) to VUV light (80nm - 120 nm). In the photoionization relevant region of the spectra (below 103 nm), the observable emission consists of atomic neutral and singly ionized oxygen as well as molecular nitrogen. Data suggests that additional ground state transitions are present, but unobservable due to self-absorption and low overall light intensity. Most notably, the presence of photoionization capable emission in developing low temperature plasmas in air is verified.

IEEE Conferences

Plasma Etching Of N-Type 4H-Sic For Photoconductive Semiconductor Switch Applications

Authors: Ekinci, H; Kuryatkov, VV; Mauch, DL; Dickens, JC; Nikishin, SA

PDF: https://link.springer.com/content/pdf/10.1007/s11664-015-3658-z.pdf

Abstract: Photoconductive semiconductor switches (PCSS) fabricated on high-purity semi-insulating 4H-SiC substrates (000) are capable of switching high currents in compact packages with long device lifetimes. A heavily doped n-type SiC epitaxial layer of appropriate thickness is required to form low-resistance ohmic contacts with these devices. In addition, to enhance the performance of the PCSSs, the SiC surface between the ohmic contacts must be extremely smooth. We report a chlorine-based, inductively coupled plasma reactive ion-etching process yielding n-type SiC epitaxial layers with the required smoothness. The rate of etching and post-etching surface morphology were dependent on plasma conditions. We found that the surface smoothness of epitaxial layers can be improved by including BCl3 in the argon-chlorine mixture. The optimum etching process yielded very smooth surfaces (similar to 0.3 nm RMS) at a relatively high rate of etching of similar to 220 nm/min. This new fabrication approach significantly reduced the on-state resistance of the PCSS device and improved its durability of operation.

Journal

Repetitive Operation Of A Megawatt Class Reflex-Triode Vircator

Authors: J. M. Parson; C. F. Lynn; D. H. Barnett; S. L. Holt; P. M. Kelly; J. C. Dickens; A. A. Neuber; J. J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7296909

Abstract: Repetitive operation of high-power microwave (HPM) sources is primarily restricted by thermal properties of anode and cathode materials. Note that even in single shot operation, vircators generally inject undesired plasma from the anode/cathode surfaces under high current densities, leading to excessive heating of electrode materials, vacuum degradation and impedance collapse that may ultimately lead to cut-off of microwave power. Heating of the anode and cathode materials during repetitive operation intensifies these problems and will cause accelerated erosion and/or permanent damage of the anode and cathode surfaces, especially when metallic electrodes are used. Hence, the vircator herein utilizes a carbon fiber cathode and a pyrolytic graphite anode. This paper elucidates the heating of the anode and cathode, and their spectrally resolved black-body radiation properties during repetitive operation.

Conference Paper/Presentation

Self-Induced Gaseous Plasma As High Power Microwave Opening Switch Medium

Authors: Lin, S; Beeson, S; Liu, C; Dickens, J; Neuber, A

PDF: https://aip.scitation.org/doi/full/10.1063/1.4917471

Abstract: Self-induced gaseous plasma is evaluated as active opening switch medium for pulsed high power microwave radiation. The self-induced plasma switch is investigated for N-2 and Ar environments under pressure conditions ranging from 25 to 700Torr. A multi-pass TE111 resonator is used to significantly reduce the delay time inherently associated with plasma generation. The plasma forms under the pulsed excitation of a 4MW magnetron inside the central dielectric tube of the resonator, which isolates the inner atmospheric gas from the outer vacuum environment. The path from the power source to the load is designed such that the pulse passes through the plasma twice with a 35 ns delay between these two passes. In the first pass, initial plasma density is generated, while the second affects the transition to a highly reflective state with as much as 30 dB attenuation. Experimental data revealed that virtually zero delay time may be achieved for N-2 at 25 Torr. A two-dimensional fluid model was developed to study the plasma formation times for comparison with experimental data. The delay time predicted from this model agrees well with the experimental values in the lower pressure regime (error < 25%), however, due to filamentary plasma formation at higher pressures, simulated delay times may be underestimated by as much as 50%. (C) 2015 AIP Publishing LLC.

Journal

Solid state linear transformer driver (LTD) development for HPM sources

Authors: L. Collier; M. B. Walls; J. Dickens; J. Mankowski; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7296884

Abstract: The Marx pulse generator topology has been widely used in pulsed power applications1,2. Another pulse generator topology, the linear transformer driver (LTD), has been developed3 that may serve as a viable alternative to the Marx generator. LTDs utilize inductively added stages to achieve high voltages and currents. Unlike a Marx generator, each stage in an LTD features multiple bricks, all of which are ground referenced and allow current to be distributed amongst an arbitrary number of switches. This allows for LTDs that utilize solid-state switches, potentially resulting in more compact and reliable pulse generators. A solid-state, >10 kA peak current, multiple-stage LTD is developed. The generator's performance will be analyzed for viability as a replacement for driving a high power microwave generator.

IEEE Conferences

System integration of a coaxial ferrimagnetic nonlinear transmission line array

Authors: R. S. Garcia; D. V. Reale; J. M. Johnson; W. H. Cravey; A. A. Neuber; J. C. Dickens; J. J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7296893

Abstract: This paper describes the system integration of a four element, nonlinear transmission (NLTL) array. The HPM system components include a negative polarity 40 kV capacitor charging supply, a trigatron spark gap, a solid-state trigger generator, four delay lines with biasing coils, four coaxial ferrimagnetic NLTLs with biasing coils, eight dc current supplies, and four TEM horn antennas. A National Instruments cRIO FPGA based controller is used to interface the capacitor charging supply, the biasing coil power supplies and the trigger generator to a laptop based GUI. In order to minimize impact from EMI, all lines were properly shielded and the data acquisition equipment was located a sufficient distance away from the NLTL array. The GUI consists of options for controlling the current output on all 8 power supplies for biasing purposes, as well as pulse options that include repetitive pulsing based on the number of pulses or for a specific length of time. Pulse duration for the capacitor charger, the command charge, and the trigger can also be adjusted. An emergency stop button is included for safe shutdown of the trigger generator and all power supplies. A diagnostics setup is outlined describing the placement of inline coaxial D-Dot probes and a high voltage probe for laboratory testing.

IEEE Conferences

2014

10 kV, 44 ns pulse generator for 1 kHz trigatron reprate operation of NLTL

Authors: J. M. Johnson; J. M. Parson; D. V. Reale; A. A. Neuber; J. J. Mankowski; J. C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7287219

Abstract: This paper presents a design and implementation of a 1 kHz, 10 kV, positively pulsed trigger generator with an average risetime of 44 ns for use in a coaxial ferrimagnetic Nonlinear Transmission Line (NLTL) High Power Microwave (HPM) system. The pulse trigger generator is based on two stacked 4 kV current-controlled n-type thyristors in a low inductance package capable of driving inductive loads with risetimes less than 200 ns. However, by implementing a magnetic switch this relatively is slow risetime is sharpened to tens of nanoseconds. The stacked boards allow for voltage addition at the output while maintaining the fast riestime.

IEEE Conferences

3-D Simulation of Low-Temperature Plasma Development Under Pulsed Conditions

Authors: Andrew S. Fierro; James C. Dickens; Andreas A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6779603

Abstract: The development of a low-temperature plasma in a needle-protrusion to plane gap is investigated utilizing a 3-D particle-in-cell/Monte Carlo collision method implemented to run on single NVIDIA graphics processing unit. In addition to electron collisions, the model includes field detachment, photon tracking, and a drift-diffusion approximation for positive ions. The simulated geometry tracks several million electrons with 15-μm spatial resolution.

Journals

A Modular High Power Battery System For Pulsed Power Applications

Authors: E. Cordero; S. Holt; J. Dickens; A. Neuber; J. Mankowski; S. Calico; M. Scott

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7287370

Abstract: This paper presents the design of a scalable, high power battery system for pulsed power operations. The battery system is modular in design, with each module containing four Lithium Ion Polymer (LiPo) cells and a custom designed cell management board that actively monitors the voltage and temperature of each cell and also provides cell balancing functionality. The system is designed to be scalable by adding up to 25 modules in a series configuration. While the battery management system should be compatible with any lithium ion cells, this implementation uses 8 Ah capacity dual-core LiPo cells, rated for a 150 C discharge rate; allowing for a peak current output of 1,200 A. With 25 modules (96 LiPo cells) the system would have an open circuit voltage of 385 V and be capable of providing up to 1,200 A at 355 V for a peak output power of 420 kW. Special attention has been placed on safety features including overvoltage, undervoltage and temperature monitoring of every cell in the system. The charging/balancing system is capable of automatically shutting down if any of the voltages or temperatures exceeds established limits. The management circuitry is designed to have a low off-state power draw in order to maximize battery life when the system is not in use.

Conference Paper/Presentation

A Passive Measurement Of Dissociated Atom Densities In Atmospheric Pressure Air Discharge Plasmas Using Vacuum Ultraviolet Self-Absorption Spectroscopy

Authors: Laity, G; Fierro, A; Dickens, J; Frank, K; Neuber, A

PDF: https://aip.scitation.org/doi/pdf/10.1063/1.4869895

Abstract: We demonstrate a method for determining the dissociation degree of atmospheric pressure air discharges by measuring the self-absorption characteristics of vacuum ultraviolet radiation from O and N atoms in the plasma. The atom densities are determined by modeling the amount of radiation trapping present in the discharge, without the use of typical optical absorption diagnostic techniques which require external sources of probing radiation into the experiment. For an 8.0 mm spark discharge between needle electrodes at atmospheric pressure, typical peak O atom densities of 8.5 x 10(17) cm(-3) and peak N atom densities of 9.9 x 10(17) cm(-3) are observed within the first similar to 1.0 mm of plasma near the anode tip by analyzing the OI and NI transitions in the 130.0-132.0 nm band of the vacuum ultraviolet spectrum. (C) 2014 AIP Publishing LLC.

Journal

A Wavelet Approach To High Power Microwaves

Authors: Eldridge, K; Fierro, A; Dickens, J; Neuber, A

PDF: https://ieeexplore.ieee.org/document/7287262

Abstract: Wavelet decomposition and reconstruction are utilized to synthesize a high power microwave (HPM) signal at a frequency below the frequency of the employed radiating sources. Employing a larger number (on the order of ten) of smaller sources that produce short radiating pulses combined with appropriate amplitude scaling and shifting of the individual pulses enables the generation of a single waveform of longer duration. We describe the mathematical approach to the wavelet synthesis and give examples. For instance, an array of 10 sources, each producing a 0.5 ns pulse can be adjusted to generate a sinusoidal wave with a period of approximately 2 ns. The results of low power experiments are discussed in detail to demonstrate the practical feasibility of the wavelet approach.

Conference Paper/Presentation

A battery powered 80 kVA capacitor charger

Authors: S. Holt; E. Cordero; J. Mankowski; J. Dickens; A. Neuber; M. Scott; S. Calico

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7287211

Abstract: The design of a battery powered, rapid capacitor charger is discussed. The charger design is capable of an average output power of 80 kVA, for a burst time of roughly 5 seconds. Cool down time is required between bursts. A Lithium Ion Polymer (LiPo) battery pack with a nominal voltage of 355 V and fully charged open circuit DC voltage of 385 V will be used to power the rapid capacitor charger. The general topology of the charger is as follows. An IGBT H-bridge inverter uses pulse width modulation to create an AC waveform that is stepped up to a maximum of 58kV by a 1:170 ratio transformer. This high voltage output of the transformer is rectified and used to charge the capacitor bank.

IEEE Conferences

A metamaterial-inspired electrically small antenna for operation at 2 to 20 MHz

Authors: P. Gatewood; A. Neuber; J. Dickens; J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7287248

Abstract: A metamaterial-inspired, efficient, electrically small antenna (ESA) is designed for the 2 to 20 MHz range, intended for use in a mobile Ionospheric Heating (MIH) system. The ESA consists of two main parts: a small semiloop antenna (SLA), and an outer capacitively loaded loop (CLL). To increase the capacitance of the CLL and reduce the size of the ESA, a high permittivity dielectric is utilized. All designs were simulated in Ansoft HFSS with particular attention on radiation efficiency and bandwidth. The design aims for these ESAs are a high overall efficiency at dimensions much smaller than a wavelength.

IEEE Conferences

A wavelet approach to high power microwaves

Authors: Kaili Eldridge; Andrew Fierro; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7287262

Abstract: Wavelet decomposition and reconstruction are utilized to synthesize a high power microwave (HPM) signal at a frequency below the frequency of the employed radiating sources. Employing a larger number (on the order of ten) of smaller sources that produce short radiating pulses combined with appropriate amplitude scaling and shifting of the individual pulses enables the generation of a single waveform of longer duration. We describe the mathematical approach to the wavelet synthesis and give examples. For instance, an array of 10 sources, each producing a 0.5 ns pulse can be adjusted to generate a sinusoidal wave with a period of approximately 2 ns. The results of low power experiments are discussed in detail to demonstrate the practical feasibility of the wavelet approach.

Conferences

Bias-Field Controlled Phasing And Power Combination Of Gyromagnetic Nonlinear Transmission Lines

Authors: Reale, DV; Bragg, JWB; Gonsalves, NR; Johnson, JM; Neuber, AA; Dickens, JC; Mankowski, JJ

PDF: https://aip.scitation.org/doi/pdf/10.1063/1.4878339

Abstract: Gyromagnetic Nonlinear Transmission Lines (NLTLs) generate microwaves through the damped gyromagnetic precession of the magnetic moments in ferrimagnetic material, and are thus utilized as compact, solid-state, frequency agile, high power microwave (HPM) sources. The output frequency of a NLTL can be adjusted by control of the externally applied bias field and incident voltage pulse without physical alteration to the structure of the device. This property provides a frequency tuning capability not seen in many conventional e-beam based HPM sources. The NLTLs developed and tested are mesoband sources capable of generating MW power levels in the L, S, and C bands of the microwave spectrum. For an individual NLTL the output power at a given frequency is determined by several factors including the intrinsic properties of the ferrimagnetic material and the transmission line structure. Hence, if higher power levels are to be achieved, it is necessary to combine the outputs of multiple NLTLs. This can be accomplished in free space using antennas or in a transmission line via a power combiner. Using a bias-field controlled delay, a transient, high voltage, coaxial, three port, power combiner was designed and tested. Experimental results are compared with the results of a transient COMSOL simulation to evaluate combiner performance. (C) 2014 AIP Publishing LLC.

Journal

Carrier lifetime measurement of silicon carbide for photoconductive switch applications using an IR probe laser

Authors: C. White; D. Mauch; D. Thomas; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7287328

Abstract: A system for measuring the recombination lifetime of high purity, semi-insulating (HPSI) 4H-SiC through transient free carrier absorption (FCA) for optimization of SiC photoconductive semiconductor switches (PCSS) is presented. The system measures the transient absorption of a continuous, low-power (<;5mW) 1550 nm infrared probe laser. Free carriers were generated with both above and below bandgap illumination from the harmonics of a Nd: YAG laser (532 nm, 355 nm, and 266 nm-10ns FWHM), and the carrier lifetime was numerically calculated from the absorption transient. High spatial resolution (~10 um) was attained through the use of a high-precision, three-axis stage. The carrier lifetime measurements of various regions of several SiC PCSSs over varying levels of photo-excitation are presented.

IEEE Conferences

Characterization Of Mid-Bandgap Defect States In 4H-Sic For Optimization Of Sic Photoconductive Semiconductor Switches

Authors: Thomas, D; Mauch, D; White, C; Neuber, A; Dickens, J

PDF: https://ieeexplore.ieee.org/document/7287329

Abstract: A method of characterizing mid-bandgap defect states in high purity semi-insulating 4H-SiC through leakage current analysis for optimization of SiC photoconductive semiconductor switches, PCSS, is presented. The method utilizes two custom IV curve tracer systems to measure leakage currents through the material under various voltage/current conditions. The first system is used under low current conditions and is capable of measurements from 0 to 45 kV at currents ranging from 0 to 3 mA with pA resolution. While voltage/current measurements in the region >0.1 mA are of primary interest for quantifying defect states near the conduction band, standard IV measurements become difficult due to excessive power dissipation in the PCSS. Hence, a second system operating in transient mode is used for currents higher than 0.1 mA. This system measures the transient discharge of a charged capacitor through the PCSS, allowing for high current measurements while subjecting the material to high power dissipation for only a short period of time (milliseconds). It is the goal to extract from the combined data of these two systems characteristics of the defect states (concentration, energy level).

Conference Paper/Presentation

Conditioning of Carbon Fiber Cathodes in UHV-Sealed Tubes at 200 A/cm2

Authors: J. M. Parson; C. F. Lynn; J. J. Mankowski; M. Kristiansen; A. A. Neuber; J. C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6847740

Abstract: This paper presents a study on outgassing and electrical conditioning for three carbon fiber cathode types in a vacuum-sealed, high-power microwave virtual-cathode-oscillator (vircator) that operates in the low 10-9 torr pressure regime. The three cathode types consist of a bare bimodal fiber structure, a bare unimodal fiber structure, and a cesium-iodide coated bimodal fiber structure with identical fiber coverage of 2% by area with a surface area of ~20 cm2. The electrodes are cleaned by a 1.2 kW, argon/oxygen microwave plasma prior to complete vircator assembly, followed by a 300 °C bake-out for 72 h. Each cathode was pulsed in a single pulse operation by an 80 J, low inductance Marx generator with an approximate pulsewidth of 100 ns full-width at half-maximum for 10000 current pulses. The data presented includes individual gas constituents, high-speed intensified charge coupled device (ICCD) imaging, and voltage and current waveforms. The conditioning process resulted in a gas load reduction of ~80% overall, with the indication that the bare bimodal fiber structure performed the best as diode power increased throughout the experiment, while the power decreased for the other tested cathode types.

IEEE Journals

Design And Operation Of A Fast-Risetime, 500 Hz, 24 Kv, Optically-Isolated Pulse Trigger Generator

Authors: D. H. Barnett; J. Parson; C. Lynn; P. Kelly; M. Taylor; J. Dickens; A. Neuber; J. Mankowski; S. Calico; M. Scott

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7287287

Abstract: This paper presents the design and performance characteristics of an optically isolated, trigger generator for spark gap applications that is capable of operating at over 500 Hz rep rate. The pulsed trigger generator is designed to achieve fast risetimes on the order of 1kV/ns to cause breakdown between the trigatron trigger pin and the opposite electrode. The pulsed trigger generator is designed to trigger a 10-stage, 500 kV, 42 J Marx generator. The system is capable of delivering a 4"“25 kV pulse with a 10/90 risetime of 20 ns. A board was fabricated to control a capacitor charger and high voltage thyristor via fiber optic inputs. The capacitor charger, a 60 W constant current dc-dc power supply with variable voltage control, is capable of charging 1 nF in less than 0.3 ms. The system is battery-powered using a 33 V lithium polymer battery pack for isolated operation in noisy environments. For burst mode operation, a larger 250 nF buffer capacitor, which is initially charged, is connected through a 100 kΩ resistor to the trigger capacitor, which is varied between 1 and 40 nF. The value of the trigger capacitor is adjusted to provide optimum performance for a given transformer and magnetic switch. System modeling results along with experimental data are discussed including the reliability and performance of the overall system including jitter at 500 Hz operation.

Conference Paper/Presentation

Effect Of Bcl3 In Chlorine-Based Plasma On Etching 4H-Sic For Photoconductive Semiconductor Switch Applications

Authors: Ekinci, H; Kuryatkov, VV; Mauch, DL; Dickens, JC; Nikishin, SA

PDF: https://avs.scitation.org/doi/10.1116/1.4892172

Abstract: Inductively coupled plasma reactive ion etching (ICP-RIE) of n-type SiC epitaxial layers grown on (000 (1) over bar) 4H-SiC semi-insulating substrates has been investigated using chlorine-based plasma. The etch rate and postetching- surface morphology have been studied as functions of the plasma composition, ICP power, RTE power, and process pressure. The authors found that the surface smoothness of the epitaxial layer was increased by introducing BCl3 into Cl-2/Ar plasma. An optimized process has been developed yielding etch rates of similar to 220 nm/min and very smooth surfaces with root mean square roughness of similar to 0.3 nm. The spatial-frequency dependence of the one dimensional power spectral density was interpreted using the surface height function h(x) including a low-frequency range, which exhibits saturation and a high-frequency range, Which exhibits scaling properties. Through this etching process, the effects of s-ubcontact doping on 4H-SiC photoconductive semiconductor switch (PCSS) performance were investigated. A PCSS was fabricated using this etching process with a 1 mu m heavily doped (1.6 x 10(18) cm(-3) n-type) epitaxial layer beneath the device contacts and compared with a PCSS fabricated with a subcontact doped layer created through laser enhanced diffusion (similar to 50 nm depth, 2.0 x 10(18) cm(-3) n-type). The PCSS with the epitaxial layer demonstrated on average a 30% reduction in minimum on-state resistance, and eliminated cracking of the bulk material when switching currents <= 38 A. (C) 2014 American Vacuum Society.

Journal

Emission Behavior of Three Conditioned Carbon Fiber Cathode Types in UHV-Sealed Tubes at 200 A/ $\mathrm{cm}^{2}$

Authors: J. M. Parson; C. F. Lynn; J. J. Mankowski; A. A. Neuber; J. C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6945869

Abstract: When subjected to high electric fields in vacuum, carbon fiber cathodes produce intense electron beams suitable for high-power microwave (HPM) generation at very high current densities. However, the production mechanisms of these intense electron beams are not fully understood. This paper presents the postmortem examination of three conditioned carbon fiber cathode types. The three cathode types consist of an uncoated, bare unimodal fiber structure, a bare bimodal fiber structure, and a cesium-iodide (CsI)-coated bimodal fiber structure, all with identical fiber coverage of 2% by area. Each cathode was conditioned prior to testing by single pulse operation driven by an 80 J Marx generator for 10 000 pulses. HPM, voltage, and current waveforms of each cathode are presented. The bare bimodal cathode radiated more microwave power than the CsI-coated cathode and bare unimodal cathode. Scanning electron microscopy imagery presents evidence of two emission mechanisms: 1) explosive electron emission and 2) surface flashover, which both were found on the CsI-coated cathode. In addition, no evidence of surface flashover was found on either uncoated cathode.

IEEE Journals

Frequency tuning a reflex triode vircator from 1.5 to 5.9 GHz

Authors: C. F. Lynn; J. Parson; P. Kelly; M. Taylor; D. Barnett; A. Neuber; J. Dickens; J. Mankowski; S. Calico; M. Scott

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7287245

Abstract: Vircators (virtual cathode oscillators) are easily frequency tunable by simply altering the electron beam current density through either adjusting the accelerating voltage or varying the anode cathode gap (A-K gap). It is noted that vircators typically exhibit frequency hopping, an often undesired feature. Here we address the frequency hopping problem by introducing a rectangular shaped carbon fiber cathode with the width of the cathode less than one quarter of a wavelength in the direction of microwave propagation. Operating the vircator with the rectangular cathode revealed a match with a resonant condition from back wall reflections, which explains the observed dominant microwave frequency selection. That is, the vircator emitted stably during 50 ns operation at 3.89 GHz or 2.07 GHz with a 3 dB bandwidth of 37.5 MHz or 93.7 MHz, at A-K gap spacing of 8 mm, and 12 mm respectively. To further investigate frequency tuning, the A-K gap was swept from 3 mm to 17 mm while keeping a constant 5.1 cm diameter circular cathode. The resulting frequencies of operation were 1.5 GHz, 2.1 GHz, 4.1 GHz, 4.6 GHz, and 5.9 GHz at A-K gap spacing of 17mm, 14 mm, 7 mm, 5.75 mm, and 3 mm respectively. This demonstrates that a tuning range of 4.4 GHz should be achievable for a practical vircator system.

IEEE Conferences

Global Model for Total Delay Time Distribution of High-Power Microwave Surface Flashover

Authors: Sterling R. Beeson; James C. Dickens; Andreas A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6923463

Abstract: A global model of high-power microwave (HPM) window breakdown is elucidated. The model provides a practical approach for estimating the maximum microwave power and pulse length that can be transmitted for a given window geometry at varying background gas pressure. Based on recent experimental and modeling progress, the formative and statistical breakdown delay time contributions are included in the model. The provided details are intended to give the reader a starting point in designing an HPM system for which surface breakdown along the output window is a major concern. Spanning five orders of magnitude in power, four microwave bands, three orders of magnitude in pulsewidth, three orders of magnitude in pressure, and three different gas types, the model serves to determine the probability of breakdown for a given set of input parameters with the modest computational effort. Examples of how to use the model are given, and the results are compared with actual systems and measured experimental delay times.

Journals

Graphics Processing Unit Accelerated Three-Dimensional Model For The Simulation Of Pulsed Low-Temperature Plasmas

Authors: Fierro, A; Dickens, J; Neuber, A

PDF: https://aip.scitation.org/doi/10.1063/1.4903330

Abstract: A 3-dimensional particle-in-cell/Monte Carlo collision simulation that is fully implemented on a graphics processing unit (GPU) is described and used to determine low-temperature plasma characteristics at high reduced electric field, E/n, in nitrogen gas. Details of implementation on the GPU using the NVIDIA Compute Unified Device Architecture framework are discussed with respect to efficient code execution. The software is capable of tracking around 10 x 10(6) particles with dynamic weighting and a total mesh size larger than 10(8) cells. Verification of the simulation is performed by comparing the electron energy distribution function and plasma transport parameters to known Boltzmann Equation (BE) solvers. Under the assumption of a uniform electric field and neglecting the build-up of positive ion space charge, the simulation agrees well with the BE solvers. The model is utilized to calculate plasma characteristics of a pulsed, parallel plate discharge. A photoionization model provides the simulation with additional electrons after the initial seeded electron density has drifted towards the anode. Comparison of the performance benefits between the GPU-implementation versus a CPU-implementation is considered, and a speed-up factor of 13 for a 3D relaxation Poisson solver is obtained. Furthermore, a factor 60 speed-up is realized for parallelization of the electron processes. (C) 2014 AIP Publishing LLC.

Journal

Imaging of Explosive Emission Cathode and Anode Plasma in a Vacuum-Sealed Vircator High-Power Microwave Source at 250 A/cm2

Authors: Jonathan M. Parson; John J. Mankowski; James C. Dickens; Andreas A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6905850

Abstract: Cold cathode operation under high current densities leads to explosive electron emission (EEE) that contributes to early A-K gap closure. Hence, inconsistent vacuum conditions and, if utilized in a high power microwave device, degradation of microwave output power are observed. The EEE centers are known to produce localized plasmas on the surface of the cathode that release and ionize the electrode material. Further, low melting point material in the anode is released due to electron bombardment accompanied by a significant surface temperature increase. Postmortem analysis has revealed particles up to 50 μm in diameter embedded in the opposite electrode. High speed ICCD imaging during A-K gap operation enabled resolving the plasma's spatial characteristics in time. Images of cathode and anode plasma during the operation of a virtual cathode oscillator at 250 A/cm2 under ultrahigh vacuum conditions are presented.

Journals

Influence Of Vuv Illumination On Breakdown Mechanics: Pre-Ionization, Direct Photoionization, And Discharge Initiation

Authors: Stephens, J; Fierro, A; Dickens, J; Neuber, A

PDF: https://iopscience.iop.org/article/10.1088/0022-3727/47/32/325501/pdf

Abstract: A microdischarge (MD) vacuum ultraviolet (VUV) light source is fired onto a N-2-NO (99.92 : 0.08%) target gas. The minor gas constituent, NO, was chosen for its ionization potential (9.23 eV) and photoionization cross-section (1.4 x 10(-18) cm(2)) at the wavelength of interest (121.6 nm, 10.2 eV). The result is a plasma generated entirely by volume photoionization in a N-2-NO background. Using a very low electric field amplitude, charge carriers are drifted though the photoplasma at picoampere levels, serving as a non-invasive diagnostic. Using a simple one-dimensional fluid approximation for the low electric field condition, theoretical predictions of photoplasma current were found to be in meaningful agreement with experimental data. The impact of direct photoionization and pre-ionization on nanosecond timescale high voltage breakdown yielded two primary observations: (1) a significant reduction in the formative delay time necessary for spark formation, and (2) almost complete elimination of the statistical delay time. Again utilizing one-dimensional fluid approximations, reasonable agreement between experimental and simulated breakdown voltage was observed. Utilizing the same VUV source to illuminate a HV spark gap biased to about 95% self-breakdown voltage revealed that direct volume photoionization alone was insufficient to trigger breakdown of the high voltage gap. However, permitting electrode illumination, the same source was found to be capable of triggering breakdown in the undervoltaged gap, albeit with a large temporal jitter.

Journal

Measurement and simulation of pulsed plasma development at medium pressure in a non-uniform field

Authors: Andrew Fierro; James Dickens; Andreas Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7287318

Abstract: The development of plasma in a medium pressure (50 torr) environment in nitrogen was studied by simulation and measurement under the influence of non-uniform, pulsed electric fields. A GPU-accelerated, 3-dimensional particle-in-cell (PIC)/Monte Carlo Collision (MCC) simulation code was written utilizing the CUDA platform to simulate pulsed plasma development in a nitrogen environment and uncover the transient plasma characteristics in detail. The simulation provides significant speed-up over the CPU equivalent implementations. Experimentally, a needle-protrusion (1.5 mm in length, 200 μm tip radius) opposite a brass ground plane with the distance between needle-tip and wall held at 1.5 mm provided a non-homogeneous field. Excitation of the needle-plane gap was achieved with a ~100 ns rise-time high-voltage pulser with a peak voltage of 30 kV. Diagnostics included time-resolved nanosecond gated imaging for light intensity measurements and high speed electrical probes for timing. A time series of the plasma formation captured with a 5 ns camera gate revealed a mostly uniform expanding plasma cloud from the needle tip.

Conferences

Micrometer-Resolution High Speed Imaging of Pulsed Microdischarge Ignition

Authors: J. C. Stephens; A. S. Fierro; J. C. Dickens; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6837539

Abstract: The application of a short, pulsed excitation is known to allow for higher power deposition into microdischarges without the onset of instabilities. Here, a MOSFET-based high voltage pulser is used to drive a 50-torr argon microdischarge with short pulsed currents of ~75 A, with <;100-ns full-width at half-maximum, and a repetition rate of 1 MHz. With this excitation, an average power density of ~1013 W/m3 is achieved, with a peak power density~3.1014 W/m3. A high speed iCCD camera is used to observe ignition processes and confirm the absence of unstable operation. The images were taken using a 5-ns gate time with a spatial resolution of ~2.5 μm.

IEEE Journals

Nanosecond, Repetitively Pulsed Microdischarge Vacuum Ultraviolet Source

Authors: Stephens, J; Fierro, A; Walls, B; Dickens, J; Neuber, A

PDF: https://aip.scitation.org/doi/10.1063/1.4866040

Abstract: A microdischarge is driven by short pulses (80 ns FWHM) with peak current levels up to 80 A, with a repetition frequency of 1 MHz (1 pulse/mu s) allowing for similar to 550W input power. Experiments in pure argon (Ar-2*, 127 nm) and argon-hydrogen (Lyman-alpha, 121.6 nm) were conducted. Using short pulses, the argon excimer emission was not observed. Alternatively, Ar-H-2 operated at both higher power and efficiency (0.63%) whenever pulsed. Using Ar-H-2, the experiments result in an average generated vacuum ultraviolet power just above 3.4W with a peak power of 42.8 W, entirely at Lyman-alpha. (C) 2014 AIP Publishing LLC.

Journal

Operation of a 500 kV, 4 kA Marx generator at 500 Hz rep-rate

Authors: M. B. Taylor; P. M. Kelly; J. M. Parson; C. Lynn; J. C. Dickens; A. A. Neuber; J. J. Mankowski; J. . -W. B. Bragg; S. Calico; M. Scott

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7287288

Abstract: A 42 J, 10-stage pulse forming network (PFN) Marx generator capable of producing a 500 kV, 50 ns full-width-half-max (FWHM), ~5 ns rise time pulse into an open load at a rep-rate of 500 Hz has been designed for use as a pulsed power source for a reflex triode virtual cathode oscillator (vircator). Rayleigh PFNs are used in place of discrete capacitors for each stage of the 10-stage Marx generator. Effort was taken to minimize parasitic inductance such that the quality of the pulse shape is maintained as much as possible. In order to rep-rate the Marx generator, a trigatron-based triggering scheme is used to initiate erection of the Marx generator. A 20 ns risetime, 24 kV solid-state pulse trigger generator capable of operating at high repetition rates is used to drive the trigatron. The required charge rate for a 500 Hz pulse repetition frequency (PRF) for the Marx generator is 24 kW. Repetitive operation requires additional design considerations that would be irrelevant to single pulse firing. Pressurized air is jetted across the spark gaps by means of built-in gas manifolds to remove remaining ionized gas between each pulse and prevent premature erection during the subsequent charging cycle. The built-in gas manifolds were designed using a hydrodynamic simulation to ensure equal flow rate across each of the spark gaps and equal pressure along the length of the tube chamber.

IEEE Conferences

Optimization of shock intensities generated by high current exploding wires

Authors: J. Stephens; D. Ryberg; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7012397

Abstract: Summary form only given. A 400 μF capacitor bank, charged as high as 3.5 kV (2.45 J) is used to drive an exploding wire in air with up to 10 s kA over a 100 s of microsecond timescale. Utilizing a short wire with 286 μm diameter enables generating an intense shockwave with overpressures on the order of 1 psi (6.9 kPa). Investigation of the energy dependence of the overpressure magnitude was completed by both varying the initial capacitor voltage, as well as parasitically introducing additional resistive dampening into the circuit. Additionally, variation in both capacitance and inductance were made in order to observe the effect of varying the driving source timescale on generated overpressure. Optimization of the exploding wire load involved exploring various materials, radii, length, as well as the number of exploding wires. Preliminary theoretical predictions are made using the Sandia National Laboratories ALEGRA-MHD software. Theoretical and experimental results are benchmarked against one another to assess the accuracy of the theoretical predictions.

IEEE Conferences

Overview of high voltage 4H-SiC photoconductive semiconductor switch efforts at texas tech university

Authors: D. Mauch; C. White; D. Thomas; A. Neuber; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7287198

Abstract: Recent advances and the current state-of-the-art for high speed 4H-SiC photoconductive semiconductor switches (PCSS) developed at Texas Tech University are summarized. A performance comparison of multiple generations of switch designs is also presented. These devices have experimentally demonstrated the capability of blocking DC electric fields up to 705 kV/cm (<;0.1 mA leakage current), rise times of 0.63 ns (20/80), and switching 20 kV at 250 A with a di/dt of 75 kA/us at a burst repetition frequency of 65 MHz. Findings and optimizations pertaining to device geometry, sub-contact doping, contact thickness, triggering wavelength, and electron irradiation are presented. Device modeling and experimental results investigating current issues with device lifetime are presented as well.

IEEE Conferences

Performance of St707 getter material in a rep-rated high power microwave sealed-tube vircator under UHV conditions

Authors: P. Kelly; J. M. Parson; C. Lynn; M. Taylor; J. C. Dickens; A. Neuber; J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7012655

Abstract: Summary form only given. This study focuses on the use of St707 non-evaporable getter (NEG) material in a high power microwave (HPM) sealed-tube virtual cathode oscillator (vircator) operated at 500 Hz repetition rate. High-current pulsed operation releases gases trapped within the bulk materials and gas monolayers on material surfaces, leading to localized plasma production in the A-K gap. This can lead to gap closure, shorten the duration of microwave emission, and spoil vacuum. A single current pulse increases the chamber pressure to the low 10-6 Torr range from an initial background pressure in the low 10-9 Torr range, desorbing approximately 1014 particles. At 500 Hz operation, a sufficiently large pumping speed (~2,500 L/s) is necessary to evacuate desorbed particles from the vircator volume during consecutive shots. Previous work has identified hydrogen (H, H2) as the main outgassing species during vircator operation, with contributions from CH4, N2, CO, CO2, and Ar as the other primary gas constituents[1]. The St707 NEG pumps shows an affinity for pumping hydrogen, making it a suitable choice to adsorb vircator outgassing species, of which hydrogen is an order of magnitude greater than any other gas species. Previously, without the presence of NEG material, degradation of microwave output power from the vircator has been observed during subsequent shots at 1 Hz, 10 second burst mode operation. Subsequently, an increase in chamber pressure from 1.25×10-6 Torr on the first shot to 10-5 Torr on the tenth shot has been experimentally observed. This paper details the performance of the St707 NEG material (70% Zr, 24.6% V, 5.4% Fe) for maintaining UHV conditions during rep-rated vircator operation. Pumping characteristics of multiple St707 NEG pumps in the presence of rep-rated high-current pulses are presented. Diagnostic results obtained with a residual gas analyzer to observe individual gas constituents and two inverted magnetron cold cathode gauges for absolute pressure are utilized to analyze vircator and getter performance in detail.

IEEE Conferences

Pulse generator development for low impedance loads

Authors: M. Walls; J. Dickens; J. Mankowsi; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7012301

Abstract: Summary form only given. An eleven stage flat top type output Marx utilizing sparkgap switches is operated to produce a desired 500 kV output at 10 Hz rep-rate with > 500 J pulse energy to drive a ~ 20 Ohm load. While this Marx generator utilizes custom-designed spark gaps, the significant progress in semi-conductor pulsed switching technology is evaluated through PSICE modeling of the semiconductor switches integrated into the Marx electrical model. The switches are experimentally evaluated at conditions that a single switch (stack) would experience in a full Marx generator. Alternatively to the Marx topology, the potential benefits of choosing a linear transformer driver (LTD) as a HPM pulsed power driver are evaluated. We note that the main advantage for the LTD is the savings in insulation material and size; the same semiconductor switches are utilized. The potential benefits of such a generator include significant reduction of electromagnetic noise, increased lifetime, improved reliability, and reduced maintenance.

IEEE Conferences

Pulsed microdischarge, 121.6 nm VUV source with 40 watt peak power

Authors: J. Stephens; A. Fierro; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7012344

Abstract: Summary form only given. A micro hollow cathode discharge VUV source, with time averaged power above 3 watts, and peak power above 40 watts is presented1. Such operation is achieved by driving the microdischarge (MD) in the arc mode where high electron densities and low discharge impedances exist. Improved theoretical estimations regarding the timescales of arc formation are presented. With typical electrical sources, the arc regime is associated with a collapse of the potential and poor coupling of energy. However, the pulsed driver utilized in this study features a low output impedance, thus sustaining a reasonable voltage across the MD while simultaneously delivering 10s of amperes when the arc mode is achieved. This allows for time averaged input power on the order of 550 watts. Gas mixtures such as Ar-H2 (99.7%/0.3% by volume) have demonstrated strong VUV emission at Lyman-α (121.6 nm), with measured power levels exceeding 40 watts peak.This study details the influence of the MD performance under various drive modes. Utilizing a pulse forming line based driver the behavior of the MD under 10 ns excitation and various repetition frequencies, with and without DC bias are presented. The MOSFET based low impedance driver, enables investigating the operation of the MD under high average input power. We will demonstrate the feasibility of utilizing the developed MD to achieve volume pre-ionization in appropriate target gases.

IEEE Conferences

REP-rate operation of a ∼200 KV sealed-tube reflex-triode vircator at ∼200 A/cm2

Authors: J. M. Parson; J. -W. B. Bragg; M. Taylor; D. Barnett; P. Kelly; C. F. Lynn; S. Holt; J. C. Dickens; A. A. Neuber; J. J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7012435

Abstract: Thermal limitations of anode and cathode materials have shown to negatively impact operation of cold-cathode high-power microwave (HPM) sources. High pulse-repetition-frequency (PRF) operation of these devices exacerbates the problems already experienced in single shot mode where cold-cathode devices, specifically carbon fiber cathodes, are plagued by plasma formation on the anode and cathode followed by plasma/gas expansion that causes impedance collapse of the anode-cathode (A-K) gap. Hence, for frequency stable, repetitive operation, cold-cathode HPM devices require the use of thermally robust electrode materials and ultra-clean surfaces, leading to repeatable tube operation. This study focuses on burst-mode operation of an HPM sealed tube reflex-triode virtual-cathode-oscillator (vircator) for PRFs greater than 100 Hz. The vircator is driven by a 54 J, ∼200 kV Marx generator with an approximate pulse width of 50 ns FWHM, and the vircator chamber has an empty volume of approximately 5 L with background pressures in the low 10−9 Torr. The anode materials studied include grade-1 titanium (TiG1), nickel 201L (Ni201L), and stainless steel 316L (SS316L); all in combination with a carbon fiber cathode. Empirically observed outgassing characteristics in conjunction with anode thermal modeling are presented under single-shot and rep-rate conditions. In addition, scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX) techniques were employed to investigate anode and cathode surface integrities before and after vircator operation.

IEEE Conferences

Radiation from SiC PCSS driven gyromagnetic nonlinear transmission line high power microwave source

Authors: D. V. Reale; D. Mauch; J. M. Johnson; A. A. Neuber; J. C. Dickens; J. J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7287223

Abstract: An all solid-state high power microwave (HPM) source is constructed using a photoconductive semiconductor switch (PCSS) based HV pulse generator to drive a sulfur hexaflouride (SF6) insulated coaxial ferrimagnetic nonlinear transmission line (NLTL) which feeds a TEM horn antenna. The PCSS was fabricated from high purity semi-insulating (HPSI) 4H-SiC and is illuminated with 2 mJ from a frequency tripled Nd:YAG laser at 355 nm with a 7 ns FWHM. Fixed fiber optic delay lines are utilized to generate a burst of four optical pulses from a single solid-state laser source for rep-rate operation. The input to the NLTL is an adjustable pulse from 3 kV to 6 kV with sub-ns rise time and the resulting output of the NLTL is radiation in the L-band to S-band regime with RF power from 100–200 kW depending on charge voltage. A Rexolite® insulated zipper transition, in which the inner conductor of the coax is gradually exposed, is used at the output of the NLTL to transition from a coaxial structure to parallel plate structure in order to feed a free space TEM horn. The zipper transition and feed section of the TEM horn are potted using Sylgard® 184 silicone elastomer to prevent breakdown at the antenna feed and maintain a homogenous dielectric constant for the transition region. Radiated waveforms are presented for several charge voltages and bias conditions.

IEEE Conferences

Reduction of high power microwave breakdown delay times using multiple passes through a TE111 resonator

Authors: S. Beeson; J. Dickens; A. Neuber; S. Lin

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7012670

Abstract: Summary form only given. The delay time between the rising edge of a high power microwave (HPM) pulse and plasma formation in a gas at close to atmospheric pressure is studied for a multi-pass geometry. A fundamental lower limit of the breakdown delay time is the formative delay time, defined as the time it takes for the exponentially rising electron density to reach the critical electron density for which the EM wave begins to reflect and attenuate; which is on the order of 10's to 100's of nanoseconds for the conditions of interest. The goal of this research was to surpass this limit by making two passes through the generated plasma with the HPM pulse. That is, an external structure is utilized to time delay the HPM pulse on itself for a second pass through a gas cell.

IEEE Conferences

Rep-Rate Operation Of A ~200 Kv Sealed-Tube Reflex-Triode Vircator At ~200 A/Cm<Sup>2</Sup>

Authors: J. M. Parson; J. -W. B. Bragg; M. Taylor; D. Barnett; P. Kelly; C. F. Lynn; S. Holt; J. C. Dickens; A. A. Neuber; J. J. Mankowski

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7012435

Abstract: Thermal limitations of anode and cathode materials have shown to negatively impact operation of cold-cathode high-power microwave (HPM) sources. High pulse-repetition-frequency (PRF) operation of these devices exacerbates the problems already experienced in single shot mode where cold-cathode devices, specifically carbon fiber cathodes, are plagued by plasma formation on the anode and cathode followed by plasma/gas expansion that causes impedance collapse of the anode-cathode (A-K) gap. Hence, for frequency stable, repetitive operation, cold-cathode HPM devices require the use of thermally robust electrode materials and ultra-clean surfaces, leading to repeatable tube operation. This study focuses on burst-mode operation of an HPM sealed tube reflex-triode virtual-cathode-oscillator (vircator) for PRFs greater than 100 Hz. The vircator is driven by a 54 J, ~200 kV Marx generator with an approximate pulse width of 50 ns FWHM, and the vircator chamber has an empty volume of approximately 5 L with background pressures in the low 10-9 Torr. The anode materials studied include grade-1 titanium (TiG1), nickel 201L (Ni201L), and stainless steel 316L (SS316L); all in combination with a carbon fiber cathode. Empirically observed outgassing characteristics in conjunction with anode thermal modeling are presented under single-shot and rep-rate conditions. In addition, scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX) techniques were employed to investigate anode and cathode surface integrities before and after vircator operation.

Conference Paper/Presentation

Rep-rate operation of a 300 kV, high-power microwave sealed-tube vircator

Authors: J. M. Parson; C. F. Lynn; J. -W. B. Bragg; P. Kelly; M. Taylor; D. Barnett; S. Holt; J. C. Dickens; A. A. Neuber; J. J. Mankowski; M. C. Scott; S. E. Calico

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7287274

Abstract: Thermal limitations of anode materials are known to impose limits on rep-rate operation of cold-cathode high-power microwave (HPM) sources. This study focuses on performance of pyrolytic graphite (PG) anodes at a 500 Hz burst-mode operation in a reflex-triode virtual-cathode-oscillator (vircator). In most experiments, a 42 J, 300 kV pulse forming network (PFN) based Marx generator with an approximate pulse width of 50 ns full-width-half-max (FWHM), was utilized to drive the vircator. Rep-rated operation of the vircator exacerbates the problems already experienced in single-pulsed mode where vircators are plagued by plasma formation on the anode and cathode followed by plasma/gas expansion that causes degradation of anode materials. Hence, for frequency-stable, repetitive operation, vircators require the use of thermally robust electrode materials and ultra-clean vacuum surfaces, leading to repeatable diode operation. This contribution presents thermal modeling of anode heating and experimental electrical behavior of vircator rep-rate operation.

IEEE Conferences

Selected pulsed power efforts in US academia over the past two decades

Authors: A. Neuber; J. Dickens; J. Mankowski; L. Hatfield; H. Krompholz; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7012489

Abstract: We review the past 20 years of progress in pulsed power science and technology at Texas Tech University, a US academic institution, specifically focusing on efforts that came to fruition with the support of Dr. Robert Barker, AFOSR.

IEEE Conferences

Semiempirical Wide-Range Conductivity Model With Exploding Wire Verification

Authors: Stephens, J; Dickens, J; Neuber, A

PDF: https://pubmed.ncbi.nlm.nih.gov/25353899/

Abstract: Based on well-established physical relationships, a semiempirical set of equations dictating the electrical conductivity of dense, strongly coupled, partially ionized copper is presented. With the empirical coefficients, the model is tuned to experimental conductivity data obtained from exploding wire experiments [A. W. DeSilva and J. D. Katsouros, Phys. Rev. E 57, 5945 (1998)]. The result is a wide-range conductivity model, with demonstrated accuracy from room temperature-density conditions to 0.01 g/cm(3) and 30 kK. Using magnetohydrodynamic simulation the ability to utilize the conductivity model for predictive simulations is demonstrated. A complete electrical conductivity dataset for copper has been made available to the public.

Journal

System For Time-Discretized Vacuum Ultraviolet Spectroscopy Of Spark Breakdown In Air

Authors: Ryberg, D; Fierro, A; Dickens, J; Neuber, A

PDF: https://aip.scitation.org/doi/pdf/10.1063/1.4897295

Abstract: A system for time-discretized spectroscopic measurements of the vacuum ultraviolet (VUV) emission from spark discharges in the 60-160 nm range has been developed for the study of early plasma-forming phenomena. The system induces a spark discharge in an environment close to atmospheric conditions created using a high speed puff value, but is otherwise kept at high vacuum to allow for the propagation of VUV light. Using a vertical slit placed 1.5 mm from the discharge the emission from a small cross section of the discharge is allowed to pass into the selection chamber consisting of a spherical grating, with 1200 grooves/mm, and an exit slit set to 100 mu m. Following the exit slit is a photomultiplier tube with a sodium salicylate scintillator that is used for the time discretized measurement of the VUV signal with a temporal resolution limit of 10 ns. Results from discharges studied in dry air, Nitrogen, SF6, and Argon indicate the emission of light with wavelengths shorter than 120 nm where the photon energy begins to approach the regime of direct photoionization. (C) 2014 AIP Publishing LLC.

Journal

Temporally Resolved Electron Density Of A Repetitive, Nanosecond Pulsed Microdischarge

Authors: Stephens, J; Fierro, A; Dickens, J; Neuber, A

PDF: https://iopscience.iop.org/article/10.1088/0022-3727/47/46/465205

Abstract: Using high speed spectroscopic diagnostics, temporally resolved optical emission spectroscopy is performed on a nanosecond, repetitively pulsed microdischarge. The microdischarge operates in an argon-hydrogen gas mixture (99%/1%) to provide a Lyman-alpha vacuum ultraviolet emission. Based on the Stark broadening of the 486.1 nm, Balmer-beta hydrogen transition, the temporally resolved electron density was determined. Experimental electron density data are compared with the results of a 0D rate equation model. Peak electron density is estimated to be 5.6 . 10(15) cm(-3), corresponding to a similar to 0.25% degree of ionization. Using the approximate experimental ionization rate, the electron temperature is estimated to be similar to 3.5 eV.

Journal

2013

A Compact 45 Kv Curve Tracer With Picoampere Current Measurement Capability

Authors: Sullivan, WW; Mauch, D; Bullick, A; Hettler, C; Neuber, A; Dickens, J

PDF: https://aip.scitation.org/doi/10.1063/1.4794734

Abstract: This paper discusses a compact high voltage curve tracer for high voltage semiconductor device characterization. The system sources up to 3 mA at up to 45 kV in dc conditions. It measures from 328 V to 60 kV with 15 V resolution and from 9.4 pA to 4 mA with 100 fA minimum resolution. Control software for the system is written in Microsoft Visual C# and features real-time measurement control and IV plotting, arc-protection and detection, an electrically isolated universal serial bus interface, and easy data exporting capabilities. The system has survived numerous catastrophic high voltage device-under-test arcing failures with no loss of measurement capability or system damage. Overall sweep times are typically under 2 min, and the curve tracer system was used to characterize the blocking performance of high voltage ceramic capacitors, high voltage silicon carbide photoconductive semiconductor switches, and high voltage coaxial cable. (C) 2013 American Institute of Physics. [http://dx.doi.org/10.1063/1.4794734]

Journal

A high-power transient coaxial power combiner for nonlinear transmission lines

Authors: N. R. Gonsalves; D. V. Reale; J.-W. B. Bragg; W. W. Sullivan; A. A. Neuber; S. L. Holt; J. J. Mankowski; J. C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6627665

Abstract: Recent work on Coaxial Ferrimagnetic Nonlinear Transmissions Lines (NLTL) has been focused on developing an array of NLTLs for use as a solid-state High Power Microwave (HPM) source. The pulsed output of an NLTL requires a combiner that can combine transient signals at voltage levels up to 50 kV. Existing combiner designs found in literature require resonant structures to achieve efficient power combination. The presented coaxial combiner is an in-plane structure designed to combine two 50 Ω transmission lines into a single 25 Ω coaxial line output which then uses a logarithmic taper to transition back to 50 Ω. The combiner design was simulated using a transient Finite Element Method (FEM) model in COMSOL Multiphysics® and experimental results are compared with simulation. A 4-way combiner based on an in-plane 2-way design is simulated and the field stresses are examined to determine maximum electric field levels encountered in the structure. This enabled estimating the associated maximum voltage level that the structure is able to support.

Conferences

A passive method for determining plasma dissociation degree using vacuum UV self-absorption spectroscopy

Authors: G. Laity; A. Fierro; L. Hatfield; J. Dickens; A. Neuber; K. Frank

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6635196

Abstract: Summary form only given. There has been a continued interest in utilizing streamer and spark discharges for new technologies that require low temperature plasma generation at atmospheric pressure, but diagnostics of these plasmas typically require external sources of probing radiation such as UV lamps or laser systems. Specifically, it is desired to measure the dissociated gas density from pulsed surface flashover plasmas, without the use of potentially invasive optical techniques such as two-photon absorption laser induced fluorescence (TALIF) spectroscopy, which may artificially increase the dissociation degree. We demonstrate a method for determining the dissociated gas density of N and H atoms in an N2/H2 surface flashover plasma by passively monitoring the self-absorption of intrinsic radiation produced by the 2s2 2p2 3s→2s2 2p3 NI transition(s) at 120.0 nm, and the 2p→ls HI Lyman-α transition at 121.57 nm. This radiation is partially trapped by the spark plasma, assumed to be of Gaussian cylindrical shape with 500 μm diameter. The resulting emission line shapes can be calculated by inferring the plasma temperature, gas mixture, and the estimated dissociated atom density of each species in the plasma volume of measurement. For example, 80%/20% N2/H2 discharges with a measured electron temperature of ~3.0 eV produce peak dissociated concentrations of 2% and 9% for atomic N and H, respectively, during the spark phase ~100 ns after voltage collapse. By assuming the quasi-contiguous approximation of the Holtsmark micro-field due to local electron perturbation of the HI radiators, the Stark line width of Lyman-α radiation yields electron densities on the order of 1018 cm3 during the spark phase. This self-absorption method has been extended to provide density information of surface flashover plasmas in air environments by passively monitoring the 2s2 2p3 3s→2s2 2p4 OI transitions) at 130.2 nm / 130.5 nm / 130.6 nm, which yield peak dissociated concentrations of 20% and 7% for atomic O and N, respectively.

IEEE Conferences

All Solid-State High Power Microwave Source With High Repetition Frequency

Authors: Bragg, JWB; Sullivan, WW; Mauch, D; Neuber, AA; Dickens, JC

PDF: https://aip.scitation.org/doi/10.1063/1.4804196

Abstract: An all solid-state, megawatt-class high power microwave system featuring a silicon carbide (SiC) photoconductive semiconductor switch (PCSS) and a ferrimagnetic-based, coaxial nonlinear transmission line (NLTL) is presented. A 1.62 cm(2), 50 kV 4H-SiC PCSS is hard-switched to produce electrical pulses with 7 ns full width-half max (FWHM) pulse widths at 2 ns risetimes in single shot and burst-mode operation. The PCSS resistance drops to sub-ohm when illuminated with approximately 3 mJ of laser energy at 355 nm (tripled Nd:YAG) in a single pulse. Utilizing a fiber optic based optical delivery system, a laser pulse train of four 7 ns (FWHM) signals was generated at 65 MHz repetition frequency. The resulting electrical pulse train from the PCSS closely follows the optical input and is utilized to feed the NLTL generating microwave pulses with a base microwave-frequency of about 2.1 GHz at 65 MHz pulse repetition frequency (prf). Under typical experimental conditions, the NLTL produces sharpened output risetimes of 120 ps and microwave oscillations at 2-4 GHz that are generated due to damped gyromagnetic precession of the ferrimagnetic material's axially pre-biased magnetic moments. The complete system is discussed in detail with its output matched into 50 Omega, and results covering MHz-prf in burst-mode operation as well as frequency agility in single shot operation are discussed. (C) 2013 AIP Publishing LLC.

Journal

An expirimental system for the measurement of vacuum UV below 115 nm from pulsed plasma in an N2/O2 environment

Authors: D. Ryberg; G. Laity; A. Fierro; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6635150

Abstract: Summary form only given. Limited experimental literature exists for measuring radiation with wavelengths shorter than 115 nm primarily due to the difficulty associated with measuring VUV radiation due to the high absorption in molecular oxygen and optical materials. Furthermore, there is an increasing interest in quantifying the role of this radiation in the generation of low temperature plasmas. This paper describes a system for studying the early mechanisms of vacuum UV generation below 115 nm by inducing breakdown in an air environment near atmospheric pressure. However to avoid the attenuating effects of O2, the experiment is set up such that the pressure drops to deep vacuum (i.e. ~10-6 torr) within a distance of several millimeters from the location of breakdown without the use of a solid barrier. In order to perform this measurement, the experiment consists of an enclosure at high vacuum, a pair of electrodes, and a micro puff valve. The puff value releases an above atmospheric pressure wave of air in the vicinity of the electrodes, whose differential electrical potential is then raised to about 20kV with a rise-time on the order of 100 nanoseconds. With application of the pulsed electric field, the radiation emitted from the excited species escapes the very localized puff of air and propagates through the high vacuum largely unattenuated where it is resolved by vacuum UV-sensitive optics and detectors. With this setup, the generation of vacuum UV radiation below 115 nm can be studied in detail and in the future the data recorded with this system will be used in our modeling approaches for further understanding of low temperature plasma generation.

IEEE Conferences

Bias field controlled phasing of Ferrimagnetic Coaxial Nonlinear Transmission Lines

Authors: David Reale; J.-W. Braxton Bragg; Shad Holt; Andreas Neuber; John Mankowski; James Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6633209

Abstract: Coaxial Ferrimagnetic Nonlinear Transmission Lines (NLTL) are utilized as all solid state High Power Microwave (HPM) sources with virtually fixed phase relationship between input voltage pulse and output rf wave. Since the output power of a single NLTL at a given frequency, and of a given size, is limited by the effect of line dimensions as well as charge voltage on operating frequency, we employ an NLTL array to achieve higher power levels. To operate in microwave generation mode the ferrite domains are aligned along the axial direction of the NLTL using a biasing magnetic field generated by a dc current driven solenoid. This biasing method also provides a means of controlling the line delay by adjusting the magnetization of the ferrites using an auxiliary delay coil. By utilizing the delay coil and the primary biasing coil together on an NLTL, the operating frequency can be locked at a given frequency while the delay of the line can be independently adjusted. The relationship between the delay coil field and the corresponding temporal delay is investigated, and two NLTLs fed by identical voltage pulse shapes are combined using the phase control method described.

Conferences

Bias field controlled phasing of ferrimagnetic coaxial nonlinear transmission lines

Authors: D. V. Reale; J.-W. B. Bragg; S. L. Holt; A. A. Neuber; J. J. Mankowski; J. C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6627412

Abstract: Coaxial Ferrimagnetic Nonlinear Transmission Lines (NLTL) can be utilized as High Power Microwave (HPM) sources. The output power of a single NLTL at a given frequency, and of a given size, is limited by the effect of line dimensions and charge voltage on operating frequency. Therefore, to achieve higher power levels, an array is required. To operate in microwave generation mode the ferrite domains are aligned along the axial direction of the NLTL using a biasing magnetic field generated by a dc current driven solenoid. This biasing method also provides a means of controlling the line delay by adjusting the magnetization of the ferrites using an auxiliary delay coil. By utilizing the delay coil and the primary biasing coil together on an NLTL, the operating frequency can be locked at a given frequency while the delay of the line can be independently adjusted. The relationship between the delay coil field and the corresponding temporal delay is investigated and two NLTLs are combined using the phase control method described.

Conferences

Burst mode operation of >100 MW reflex triode vircator

Authors: C. F. Lynn; J. Parson; P. Kelly; M. Taylor; J. Mankowski; J. Dickens; A. Neuber; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6635085

Abstract: Summary form only given. Vircators are high power microwave sources which operate at frequencies approximately proportional to the plasma frequency of the electron beam as it passes through the anode. As a result, stable frequency operation requires flat top voltage pulses, and diodes which exhibit little variation in impedance over a given pulse duration. However, plasma formation on the anode and cathode followed by plasma expansion causes the effective A-K gap and thus the impedance of the diode to collapse with time. As the impedance collapses current density increases, possibly causing a shift to higher frequency operation. The vircator presently discussed exhibits frequency chirping from 4 to 5.5 GHz during a pulse length of 700 ns when operated with an 8 stage, 1.5 kJ Marx generator that has a pulse shape of an overdamped RLC discharge (assuming arc formation does not occur). However, stable frequency operation is observed with an 8 stage 80 J Marx, each stage constructed from pulse forming networks rather than discrete capacitors. The PFN Marx generator produces a flat top voltage for a 75 ns FWHM pulse; however the energy radiated from the vircator is much lower due to the reduced energy storage of the PFN Marx. Burst mode operation has the potential to improve frequency stability and energy radiated from the vircator. This contribution reports the experimental results of a compact sealed tube vircator operated in burst mode with a repetition rate of up to 100 Hz. The data show voltage and current waveforms during burst cycles as well as microwave waveforms with temporally resolved frequency spectra.

IEEE Conferences

Current capabilities of a low inductance Marx generator for driving a high power microwave source

Authors: Patrick Kelly; Curtis Lynn; Jonathan Parson; Mark Taylor; John Mankowski; Andreas Neuber; James Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6634857

Abstract: The electrical characteristics and current capabilities of a low inductance Marx generator used to drive a high power microwave (HPM) source are described. The operating frequency of many HPM sources is dependent upon various characteristics of the input voltage pulse from the pulsed power generator. Texas Tech University has developed an 8 stage, 80 J Marx generator used to drive HPM sources at repetition rates up to 500 Hz. The Marx generator is constructed using pulse forming networks rather than discrete capacitors. Experimental efforts have shown stable frequency operation of a virtual cathode oscillator (Vircator) source using a low energy, PFN Marx. Efforts were taken to reduce parasitic inductance of the PFN Marx resulting in a voltage pulse with a risetime less than 25ns with 50ns FWHM. Additionally, efforts were taken to improve impedance matching between the PFN Marx and the vircator load. This article presents experimental results of an 80 J Marx at voltages ranging from 150 kV to 250 kV operating in burst mode. Voltage and current waveforms from the Marx are shown as well as some typical results of compact sealed tube vircator operation.

Conferences

Development and characterization of a pulsed micro hollow cathode discharge array

Authors: J. Stephens; B. Loya; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6634980

Abstract: Summary form only given. A high side, high voltage pulser is used to excite a micro hollow cathode discharge (MHCD) geometry with short pulsed voltages adjustable on the order of 100-500 ns, at repetition rates from 10-200 kHz. The goal of this research is to develop an intense, efficient UV/VUV radiation source capable of generating photons of sufficient energy to affect direct photo-ionization in a gaseous volume rather than photoemission from surfaces. The pulser used in this study has experimentally demonstrated to be capable of efficiencies on the order of 80% when delivering power to a 1 KΩ resistive load at 200 kHz repetition rate. The final design is to be compact, and robust, capable of long term rep-rated operation with minimal electrode erosion and dielectric degradation. Present designs involve laser machining a direct bonded copper (DBC) substrate consisting of Cu-Al2O3-Cu. Transient ignition of the MHCD, voltage and current waveforms, and spectral emission are all experimentally studied. A transient, 2-dimensional, cylindrical coordinate (r-z) fluid model is used for the theoretical treatment of the microdischarge. Using known rate coefficients for argon, time and space resolved behavior of discharge under pulsed conditions is presented.

IEEE Conferences

Ferrimagnetic Nonlinear Transmission Lines As High-Power Microwave Sources

Authors: J. -. B. Bragg; J. C. Dickens; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6359866

Abstract: Ferrimagnetic nonlinear transmission lines (NLTLs) have the potential to fill a high-power microwave niche where compact cost-effective sources are lacking. NLTLs utilize nonlinear ferrimagnetic properties and magnetization dynamics to provide ultrafast pulse rise times (100 ps or less) and microwave signals with peak power ranging from kilowatts to hundreds of megawatts. The frequency of operation has been shown to range from 900 MHz up to 5 GHz depending on geometry and external magnetic fields. NLTLs, theoretically, can be pulsed to tens of kilohertz with little to no variance in microwave signal between shots. This paper covers recent advances in ferrimagnetic-based NLTLs, specifically effects of applied and bias magnetic fields on peak power and frequency, as well as temperature dependence.

Journal

Focused Cathode Design To Reduce Anode Heating During Vircator Operation

Authors: Lynn, CF; Dickens, JC; Neuber, AA

PDF: https://aip.scitation.org/doi/10.1063/1.4826209

Abstract: Virtual cathode oscillators, or vircators, are a type of high power microwave device which operates based on the instability of a virtual cathode, or cloud of electrons, which forms when electron current injected into the drift tube exceeds the space charge limited current within the drift tube. Anode heating by the electron beam during vircator operation ultimately limits achievable pulse lengths, repetition rates, and the duration of burst mode operation. This article discusses a novel cathode design that focuses electrons through holes in the anode, thus significantly reducing anode heating by the electrons emitted from the cathode during the first transit through the A-K gap. Reflexing electrons continue to deposit energy on the anode; however, the discussed minimization of anode heating by main beam electrons has the potential to enable higher repetition rates as well as efficiency and longer diode lifetime. A simulation study of this type of cathode design illustrates possible advantages. (C) 2013 AIP Publishing LLC.

Journal

Frequency tunable sealed tube reflex triode vircator

Authors: Mark Taylor; Patrick Kelly; Curtis Lynn; Jonathan Parson; John Mankowski; Andreas Neuber; James Dickens; Magne Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6635087

Abstract: Summary form only given. A virtual cathode oscillator (vircator) is a high power microwave device that exhibits frequency tunability which is inherent to its principle of operation. Two types of electron motion within the vircator generate microwaves (virtual cathode oscillation and reflexing electron motion). Although it is difficult to precisely predict the dominant microwave frequency of a vircator design prior to experimental observation, the oscillation frequency of the virtual cathode is approximately proportional to the plasma frequency of the electron beam as it enters the virtual cathode. Additionally, the reflexing electrons oscillate at a frequency which is inversely proportional to approximately four times the transit time of an electron through the anode-cathode gap (A-K gap). As a result, assuming space charge limited diode operation, the virtual cathode and reflexing electron oscillation frequencies, though different, are proportional to V1/2/d, where d is the gap separation of the A-K gap and V is the accelerating voltage applied to the gap. Thus vircators are tunable via adjusting the A-K gap and varying the applied accelerating voltage. Texas Tech University has developed a sealed tube vircator which radiates approximately 100 MW with an operational frequency of 4GHz. Operating at 4GHz the diode has an A-K gap of 8mm, an accelerating voltage of ~200 k V, and electron beam current of ~3.5kA. Here we present an experimental investigation of the tunability of a reflex triode vircator by varying the A-K gap from 4 mm to 10 mm and accelerating voltages ranging from 150 kV to 250 kV.

Conferences

High voltage solid dielectric coaxial ferrimagnetic Nonlinear Transmission Line

Authors: David Reale; J.-W. Braxton Bragg; Richard Solarski; Andreas Neuber; Shad Holt; John Mankowski; James Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6633210

Abstract: Previously developed coaxial ferromagnetic Nonlinear Transmission Lines (NLTL) relied solely on pressurized Sulfur Hexaflouride (SF6) as high-voltage insulating dielectric medium [1]. While the use of SF6 provides the necessary electric insulation, there are drawbacks including gas storage and pressure fittings that increase system size and add to the design complexity of the NLTLs themselves. We evaluate solid dielectric materials as an alternative. Initial attempts used a standard high voltage (HV) epoxy to pot the NLTL assembly. This method was effective at producing magnetic precession in the NLTL; however, there was a reduction in output power due to the high loss tangent of the epoxy. Sylgard 184, commonly used in solar cells, has been widely used as an HV potting material and has an order of magnitude lower loss tangent than standard HV epoxy at 1 kHz. Samples of HV epoxy and Sylgard 184 are tested in a microwave cavity resonator at 3 GHz to determine their loss tangents. The performance of an NLTL potted with Sylgard 184 is compared to that of the HV epoxy NLTL and the current SF6 insulated NLTL.

Conferences

High voltage solid dielectric coaxial ferrimagnetic nonlinear transmission line

Authors: R. C. Solarski; D. V. Reale; J.-W. B. Bragg; A. A. Neuber; S. L. Holt; J. J. Mankowski; J. C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6627413

Abstract: At the Center for Pulsed Power and Power Electronics, previous coaxial ferrimagnetic Nonlinear Transmission Lines (NLTL) relied solely on pressurized Sulfur Hexafluoride (SF6) as high-voltage insulating dielectric medium [1]. While the use of SF6 provides the necessary electric insulation, there are drawbacks including gas storage and pressure fittings that increase system size and add to the design complexity of the NLTLs themselves. Hence it was deemed necessary to evaluate solid dielectric materials as an alternative. Initial attempts utilized a standard high voltage (HV) epoxy to pot the NLTL assembly. This method was effective at producing magnetic precession in the NLTL; however, there was a reduction in output power due to the high loss tangent of the epoxy. Sylgard 184, commonly used in solar cells, has also found use as an HV potting material. Per datasheet, its loss tangent is an order of magnitude lower compared to standard HV epoxy at 1 kHz. Samples of HV epoxy and Sylgard 184 were tested in a microwave cavity resonator at 3GHz, which yielded their respective loss tangents. The performance of an NLTL potted with Sylgard 184 is compared to that of the HV epoxy NLTL and the earlier SF6 insulated NLTL.

Conferences

Hydrodynamic and magnetohydrodynamic modeling of exploding wires in opening switch type operation

Authors: J. Stephens; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6635217

Abstract: Exploding wires (EWs) are subjected to high current densities of the order of 107 A/cm2 inducing metal vaporization and plasma formation on a microsecond timescale. Single strand EWs, silver and copper, are tested in gaseous media from atmospheric pressure to 790 kPa. To theoretically predict EW behavior, one-dimensional, radially directed cylindrical, Lagrangian coordinate hydrodynamic (HD) and magnetohydrodynamic (MHD) models are applied. Such models require accurate material equation-of-state (EOS) and electrical conductivity data throughout the temperature density range experimentally achieved (ρ=0.1-10 gm/cm3 and T=300-20,000 K). In this study, the Lee-More-Desjarlais (LMD) conductivity, and its quantum molecular dynamic modification (QLMD) are used. The Los Alamos National Laboratory SESAME database is used to provide the EOS parameters. When utilized as an opening switch the metal plasma is exposed to higher electric fields, atypical to traditional exploding wire experiments. Recent studies have shown that the behavior of the strongly coupled plasma in such conditions is reasonably well modeled assuming a semi-empirical electron impact ionization process. The HD and MHD based models are benchmarked against experimental data to confirm their accuracy for predicting the behavior of EWs in an opening switch type operation.

IEEE Conferences

Material Selection Considerations For Coaxial, Ferrimagnetic-Based Nonlinear Transmission Lines

Authors: Bragg, JWB; Dickens, JC; Neuber, AA

PDF: https://aip.scitation.org/doi/abs/10.1063/1.4792214?journalCode=jap

Abstract: The growing need for solid-state high power microwave sources has renewed interest in nonlinear transmission lines (NLTLs). This article focuses specifically on ferrimagnetic-based NLTLs in a coaxial geometry. Achieved peak powers exceed 30 MW at 30 kV incident voltage with rf power reaching 4.8 MW peak and pulse lengths ranging from 1-5 ns. The presented NLTL operates in S-band with the capability to tune the center frequency of oscillation over the entire 2-4 GHz band and bandwidths of approximately 30%, placing the NLTL into the ultra-wideband-mesoband category of microwave sources. Several nonlinear materials were tested and the relationship between NLTL performance and material parameters is discussed. In particular, the importance of the material's ferromagnetic resonance linewidth and its relationship to microwave generation is highlighted. For a specific nonlinear material, it is shown that an optimum relation between incident pulse magnitude and static bias magnitude exists. By varying the nonlinear material's bias magnetic field, active delay control was demonstrated. (C) 2013 American Institute of Physics. [http://dx.doi.org/10.1063/1.4792214]

Journal

Microwave radiation from a SiC PCSS driven gyromagnetic NLTL

Authors: J.-W. Braxton Bragg; William W. Sullivan; David V. Reale; Daniel L. Mauch; Shad Holt; Andreas A. Neuber; John Mankowski; James C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6633211

Abstract: An all solid-state high power microwave system comprised of a photoconductive semiconductor switch (PCSS) and nonlinear transmission line (NLTL) is presented. A single 50 kV 4H-Silicon Carbide (SiC) PCSS switches 7 ns (FWHM) pulses with 2 ns risetime into the gyromagnetic NLTL. The PCSS achieves sub-ohm resistance when illuminated by approximately 3 mJ of laser energy emitted from a tripled Nd:YAG laser (355 nm). Utilizing a fiber optic based optical triggering system enabled generating a train of laser pulses, and burst-mode operation with 65 MHz pulse repetition frequency was achieved. The NLTL sharpens the fast rising pulse from the PCSS and produces MW-class rf power levels at 2-4 GHz. Microwave generation is achieved through stimulation of damped gyromagnetic precession when the static and pulsed external magnetic fields interact with the magnetic moments of the nonlinear ferromagnetic material. The acting nonlinear material is a NiZn composite with dimensions 3 mm × 6 mm (ID × OD). The system is terminated with a wideband antenna consisting of a coaxial to parallel-plate conversion balun which is then immediately flared to provide a linearly-flared TEM horn antenna. The entire length of the compact HPM system measures 1.15 m. Radiation results for single shot and burst-mode operation are presented as well as demonstration of operational frequency control.

Conferences

Performance and characterization of a 20 kV, contact face illuminated, silicon carbide photoconductive semiconductor switch for pulsed power applications

Authors: D. L. Mauch; W. W. Sullivan; A. B. Bullick; A. A. Neuber; J. C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6635034

Abstract: A 20 kV, lateral geometry, contact face illuminated, silicon carbide (SiC) photoconductive semiconductor switch (PCSS) is presented. The SiC PCSS was fabricated from high purity semi-insulating, bulk 4H-SiC (12.7 mm × 12.7 mm × 0.35 mm), in a lateral geometry, (0.6 mm gap) with both the anode and cathode contacts located on the same face of the device. The device was illuminated with light from a tripled Nd:YAG laser (355 nm-7 ns FWHM) entering from the contact face. The device demonstrated sub-ohm on-state resistance for laser pulse energies in the mJ range, and micro-amp leakage currents at 20 kVdc in the off-state. Voltage hold-off and low leakage currents in the off state were achieved through high energy electron beam irradiation of the bulk material. The switch's geometry and packaging are discussed, along with experimental switching and blocking characteristics.

IEEE Conferences

Performance of NEG getter materialin a sealed reflex-triode vircator at 225 A/cm2

Authors: P. Kelly; J. M. Parson; C. F. Lynn; J. J. Mankowski; J. C. Dickens; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6635086

Abstract: Summary form only given. This study focuses on the use of non-evaporable getter (NEG) materials in a high power microwave (HPM) virtual-cathode oscillator (vircator). The vircator has a background pressure in the low 10-9 torr range with a vacuum volume of 5 L backed by a small 20 L/s ion pump. Presently, the source is driven by an 80 J, 300 kV Marx generator with a current density of 225 A/cm2 and pulse width of 100 ns. Initial current pulses increases the chamber pressure to the low 10-6 torr range desorbing approximately 1014 particles1,2. Reduction in the number of particles desorbed decreases an order of magnitude after approximately 2,000 current pulses, with no further noticeable decrease after 10,000 pulses3. The HPM system will eventually be modified to operate at 500 Hz with a pulse width between 10-20 ns. In first order approximations, a pumping speed of 2500 L/s will be needed to pump 1014 particles within 2 ms from a 5 L volume. This corresponds to a surface area of approximately 2400 cm2 for a zirconium-vanadium-iron (ZrVFe) getter material. An introduction of NEG materials into the vacuum chamber will aid in achieving repetitive operation; and preliminary results on the use of the NEG material in the vacuum environment will be presented. A residual gas analyzer (RGA) and an inverted-magnetron cold cathode vacuum sensor are used for the gas diagnostics and are rated to survive the 300°C, 72 hour vircator bake out process.

IEEE Conferences

Plasma Relaxation Mechanics Of Pulsed High Power Microwave Surface Flashover

Authors: Beeson, S; Dickens, J; Neuber, A

PDF: https://aip.scitation.org/doi/abs/10.1063/1.4822343?journalCode=php

Abstract: Microwave transmission and reflection characteristics of pulsed radio frequency field generated plasmas are elucidated for air, N-2, and He environments under pressure conditions ranging from 10 to 600 torr. The pulsed, low temperature plasma is generated along the atmospheric side of the dielectric boundary between the source (under vacuum) and the radiating environment with a thickness on the order of 5 mm and a cross sectional area just smaller than that of the waveguide. Utilizing custom multi-standard waveguide couplers and a continuous low power probing source, the scattering parameters were measured before, during, and after the high power microwave pulse with emphasis on the latter. From these scattering parameters, temporal electron density estimations (specifically the longitudinal integral of the density) were calculated using a 1D plane wave-excited model for analysis of the relaxation processes associated. These relaxation characteristics ultimately determine the maximum repetition rate for many pulsed electric field applications and thus are applicable to a much larger scope in the plasma community than just those related to high power microwaves. This manuscript discusses the diagnostic setup for acquiring the power measurements along with a detailed description of the kinematic and chemical behavior of the plasma as it decays down to its undisturbed state under various gas type and pressure conditions. (C) 2013 AIP Publishing LLC.

Journal

Post pulse recovery of HPM generated plasma at close to atmospheric pressure

Authors: Sterling R. Beeson; James C. Dickens; Andreas A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6635055

Abstract: Summary form only given. We study the recovery of the low temperature plasma generated by a microsecond high power microwave, HPM, pulse in different gases at pressures approaching one atmosphere. The experiment mimics the electrical breakdown at the interface between the vacuum HPM-source environment and the radiating environment (generally held at atmospheric pressure). This low temperature plasma is generated along the surface on the atmospheric side where the high Eeff/p, or reduced effective electric field with pressure, causes high levels of ionization leading to the formation of a highly conductive plasma within the duration of the microsecond pulse. With the maximum HPM pulse repetition rate being highly dependent on the relaxation of this plasma, it is the goal of this study to determine the kinematics and chemistry of this low temperature plasma as it pertains to ion, electron, and excited species densities. For this study, a 2.85 GHz magnetron operating in the TE10 mode of a WR-284 standard waveguide is used to generate a 3 MW, 3 microsecond pulse with a rise time of less than 50 ns that is incident on the dielectric window separating the two environments. The atmospheric side is enclosed in a structure that mimics an open radiation pattern similar to that of current HPM systems. To understand the post-pulse features, two custom multi-standard waveguide couplers were designed to implement and extract a low power 10 GHz CW source into the main waveguide structure while keeping a low insertion loss for the HPM pulse. The results of this power signal (max attenuation values range -10 to -40 dB) along with a 1D plane wave excited plasma model is used to infer the temporal average electron density (specifically the longitudinal integral of the surface plasma density) at a range of pressures and different gases, typically 10-400 torr for air, N2, Ar, and He. The peak electron density and loss rates are then correlated with diffusion lengths, recombination and attachment rates given in literature to ascertain the dominant plasma relaxation path and species along with a means to extrapolate the time required to relax to a nominal background electron density. For instance, the dominant electron loss process in 90 torr air is attachment with a frequency of 121 kHz and peak electron density of ~1013 cm-3 resulting in relaxation times of a few hundred microseconds while in N2, the dominant process soon after the pulse is determined to be 2-body dissociative recombination.

Conferences

Rapid capacitor charger and battery system for portable pulsed power applications

Authors: S. L. Holt; J. C. Dickens; J. J. Mankowski; G. Rodriquez

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6635187

Abstract: The design of a scalable, burst-mode rapid capacitor charger and a high power battery system will be discussed. The design is scalable up to 40 kW output power and operates at 50 k V. The system is powered by a Lithium Ion Polymer (LiPo) battery pack and includes a battery management system. The topology is derived from a 5 kV, 3 kJ/s battery power capacitor charger that was previously demonstrated. This smaller charger occupied a volume of 1.5 L including batteries and demonstrated a 2 kW/L average power density over a 1 s burst. This power density is five to ten times higher than commercially available systems. The performance of this previous design was limited by strict form factor restrictions (1.5 L, 6" diameter). The new design is intended to match or exceed the power density of the previous design due to reduced form factor restrictions. Electrical and mechanical design, component selection, and circuit simulations will be presented.

IEEE Conferences

Selective electron beam irradiation of high purity semi-insulating 4H silicon carbide substrates to characterize the effects on photoconductive semiconductor switch operation

Authors: A. Bullick; D. Mauch; W. Sullivan; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6633401

Abstract: High energy electron beam irradiation of bulk SiC creates crystal defects within the material which act as deep traps. These deep traps capture charge carriers and in turn increase the resistivity/blocking voltage of SiC photoconductive semiconductor switches (PCSS). Irradiation has been reported to increase the blocking field of a vertical SiC PCSS to 705 kV/cm when the entire sample region is irradiated with a 1×1018 cm-2 dose from a 1 MeV electron beam1. This paper investigates selectively irradiating specific regions of a SiC PCSS gap to characterize the effects on DC operation. Lateral switches were fabricated on a high-purity semi-insulating 4H-SiC sample and subsequently irradiated to form three sample types of differing irradiation regions. The selectively irradiated regions are: 1) mid-gap, 2) both contact-gap interfaces, and 3) a single gap-contact interface used for both anode and cathode testing configurations depending upon the polarity of the applied voltage.

IEEE Conferences

Simultaneous Measurement Of Nitrogen And Hydrogen Dissociation From Vacuum Ultraviolet Self-Absorption Spectroscopy In A Developing Low Temperature Plasma At Atmospheric Pressure

Authors: Laity, G; Fierro, A; Dickens, J; Neuber, A; Frank, K

PDF: https://aip.scitation.org/doi/10.1063/1.4804369

Abstract: We demonstrate a method for determining the dissociation density of N and H atoms present in a developing low temperature plasma, based on the emission and self-absorption of vacuum ultraviolet radiation produced from the plasma. Spark plasmas are produced via pulsed discharge in N-2/H-2 mixtures at atmospheric pressure, where information on the dissociated densities of the constituent gas molecules is desired without employing invasive diagnostic techniques. By analyzing the self-absorption line profile of 121.5 nm Lyman-alpha H radiation emitted within the first similar to 1.0 mm of plasma near the anode tip, a peak dissociated H atom concentration of 5.6 x 10(17) cm(-3) was observed similar to 100 ns into spark formation, with an estimated electron density of 2.65 x 10(18) cm(-3) determined from Stark broadening. Similarly, simultaneous line fitting of the N 120.0/124.3 nm emission profiles revealed a peak dissociated N atom concentration of 3.8 x 10(17) cm(-3) during the same discharge period. (C) 2013 AIP Publishing LLC.

Journal

Study of low-temperature plasma development utilizing a GPU-implemented 3D PIC/MCC simulation

Authors: Andrew S. Fierro; George R. Laity; Sterling R. Beeson; James C. Dickens; Andreas A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6634918

Abstract: Summary form only given. A GPU-accelerated 3-dimensional PIC/MCC simulation code was developed using the CUDA environment to study the physical processes involved in the development of a low-temperature plasma. The simulation results aid in quantifying transient plasma development as it is often inaccessible experimentally in detail even with modern noninvasive techniques such as non-linear laser spectroscopy or high-speed electrical diagnostics. Hence, computational methods, such as Particle-in-Cell (PIC) and Monte Carlo Collision (MCC), provide a complementary approach to determining the mechanisms leading to plasma development. However, fully modeling the physics of the plasma development is made difficult by the number of plasma processes that must be tracked simultaneously, and only recently have computing resources provided the capability to track tens of millions of particle interactions. Furthermore, the introduction of graphics processing unit (GPU) computing provides an attractive means for economical and efficient parallelization of scientific codes through a framework such as NVIDIA CUDA. As such, a GPU-accelerated 3-dimensional PIC/MCC simulation was developed using the CUDA environment to provide characteristics during the initial stage of plasma development in atmospheric pressure nitrogen. The simulation was run on a NVIDIA GTX 580 with 3 GB of memory and 512 CUDA cores. The simulated geometry consists of two paraboloid electrodes with a gap distance of 5 millimeters with Dirichlet boundary conditions, and 22 unique electron interactions with molecular nitrogen are considered. The electrodes are excited with a step voltage pulse of several thousand volts also assuming a uniformly distributed initial electron density of 104 cm-3 in the volume. For instance, results from a 5 nanosecond simulation reveal the development of positive ion space charge channels near the anode and cathode regions. These channels appear consistent with high-speed streamer photographs captured during plasma formation. The electron energy distribution function (EEDF) indicates a non-Maxwellian velocity distribution during the application of the high electric field. Furthermore, a typical electron density near the cathode is on the order of 7 × 108 cm-3. The results from numerical simulation will be compared in detail to experimentally accessible parameters such as electron temperature and dissociation degree.

Conferences

2012

An Explosively Driven High-Power Microwave Pulsed Power System

Authors: Elsayed, MA; Neuber, AA; Dickens, JC; Walter, JW; Kristiansen, M; Altgilbers, LL

PDF: https://aip.scitation.org/doi/10.1063/1.3681443

Abstract: The increased popularity of high power microwave systems and the various sources to drive them is the motivation behind the work to be presented. A stand-alone, self-contained explosively driven high power microwave pulsed power system has been designed, built, and tested at Texas Tech University's Center for Pulsed Power and Power Electronics. The system integrates four different sub-units that are composed of a battery driven prime power source utilizing capacitive energy storage, a dual stage helical flux compression generator as the main energy amplification device, an integrated power conditioning system with inductive energy storage including a fast opening electro-explosive switch, and a triode reflex geometry virtual cathode oscillator as the microwave radiating source. This system has displayed a measured electrical source power level of over 5 GW and peak radiated microwaves of about 200 MW. It is contained within a 15 cm diameter housing and measures 2 m in length, giving a housing volume of slightly less than 39 1. The system and its sub-components have been extensively studied, both as integrated and individual units, to further expand on components behavior and operation physics. This report will serve as a detailed design overview of each of the four subcomponents and provide detailed analysis of the overall system performance and benchmarks. (C) 2012 American Institute of Physics. [doi:10.1063/1.3681443]

Journal

Anode material outgassing at 250 A/cm2 current density under UHV conditions

Authors: J. M. Parson; J. C. Dickens; A. Neuber; J. Walter; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6383332

Abstract: Summary form only given. This presentation describes a study on gas evolution of plasma expansion in a reflex-triode virtual cathode oscillator (vircator) at ultra-high vacuum (UHV). Research has shown that explosive electron emission (EEE) processes at the cathode and ion / electron bombardment at the anode cause material erosion that produces regions of localized plasma. This plasma expansion has shown to lower gap impedance, cut off microwave performance and spoil low vacuum levels over time1. The goal of the study is to identify the gas species and their sources to better understand and limit the negative effects of plasma expansion in sealed tubes. The vacuum tube under investigation is a triode-geometry vircator with 20 cm2 cathode surface, driven by a 80 J Marx Generator with an approximate peak voltage and current, and pulse width of 200 kV and 5 kA, and 200 ns, respectively.

IEEE Conferences

Characterization Of Annealed Hpsi 4H-Sic For Photoconductive Semiconductor Switches

Authors: Hettler, C; Sullivan, WW; Dickens, J

PDF: https://www.scientific.net/MSF.717-720.301

Abstract: Annealing of high purity semi-insulating (HPSI) 4H-SiC is investigated as a method to improve bulk photoconductive semiconductor switches through recombination lifetime modification. Five samples of HPSI 4H-SiC were annealed at 1810 degrees C for lengths of time ranging from 3 to 300 minutes. The recombination lifetime of the unannealed and annealed samples was measured using a contactless microwave photoconductivity decay (MPCD) system. The MPCD system consists of a 35 GHz continuous microwave probe and a tripled Nd:YAG pulsed laser. The recombination lifetime was increased from 6 ns, as received, up to 185 ns by annealing for 300 minutes. To experimentally verify switch improvements, identical switches from unannealed and annealed material were fabricated and tested at low voltage. The unannealed device generated a 15 ns pulse with a 2 ns rise-time. The annealed device conducted for upwards of 300 ns with a comparable 2 ns rise-time. The increased recombination lifetime resulted in lower on-state resistance and increased energy transfer.

Conference Paper/Presentation

Charged Electret Deposition For The Manipulation Of High Power Microwave Flashover Delay Times

Authors: Stephens, J; Beeson, S; Dickens, J; Neuber, A

PDF: https://aip.scitation.org/doi/10.1063/1.4767649

Abstract: A quasi-permanent charged electret is embedded into the radiation window of a high power microwave system. It was experimentally observed that the additional electrostatic field introduced by the electret alters the delay times associated with the development of plasma at the window surface, resulting from high power microwave excitation. The magnitudes of both the statistical and formative delay times are investigated in detail for different pressures. Experimental observations are related to calculated discharge parameters using known E/p dependent properties. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4767649]

Journal

Comparison of CsI coated carbon velvet and aluminum cathodes operated at current density on the order of 300 A/cm2

Authors: C. Lynn; J. Walter; A. Neuber; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6518859

Abstract: Many high power microwave devices use explosive or flashover electron emission cathodes in order to generate the electron beam and thus drive the device. These diodes are simple to operate, requiring no heater or other external systems, and are capable of generating beam currents of several kA at accelerating voltages on the order of 100s of kV. However, they generally suffer from non-uniform emission, anode heating, out-gassing, and pulse shortening due to anode and cathode plasma expansion. The ability to rep-rate such a diode is generally limited by anode heating and out-gassing which are both affected by beam uniformity. Two diodes are compared in this work. One uses a machined aluminum cathode, which is made from solid aluminum with grooves milled onto the surface. The other diode utilizes a carbon velvet cathode which is CVD coated with CsI. Time integrated scintillator images of the electron beam at the anode were taken for both the carbon velvet and aluminum cathodes. Additionally, time resolved images of the emission centers were taken for the carbon velvet cathodes. Data sets of over 1000 shots were taken with each cathode and shot to shot variation in the peak “turn-on” electric field are compared. The lifetime of the aluminum cathode was exceeded before 1000 shots, whereas the carbon velvet cathode showed no degradation in operation.

IEEE Conferences

Experimentation and simulation of high current density surface coated electro-explosive fuses

Authors: J. C. Stephens; A. A. Neuber; J. C. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6518739

Abstract: The primary objective of the research discussed in this paper is to develop a compact electro-explosive fuse (EEF) for a flux compression generator (FCG) power conditioning system, capable of rapidly obtaining and maintaining high impedance. It was observed that significant gains in EEF performance are introduced with the application of an insulating coating to the surface of the EEF wire. A 2 kA small scale test bed has been designed to provide a single wire EEF with similar current density (~107 A/cm2), voltage gradient (~7 kV/cm), and timescale (~8 μs) as to what is seen by and EEF utilized in a HPM generating FCG system. With the small scale test bed EEF performance data was rapidly obtained at a significantly lower cost than equivalent full scale FCG experiments. A one-dimensional finite difference model coupled with the Los Alamos National Laboratory SESAME Equation-of-State database was utilized to simulate the resistive behavior of the single wire EEFs. Further, a large scale test bed, designed to provide a similar current action as to what is provided by a FCG is used to test 18 wire EEF arrays at the 40 kA level.

IEEE Conferences

Fiber optic system for high frequency burst operation of a silicon carbide photoconductive semiconductor switch

Authors: D. Mauch; C. Hettler; W. W. Sullivan; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6518752

Abstract: A fiber optic system was constructed to demonstrate high frequency operation of a silicon carbide (SiC) photoconductive semiconductor switch (PCSS). The goal was to transform a single high-energy laser pulse into a train of pulses by adding static delays into a multimode fiber bundle. The individual optical fibers comprising the fiber bundle incrementally add an additional amount of flight time to the light pulse. The end result is a train of pulses with a fixed delay between each pulse. A frequency-tripled Nd:YAG laser (10 ns FWHM) generating up to 300 mJ of light energy at 355 nm is coupled from free space into the optical fibers comprising the fiber light guide. Experimental results examining the collection and transmission efficiency, and the temporal output are presented.

IEEE Conferences

Frequency agility of a ferrite-loaded, nonlinear transmission line

Authors: Christopher Simmons; J.-W. Braxton Bragg; James Dickens; Andreas Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6518853

Abstract: A nonlinear transmission line (NLTL) provides a solidstate means of generating high power, microwave pulses. The NLTLs in this study are coaxial transmission lines whose center conductor is encapsulated by ferrite beads. Operational frequency can be controlled by varying the dimensions of the ferromagnetic material, which affects azimuthal magnetic fields and material losses, or by varying the biasing field strength. This research demonstrates frequency agility of an NLTL by documenting the design, construction, and testing of three NLTLs. The NLTL will be one meter long, and to test for frequency agility, three different sizes of ferrites will be loaded onto NLTL with various biasing fields applied. Azimuthal field strengths due to an incident high voltage pulse range from 10-36 kA/m with magnetic biasing fields between 0 kA/m and 50 kA/m.

Conferences

Gas Evolution Of Nickel, Stainless Steel 316 And Titanium Anodes In Vacuum Sealed Tubes

Authors: J. Parson; J. Dickens; J. Walter; A. Neuber; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6518724

Abstract: This paper presents a study on gas evolution of three different anode materials in vacuum sealed tubes under UHV conditions. The experimental apparatus consists of a high-power microwave (HPM) virtual-cathode oscillator (vircator) driven by a 200 ns, 80 J, 225 kV low-impedance Marx Generator. Plasma expansion due to explosive electron field emission has shown to lower gap impedance, spoil consistent low vacuum levels, and cut-off microwave radiation. The anode materials compared are nickel 201L (Ni201L), stainless steel 316L (SS316L) and grade-1 titanium (TiG1); with the cathode material being aluminum. The anodes were cleaned by the following method: rough polishing followed by electro-polishing, a ten minute microwave argon / 10% oxygen plasma cleaning process (ArO2) and finally, a 72 hour in situ bake-out at 300°C. Outgassing characteristics of each anode material are presented and compared.

Conference Paper/Presentation

Investigation Into the Temperature Dependence of Ferrimagnetic Nonlinear Transmission Lines

Authors: J. -. B. Bragg; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6148287

Abstract: In pulsed power systems, coaxial based nonlinear transmission lines (NLTLs) loaded with ferrimagnetic materials act as pulse sharpeners or high power microwave sources. Microwave generation comes by way of nonlinearities present in the ferrimagnetic material as well as excitation of damped gyromagnetic precession at large incident power levels. Ferrimagnetic properties highly depend on operating temperature; therefore, there exists a need to understand operational performance of ferrite loaded NLTLs under different temperature environments. Ferrite samples are chilled or heated to temperatures between -20°C to 150 °C, providing a wide range of possible operating temperatures. The Curie temperature of the tested samples is approximately 120 °C; therefore, this study allows observation of precession performance in possible operating temperatures as well as a brief look at the consequences of exceeding the Curie temperature. The design, testing, and results for an NLTL measuring 0.3 m in length with ferrite inner and outer diameters of 3 mm and 6 mm, respectively, are detailed. Results reveal precessional performance, both peak power and frequency of oscillations, versus temperature.

IEEE Journals

Investigation of vacuum UV absorption during low-temperature plasma formation in N2/H2 mixtures at atmospheric pressure

Authors: G. Laity; A. Neuber; A. Fierro; L. Hatfield; J. Dickens; K. Frank

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6518678

Abstract: This paper describes recent advances in the study of self-generated emission of vacuum ultraviolet (VUV) radiation which is produced during the early time period leading to high voltage breakdown at atmospheric pressure. Previous studies of air breakdown showed the presence of 121.5 nm radiation which is spontaneously emitted by excited hydrogen atoms, HI. Since this Lyman-α line is self-absorbed, it enabled inferring various plasma parameters from recording emission spectra from 115-135 nm for species of HI and NI. For instance, measurements in H2/N2 mixtures have revealed that the highest amount of absorption via HI atoms occurs in the high field region near the anode, implying that significant H2 dissociation for radiation-trapping is occurring in this zone. Selective spatial measurements further showed that the apparent VUV emission centers (i.e. streamer heads) move away from the anode and the mechanisms leading to line broadening (i.e. Stark effect from space charge) are a function of streamer position. The presented self-absorption mechanisms are essential in quantitatively understanding the role of VUV radiation transport via absorption for photo-ionization during streamer breakdown, in which re-absorption of high energy photons is inherently a requirement.

IEEE Conferences

Light Emission From CsI-Coated Carbon Velvet Cathodes Under Varied Conditions

Authors: Curtis F. Lynn; Andreas A. Neuber; John W. Walter; James C. Dickens; Magne Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6329448

Abstract: Many high-power electron devices utilize cold-cathode diodes to generate intense electron beams. These cold cathodes have the advantage of being capable of supplying several kiloamperes of current spread over a large cross section without the need for auxiliary components such as a heater supply. However, they suffer from many known problems such as nonuniform emission that can result in small areas of high current density on the anode and, thus, excessive anode heating. As a consequence, outgassing and vaporization of bulk material frequently leads to premature impedance collapse. Hence, minimizing nonuniform anode heating due to beam nonuniformity is paramount. As previously demonstrated, the use of a CsI-coated carbon velvet cathode improved beam uniformity, reduced outgassing, and mitigated early impedance collapse. To quantify the uniformity, temporal and spatially resolved images of the cathode plasma were taken for a CsI-coated carbon fiber cathode, operated at an average current density of ~150 A/cm2 under various conditions, i.e., without a field shaping ring, before and after discharge cleaning, and with a field shaping ring. All cathodes were operated in a sealed tube with a small integrated sputter ion pump to restore vacuum levels to 10-9 torr levels between subsequent shots.

Journals

Operation of a Sealed-Tube-Vircator High-Power-Microwave Source

Authors: John W. Walter; Curtis F. Lynn; James C. Dickens; Magne Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6179553

Abstract: The high-power-microwave (HPM) sources currently under development typically require constant pumping to maintain the high vacuum levels required for operation. This pumping is often done with either a cryo- or turbopumping system, either of which would be difficult to deploy in a compact portable system. A compact sealed-tube virtual cathode oscillator (vircator) source has been developed at Texas Tech University (TTU) that does not require a bulky external vacuum pump for operation. This device has a base vacuum pressure in the low range compared to the majority of laboratory HPM sources having vacuum levels in the - range. The reduced amount of trapped gasses in the sealed-tube ultrahigh-vacuum environment has the potential to greatly impact device performance. The TTU sealed-tube vircator is useful as a testbed for studying HPM source optimization under UHV conditions. Measured operational characteristics of the tube utilizing a carbon fiber cathode and a nickel anode are presented, along with radiated microwave measurements.

Journals

Performance And Optimization Of A 50 Kv Silicon Carbide Photoconductive Semiconductor Switch For Pulsed Power Applications

Authors: C. Hettler; W. W. Sullivan; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6518682

Abstract: A 50 kV silicon carbide photoconductive semiconductor switch (PCSS) is presented. The SiC PCSS device is fabricated from semi-insulating 4H-SiC in a newly-proposed rear-illuminated, radial switch structure. The improved structure reduces the peak electric field within the switch, extending the blocking voltage to over 50 kVdc. Electrostatic field simulations of the PCSS are presented along with experimental blocking curves. The PCSS demonstrated low on-state resistance, delivering over 27 MW of peak power into a 31 Ω load. Device modeling was performed to further optimize the switch for peak efficiency when illuminated with 355 nm light, a common laser wavelength. The switch structure was modified for peak operation at 355 nm and the experimental and theoretical results are compared.

Conference Paper/Presentation

Performance and Simulation Verification of a Mobile Solid State Pulsed Ring Down Array

Authors: D. V. Reale; J. Mankowksi; S. Holt; J. Walter; J. Dickens; N. R. Gonsalves

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6179550

Abstract: Mobile pulsed ring down arrays are of great interest due to their ability to deliver high peak power electromagnetic pulses. Global positioning system (GPS) devices are used as a means to provide position information to individual array elements. An array of solid state radiating structures was built and tested. The array test results are compared to a Monte Carlo array simulation that take into account source jitter, timing error, and distance error between array elements due to GPS measurements.

IEEE Journals

Serial arrangement of ferrimagnetic nonlinear transmission lines

Authors: J.-W. Braxton Bragg; Christopher Simmons; James C. Dickens; Andreas A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6518721

Abstract: Nonlinear transmission lines (NLTLs) utilizing ferrimagnetic materials for microwave generation have been realized as a possible solid-state replacement to traditional high power microwave (HPM) sources. The nonlinearities present in the material, along with interaction between pulsed, azimuthal magnetic fields and static, axial-biasing magnetic fields provide microwave (mesoband) generation with peak powers exceeding 30 MW at 2-4 GHz center frequency with 25 kV incident pulse magnitude. Additionally, an incident pulse of several nanoseconds is sharpened to hundreds of picoseconds. This study focuses on a serial arrangement of two NLTLs with 5 ns electrical length separation. Tests with 25 kV incident voltage are performed with varying bias schemes for each NLTL structure. The lines are terminated into a 50 Ω matched load. Measurements taken before and after each NLTL provide insight to the behavior of the traveling pulse. Results regarding peak power, frequency of operation, and system delay are discussed.

Conferences

Shallow Incorporation Of Nitrogen In Hpsi 4H-Sic Through The Laser Enhanced Diffusion Process

Authors: Sullivan, W; Hettler, C; Dickens, J

PDF: https://www.scientific.net/MSF.717-720.813

Abstract: This paper investigates n-type doping of point-defect compensated high purity semi-insulating (HPSI) 4H-SiC using a pulsed laser (10 ns FWHM @ 260 nm) for the introduction of nitrogen to shallow depths. A thermal model is presented using COMSOL Multiphysics featuring nonlinear temperature dependent material properties and a volumetric heat source term that takes into account the laser absorption depth for common ultraviolet irradiating wavelengths. The temperature distribution in the material and the amount of time that the surface and near-surface regions are at high temperature determines how many laser pulses are required to dope to the desired depth, and simulation results are presented and fit to measured data. The simulations and measured data show that for shallow doping a short wavelength ultraviolet laser should be used to localize the heat at the surface so the dopant can't diffuse deep into the material. The laser enhanced diffusion process has been used to incorporate nitrogen into HPSI 4H-SiC with a measured surface concentration greater than 10(20) cm(-3) and a nonlinear thermal model was built.

Conference Paper/Presentation

Spatially-resolved spectral observations of pulsed surface flashover in a nitrogen environment

Authors: Andrew Fierro; George Laity; Andreas Neuber; Lynn Hatfield; James Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6518677

Abstract: The development of streamers during the initial stage of a pulsed atmospheric discharge, which carries a high content of vacuum UV (VUV) emission, is investigated. Due to the high spectral absorptivity of atmospheric air in the VUV regime, few experiments have been conducted that observe the wavelength range shorter than 180 nm. However, direct photoionization is believed to play an important role in streamer formation during this phase of breakdown. VUV radiation (hν > 7 eV) is energetic enough to promote step-ionization and directly ionize background gas mixtures. Utilizing a VUV-sensitive experimental apparatus, spatially-resolved photomultiplier tube (PMT) measurements were recorded showing that initial VUV emission is dependent on the inhomogeneous field distribution near the electrodes. It was revealed that further into the developing streamer the position of instantaneous VUV emission is propagating from anode to cathode away from the initial VUV emissions. From these observations, the low temperature plasma is capable of producing high energy photons during the streamer phase as well as after voltage collapse.

Conferences

Stand-alone pulsed power generator for HPM generation

Authors: A. Neuber; J. Stephens; C. Lynn; J. Walter; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6383930

Abstract: Summary form only given. The challenges in developing and designing a 5 GW stand-alone pulsed power generator for driving a >; 100 MW high power microwave, HPM, source are discussed. Both, applied physics aspects of operating principles and limits of the individual sub-systems will be addressed. The energy, initially provided through a set of lithium-ion batteries internal to the generator, is boosted by an explosively driven flux compressor, FC, and inductively stored at a several kJ level. While the energy is stored on a microsecond timescale, it is, however, released into the load on a nanosecond timescale via an electro-explosive fuse, EEF, thus delivering GWs of electrical power to the HPM source for a duration of about 100 ns.

IEEE Conferences

Susceptibility of Electro-Explosive Devices to high pulsed electric fields

Authors: D. V. Reale; J. Mankowski; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6518716

Abstract: Commercially available Electro-Explosive Devices (EEDs), such as blasting caps, use electrical current to initiate a primary charge. Various detonators including bridge wire, match-type, exploding bridge wire, and slapper. The basic operating principle of the match-type device is to heat the ignition element to the ignition temperature of the primary explosive. The normal operation current profiles, both constant current and pulsed excitation, are well known, as is the ignition temperature. However, as safety and reliability are of great concern, both in the operation and storage of EEDs, the susceptibility of these devices to transient or spurious fields is of interest. The susceptibility of match-type EEDs to high pulsed electric fields is examined. A Finite Element Method (FEM) simulation is performed using COMSOL to determine the induced current in the bridgewire due to applied electric fields and the resulting Joule heating of the wire. Several situations are investigated including the EED in conductive and non-conductive media and leads open or terminated representing operational and storage conditions.

IEEE Conferences

The Effects Of Sub-Contact Nitrogen Doping On Silicon Carbide Photoconductive Semiconductor Switches

Authors: Sullivan, W; Hettler, C; Dickens, J

PDF: https://ieeexplore.ieee.org/document/6518684

Abstract: Forming non-rectifying (ohmic) contacts to wide band gap semiconductors such as silicon carbide (SiC) requires a heavily doped subsurface layer to reduce the Schottky barrier height and allow efficient electron injection. Nitrogen, a common n-type dopant in SiC, was incorporated into a SiC sample using a laser enhanced diffusion process in which an impurity is incorporated into the semiconductor to very high surface concentrations (> 10(20) cm(-3)) and very shallow depths (< 200 nm) with the use of a pulsed 266 nm laser. This paper evaluates the effects of nitrogen introduced through laser enhanced diffusion on the contact formation and the efficiency of silicon carbide photoconductive switches at low and high injection levels under different biasing conditions. Nine lateral switches were fabricated on a high-purity semi-insulating 4H-SiC sample; three with no sub-contact doping, three with sub-contact doping on only one contact, and three with sub-contact doping on both contacts. Results are presented for tests under pulsed laser illumination with sub-contact doping on only the anode, only the cathode, neither, and on both of the contacts.

Conference Paper/Presentation

2011

A mobile Pulsed Ring Down source array using low power solid state radiators

Authors: D. Reale; J. Mankowski; S. Holt; J. Walter; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6191489

Abstract: Current work at Texas Tech University is focused on enabling technologies for a mobile Pulsed Ring Down Array. A Monte Carlo Simulation was developed to evaluate the potential performance of an array using current capabilities and to determine the future requirements to achieve the desired system performance. Error sources included are the position error of each element, the jitter of the closing switch, and the synchronization error between elements. Error distributions for the simulation are based on device testing. The array is tested by adding an artificial delay that represents an error source. The simulation is verified by running each error source independently and comparing the results to the experimental data. A system of low power radiators based on stacked MOSFET switches were built to simulate the Pulsed Ring Down Source (PRDS) elements for testing purposes. The testing methodology and results are presented.

IEEE Conferences

Advanced imaging of pulsed atmospheric surface flashover

Authors: A. Fierro; G. Laity; L. Hatfield; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6191414

Abstract: Vacuum Ultraviolet (VUV) radiation is commonly thought to enhance streamer formation, as it is energetic enough to cause photoionization in the gaseous volume. Light with wavelengths below 180 nm, i.e. VUV, is highly absorbed in the atmosphere which increases the difficulty of measuring any VUV emission from gaseous breakdown at atmospheric pressure. Nevertheless, VUV emission from pulsed surface flashover at atmospheric conditions was previously recorded at Texas Tech. A second generation system was designed to image VUV and visible emission directly while also preserving the spatial profile. The visible emission is imaged through an air-side focused ICCD, while VUV emission is imaged through a vacuum spectrograph. The variable length gap was excited with a pulser designed for a 100 ns rise time and 50 kV peak output. Captured images of visible light emission from streamers produced in oxygen are diffuse whereas nitrogen produces streamers that are segmented. VUV spatial images taken in oxygen reveal stronger emission closer to the cathode region, while nitrogen produces a more distributed intensity profile across the gap. While MgF2 enabled transmission and measurement of VUV, streamer characteristics recorded in the visible light spectrum of surface flashover on BK7 dielectric windows were also investigated. In this paper, the observed streamer images in both visible and VUV wavelength range will be discussed as it relates to surface flashover at atmospheric pressure.

IEEE Conferences

An “energy efficient” vircator-based HPM system

Authors: J. Walterx; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6191558

Abstract: A common figure of merit utilized for HPM sources is the instantaneous power efficiency at the time of peak output power. This conversion efficiency from the electron beam power to radiated microwave power disregards the overall energy efficiency of the system, which is vitally important in systems intended for practical application. Optimizing the overall system energy efficiency allows a reduction in volume, weight, and prime power requirements that makes for a much more practical and fieldable system. Texas Tech University has developed a vircator-based laboratory HPM system that has a high end-to-end energy efficiency relative to other HPM systems. The system utilizes a sealed-tube vircator source that requires no external vacuum pumping subsystem. For rep-rate use, the tube contains an integrated low-power sputter ion pump. The lack of need for an externally applied magnetic field saves complexity, weight, and potentially power. The vircator tube is simple and robust. The source is driven by a Marx generator utilizing pulse forming networks (PFNs) instead of lumped capacitors. Utilizing PFNs allows the driver to apply a more ideal pulse shape to the source than a traditional Marx, enhancing the performance of the source and reducing the amount of energy wasted in the rise and fall of the pulse. The system has demonstrated greater than 1% energy efficiency from the energy stored in the Marx to the radiated HPM, with potential for improvement. The peak total radiated output power of the system is between 50 and 100 MW.

IEEE Conferences

COMSED 2 - recent advances to an explosively driven high power microwave Pulsed Power system

Authors: Mohamed A. Elsayed; Andreas A. Neuber; John W. Walter; Andrew J. Young; Charlie S. Anderson; Shad L. Holt; James Dickens; Magne Kristiansen; Larry L. Altgilbers

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6191480

Abstract: Continued efforts at the Center for Pulsed Power and Power Electronics at Texas Tech University have led to improvements to the design, testing, and performance of a high power microwave (HPM) system, which is sourced by Lithium-ion Polymer batteries, a polypropylene capacitor, and high energetics. An indirectly seeded two-stage helical flux compression generator (HFCG) produces electrical energies in the kilo-Joule regime into a low impedance inductive load, varying from 2 μH to 3 μH. This high current output of the explosively driven generator is conditioned with a pure silver-wire-based electro-explosive opening switch, which reaches voltage levels in excess of 300 kV into a 18 Ohm load. Upon reaching levels high enough to close an integrated peaking switch, this high voltage is sufficient to drive a reflex triode virtual cathode oscillator, also known as a Vircator, into radiation. The Vircator employed in the system has reached microwave radiation levels well over 100 Megawatts from a cavity volume of less than 5 Liters at a microwave frequency of a few GHz. The complete system is governed through a microcontroller that regulates seed and detonator charging levels as well as discharge times using built-in feedback diagnostics. The complete system aforementioned is constrained to 15 centimeter diameter and measures 183 centimeter in length with an overall volume of less than 34 Liters. No external power or vacuum pumping for the HPM tube is required. This report will discuss recent design advancements and improvements on the HPM system and its sub-components that include the compact seed source, HFCG, and the power conditioning system. Improved safety features implemented as well as novel diagnostic integration will be discussed as well.

Conferences

Compact electro-explosive fuse optimization for a helical flux compression generator

Authors: J. C. Stephens; A. A. Neuber; J. C. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6191477

Abstract: This paper presents the optimization of a compact electro-explosive fuse designed for the power conditioning system to be driven by a helical flux compression generator (HFCG). An electro-explosive fuse interrupts the current flow from the HFCG through a storage inductor on a 50 to 100 ns timescale inducing a voltage large enough to close a peaking gap, which commutates the energy in the storage inductor into a 20 Ohm load at voltage levels above 200 kV. Experimental data has revealed that electro-explosive fuses with wires in closer proximity to one another have consistently produced lower pulsed voltages than fuses with larger wire spacings. This paper addresses possible factors that might contribute to this drop in performance. An electro-magnetic field solver is used to model the current redistribution in the fuse wires. The experimentally observed performance of compact fuses with varying wire spacings is presented.

IEEE Conferences

Design and Evaluation of a Compact Silicon Carbide Photoconductive Semiconductor Switch

Authors: C. James; C. Hettler; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5643138

Abstract: A high-power vertical photoconductive switch was fabricated from a high-purity semi-insulating 4H-SiC wafer. The device was fabricated from an as-grown wafer with resistivity >; 109 Ω · cm and had a dark resistance of greater than 6 × 109 Ω. The switch was operated at 15 kV/cm and achieved a peak photocurrent of 14 A into a 25-Ω load. Optimization of the excitation wavelength and switch geometry using an optical parametric oscillator was studied in order to decrease the laser requirements for optical triggering. This has led to a decrease in ON-state resistance of almost two orders of magnitude for similar excitation energy levels at visible wavelengths. This work forms the basis for developing very compact high-voltage photoconductive switches.

IEEE Journals

Design of an apparatus for optical and VUV spectroscopy of explosive emission processes

Authors: J. Parsony; J. Dickens; A. Neuber; J. Walter; J. Krile; J. Vara

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6191565

Abstract: This study focuses on the design of an experimental apparatus for optical and vacuum ultraviolet (VUV) spectroscopy of explosive emission processes at the cathode in a high power vacuum sealed tube. The system consists of a high power pulsed Nd:YAG laser with a highly tunable optical parametric oscillator (OPO, 200 to 2600 nm), a 300 kV, 80 J Marx Generator, and a triode-geometry vircator that is 6 inches in diameter and 11 inches in length. It has been observed that the explosive emission occurring at the cathode forms a plasma front propagating across the A-K gap negatively affecting the impedance of the gap thus shortening pulse length and spoiling the desired consistent low vacuum within the sealed tube. The scope of this project is to probe the plasma formed between the A-K gap to determine the species emitted off the cathode. The timing integration of each sub-system is very critical as the window for measurement is approximately 200 ns. A compact, fiber optically coupled, battery-operated, low jitter (500 ps), fast risetime (20 ns) pulse trigger generator has been designed and incorporated as the trigger source in a trigatron triggering scheme for the Marx generator. Preliminary jitter measurements of 20 to 30 ns have been seen on the fully erected Marx Generator. The intent of this paper is to discuss the details of the various sub-systems and the timing between them, enabling optical / VUV spectroscopic measurements of the explosive emission process.

IEEE Conferences

Evaluation of a triggered 50 kV, 100 Hz, sub-ns jitter high pressure gas switch with pressure, trigger magnitude and gas temperature

Authors: Y. Chen; J. Dickens; J. Mankowski; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5976084

Abstract: Research efforts at Texas Tech University on impulse antenna phased array has resulted in the development of a dependable high voltage, high repetition rate switch that can minimize jitter into the ps range. To accurately synchronize a phased array to steer and preserve the risetime of a radiated pulse, the jitter can only be a fraction of this risetime. Initial testing with a similar system in produced sub-ns jitter results for operations in different gases and gas mixtures. This paper discusses in detail 50 kV, 100 Hz switch operations using different testing parameters. The switch jitter as a function of triggering conditions is discussed, including a comprehensive evaluation of jitter as a function of operation pressure as well as trigger magnitude. Several phenomenon were observed and discussed to quantify the switch jitter with respect to operation pressure and trigger magnitude. The temperature of gas and its effects on switch jitter is also documented in this paper, with a jitter improvement of ~25% recorded. An empirical formula was determined as a function of the gas density, electric field of the main gap, and electric field for the trigger for the experiments conducted in this manuscript. A 50 Ω, 1 nF pulse forming line is charged to 50 kV and provides the low inductance voltage source to test the switch. The hermetically sealed spark gap, with a modular design composed of copper tungsten electrodes, gas feeds, Kel-F lining, as a well as a G-10 shell is used to house the high pressure gases for the experiments. Trigatron-type triggering is provided by a solid state opening switch voltage source that supplies 75-150 kV, 10 ns risetime pulses at a rep rate up to 100 Hz in burst mode.

IEEE Journals

Initial anode optimization for a compact sealed tube vircator

Authors: J. Walter; J. Vara; C. Lynn; J. Dickens; A. Neuber; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6191517

Abstract: During the development and optimization of a compact sealed tube virtual cathode oscillator (vircator) at Texas Tech University, it has become apparent that processes at the anode have a significant impact on tube performance. The impact of the high energy, high current density (100-200 A/cm2 or higher) beam on the anode will cause outgassing, plasma production, and anode melting and material ejection. The emitted material expands, eventually impacting the anode transparency and (combined with the plasma formed at the cathode) shorting out the anode-cathode gap. This expansion limits the maximum radiated pulse width, and can also limit the peak output power. The residual evolved gas also negatively impacts the maximum repetition rate of the tube. An effort is underway to study the thermal behavior, gases evolved, and transparency versus time for different vircator anode materials and material treatments. Several different anode materials are under investigation, including stainless steel, copper tungsten, tantalum, nickel, and molybdenum. The effect of different treatments on the anodes before tube assembly is also being studied. The gases that are evolved during operation have been characterized utilizing pressure and residual gas analyzer measurements. The pre-shot background pressure in the tube is in the ultra-high vacuum range (10-8 to 10-9 Torr), and the vircator is not pumped on during firing. The data collected for the different materials is presented.

IEEE Conferences

Laser enhanced diffusion of nitrogen in high purity semi-insulating 4H silicon carbide substrates for non-rectifying contact formation to photoconductive semiconductor switches

Authors: W. Sullivan; C. Hettler; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6191650

Abstract: Non-rectifying (ohmic) contacts are essential for efficient photoconductive semiconductor switch performance and maximizing breakdown voltage. Fabricating ohmic contacts requires a very heavily doped surface layer (>; 1018 cm-3), and in silicon carbide (SiC) is typically done by ion implantation. The high energy ions from this process often cause surface and bulk damage, and a high temperature anneal is required to repair the crystal structure and activate the impurities. This paper investigates the use of a gas immersion laser enhanced diffusion system to selectively dope the SiC as an attractive, low cost alternative to ion implantation. A pulsed 260 nm laser with a peak irradiance of 69.9 MW/cm2 was used to dope a high purity semi-insulating (HPSI) 4H-SiC sample with nitrogen to a depth of 150 nm, with measured a surface concentration greater than 1020 cm-3. Using a one dimensional thermal model, the experimental data was fit to diffusion coefficients that are orders of magnitude greater than typically seen in SiC. The gas immersion laser doping technique has been demonstrated as a viable alternative to ion implantation for selective area doping of SiC bulk photoconductive switches.

IEEE Conferences

Nanosecond-scale spectroscopy of vacuum ultraviolet emission from pulsed atmospheric discharges

Authors: G. Laity; A. Neuber; A. Fierro; J. Dickens; L. Hatfield

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6191416

Abstract: This paper describes a 2nd-generation system for directly studying the emission of vacuum ultraviolet (VUV) light from pulsed dielectric surface flashover at atmospheric pressure. The role of self-produced VUV emission (i.e. energies greater than 7 eV) on photo-ionization processes during the early nanoseconds of pulsed discharges is virtually unexplored, and yet could be a significant factor in the physics of fast breakdown of directed energy systems (such as MW-class high power microwave devices) in the aerospace community. First generation experiments at Texas Tech University have shown that VUV emission corresponding to nitrogen and oxygen excitation in the energy range 8-10 eV is easily produced, but the use of MgF2 optics inhibited future work with existing hardware due to the transmission cutoff of this dielectric material and chromatic aberration if used as a lensing medium. In an effort to enhance the detection capabilities of our hardware in the wavelength range from 115-135 nm, the current system utilizes a custom designed set of off-axis parabolic MgF2-Aluminium coated mirrors as the primary focusing element. High resolution spectroscopy with the upgraded system resulted in the observation of the nitrogen doublet at 149.5 nm, leading to a better fit for the appropriate line broadening parameters for an approximate 10 eV Boltzmann electronic temperature. Evidence of self-absorption for HI (121.5 nm) provides new insight into the generation of space charge in these plasma structures, which has been investigated quantitatively in both SF6-H2 and N2-H2 mixtures.

IEEE Conferences

Phased array pulsed ring-down source synchronization with a GPS based timing system

Authors: Y. Chen; D. Reale; J. Dickens; S. Holt; J. Mankowski; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5976097

Abstract: A collaborative effort at Texas Tech University on high power RF transmitters has directly translated to the development of phased array pulsed ring down sources (PRDS). By operating an array of PRDS, peak radiating power on target can theoretically be increased to the squared of N sources. The primary limitation on the application of the array concept is the jitter with which the individual sources can be fired. An ideal jitter of a small fraction of the risetime is required to accurately synchronize the array to steer and preserve the amplitude of the radiated pulse. This paper describes in detail the implementation of a GPS based timing system that will synchronize the operation of each of the elements of a geospatially distributed phased array to maximize the peak power delivered to a single position. Theoretical array performance is shown through Monte Carlo simulations, accounting for switch jitter and a range of GPS timing jitter. Each module will include a control unit, low jitter pulser, low jitter spark gap, antenna element, as well as a GPS receiver. The location of each module is transmitted to a central controller, which calculates and dictates when each element is fired. Low jitter in the timing of the GPS reference signal is essential in synchronizing each element to deliver the maximum power. Testing using a preliminary setup using GPS technology is conducted with both 1 pps and 100 pps outputs. Jitter results between modules are recorded to ~10 ns without any correction factors and 1-2 ns with simple averaging. With the timing and geospatial errors taken into account, the proposed concept will show usable gains at phased array operating frequencies up to several hundred MHz.

IEEE Journals

Phenomenology of streamer propagation during pulsed dielectric surface flashover

Authors: G. Laity; A. Neuber; A. Fierro; J. Dickens; L. Hatfield

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5976080

Abstract: There is a growing demand for understanding the physics of surface flashover, as it relates to the breakdown of electric fields on high power systems in the aerospace community. Specifically, the quantitative role of vacuum ultraviolet (VUV) radiation which is self-produced during the initial nanoseconds of surface flashover is virtually unknown. An experiment was constructed which allows detailed electrical and optical measurements of VUV emission during the timescales in which streamers are propagating before the transition into spark discharge. Repeated surface flashover events are generated using a solid-state high voltage pulser, with breakdown recorded in a number of gases at atmospheric pressure. Streamers are photographed using fast optical imaging with 3 ns resolution. Fast voltage and current diagnostics revealed a number of distinct stages of streamer development ranging from the onset of cathode directed streamers to the sharp current rise during final voltage collapse. The emission of VUV radiation is discussed in context to the observed streamer and electrical characteristics.

IEEE Journals

Physics investigations of vacuum ultraviolet emission from pulsed atmospheric discharges

Authors: G. Laity; A. Fierro; A. Neuber; L. Hatfield; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5993029

Abstract: Summary form only given. The role of self-produced VUV emission (i.e. energies greater than 7 eV) on photo-ionization processes during the early nanoseconds of pulsed discharges is a new area of interest in the aerospace community, and could play a significant role in the theoretical understanding of plasma generation at short (nanosecond) timescales. Our previously reported experiments have shown VUV emission from atomic species of oxygen and nitrogen, which were excited during breakdown, but detailed analysis of emission in the range 115 - 135 nm was difficult due to chromatic aberration of VUV transparent optics in this regime. These limitations were recently alleviated by fitting the spectral apparatus with a custom set of MgF2-Aluminum coated off-axis parabolic mirrors used in conjunction with a high resolution vacuum monochromator. VUV emission is observed by either VUV sensitive intensified CCD or photomultiplier sensors, with additional current/voltage monitors and externally focused fast-frame (nanosecond capable) imaging complimenting the diagnostic setup. High resolution spectroscopy has been achieved in the excitation range of interest (8 - 10 eV), where species of atmospheric gases and electrode metal have been identified during the early nanoseconds of plasma generation. Temporal studies have shown that most VUV emission occurs during the time before voltage collapse and subsequent power flow, while the majority of visible emission is released after breakdown when the electron energy distribution has shifted to lower energies. This experiment also allowed for direct emission imaging of VUV radiation, where the spatial profile relative to plasma position is still intact. While the observed metal species are only emitted in the regions close to the electrodes as expected, significant differences were observed for species of NI (which is released throughout the plasma volume) and OI (which is released strongly in regions of high electric field) atoms during breakdown. This is most likely due to the accumulation of ionic space charge from photo-ionization in the gas volume, coupled with the high absorption cross section of molecular oxygen in the VUV range. These measurements will be discussed in context to current physics models of electric breakdown and plasma generation at atmospheric pressure.

IEEE Conferences

Recombination lifetime modification in bulk, semi-insulating 4H-SiC photoconductive switches

Authors: C. Hettler; W. Sullivan; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6191652

Abstract: A series of high temperature annealing experiments were performed to characterize the processing parameters that alter the recombination lifetime in high purity, semi-insulating (HPSI) silicon carbide (SiC). All annealed samples were diced from a single 4H-SiC wafer with a measured resistivity of greater than 109 Ω-cm. The samples were annealed for various lengths of time in a PID-controlled high temperature induction furnace at 1810 °C. A 35 GHz microwave photoconductivity decay (MPCD) system was used to measure the transient photoconductivity of the as-grown and processed samples. Through numerical processing of the temporal characteristics of the illuminating laser pulse, the photoconductivity transients were simulated with various recombination lifetimes to fit the experimental MPCD data. The results show that the as-grown material has an average recombination lifetime of 6 ns. However, samples annealed for more than 100 minutes demonstrated recombination lifetimes in excess of 100 ns. The annealing process reduces the concentration of shallow point defects (Z1/Z2) in the bulk material which serve as recombination centers in HPSI 4H-SiC, extending the carrier lifetime. Finally, the impacts of increased recombination lifetime in photoconductive switch operation and performance are presented and discussed.

IEEE Conferences

Spatially Resolved VUV Spectral Imaging of Pulsed Atmospheric Flashover

Authors: G. R. Laity; A. S. Fierro; L. L. Hatfield; J. C. Dickens; A. A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5776698

Abstract: The quantitative role of self-produced vacuum-ultraviolet (VUV) light on photoionization-dominated gas discharges is currently an area of interest in the aerospace community. In this paper, we present the images of the VUV spectroscopic analysis of a pulsed atmospheric flashover, where the spatial content of emission relative to electrode geometry has been preserved. The observed spatial profile of emission is dependent on radiating species in the range of 120-125 nm and is discussed in relation to the physics of nanosecond discharges.

IEEE Journals

Temperature dependence of ferrimagnetic based nonlinear transmission line

Authors: J. -. Braggy; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6191411

Abstract: Ferrite loaded nonlinear transmission lines (NLTLs) are able to act as high power microwave sources, utilizing the nonlinearities present in ferrimagnetic materials and the excitation of damped gyromagnetic precession at high incident power levels. Ferrimagnetic properties depend greatly on operating temperatures; therefore, there exists a need to know the ideal temperature at which to operate ferrite loaded NLTLs. Ferrites are chilled or heated to a certain temperature for a time suitable to allow internal ferrite temperature uniformity. Experimental temperatures ranged from approximately -20 °C up to 150 °C, which is slightly above the Curie temperature of the loaded ferrites. This temperature range allows observation of precession dependence on temperature while maintaining ferrimagnetic properties and a single look at the behavior outside the ferrimagnetic regime. Above the Curie temperature the loaded ferrites become paramagnetic and lose ferrimagnetic properties. The design, testing, and results are detailed for an NLTL measuring 0.3 m length and ferrite inner and outer diameters of 3 mm and 6 mm respectively. Figures comparing output waveforms at different temperatures, output power versus temperature, and output frequency versus temperature are shown.

IEEE Conferences

Testing of a low inductance stacked mosfet switch for Pulsed Ring Down Sources

Authors: D. Realey; J. Mankowski; S. Holt; J. Walter; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6191656

Abstract: An inexpensive and mobile array of Pulsed Ring Down Sources (PRDS) were required to verify previous simulation results. Initial attempts to use a stacked MosFET circuit as a closing switch were unsuccessful due to the additional series inductance of the MosFET stack lowering the frequency of the oscillation on the coaxial radiator. Experimental results showed that by reducing the parasitic inductance due to the geometry of the MosFET stack, the frequency of the oscillation could be increased. Increased series resistance due to the stacked MosFETs was also a concern. In order to minimize the parasitic inductance of the stack and allow for multiple stacks to be connected in parallel, a printed circuit board was designed. Results from testing of the original switch stacks and board assembly are presented and compared with PSPICE simulations. Using the simulation results, the reduction in parasitic inductance can be estimated.

IEEE Conferences

Theoretical performance of a mobile GPS linked pulsed ring down array

Authors: D. Reale; J. Mankowski; Y. Chen; J. Walter; S. Holt; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=5976098

Abstract: The development of mobile Pulsed Ring Down Source (PRDS) arrays requires the ability to accurately determine the relative positions of array elements at distances, and in situations, where discrete measurements are not practical. At the frequencies of interest, centimeter level accuracy is required for the array to localize radiated energy at a given target location. Global Positioning System (GPS) devices and techniques are evaluated for the purpose of position acquisition. Previously a Monte Carlo simulation was developed that takes into account the position error, the GPS timing error, and the switch jitter of the element. The error sources are combined and used a metric to evaluate and predict the array performance. Results of the GPS device testing, as well as previous work, are used as the input parameters of the simulation to determine their viability for use in the implementation of PRDS arrays capable of radiating at frequencies of up to 500 MHz.

Journals

2010

Atmospheric flashover in a symmetric electric field geometry

Authors: G. Rogers; A. Neuber; L. Hatfield; G. Laity; K. Frank; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5958293

Abstract: In an attempt to identify the mechanisms leading to pulsed dielectric surface flashover in atmospheric conditions, surface flashover across a magnesium fluoride (MgF2) window was studied. The electrode configuration and the applied pulsed voltage level were chosen such that the generated electric field was symmetric with respect to the centerline between the electrodes. That is, neither electrode was favored with respect to flashover/breakdown initiation. A semiconductor-switched 32 kV pulse with 140 ns rise time was applied to the 8 mm wide flashover gap in air, nitrogen, and oxygen at atmospheric pressure. Fast voltage and current measurements along with nanosecond imaging revealed four stages of flashover development: (1) Onset of a cathode directed streamer with a charge on the order of 100 pC and traveling with a speed of ~1 mm/ns at a macroscopic field level of ~10 kV/cm associated with a slow current rise (on the order of 10-3 A/ns) temporarily augmented by (2) a 5 ns wide current spike at the moment when the streamer reaches the cathode followed by (3) a cathode directed streamer focused toward the center of the flashover gap with a slow rising current leading to (4) a sharp current rise (on the order of 10 A/ns) reaching roughly a circuit limited 45 A about 20 ns after the return strike meets an anode directed streamer. Although present in all tested gases, the current spike at the end of stage (2) is most different for all three gases and having the greatest impact in air.

IEEE Conferences

COMSED 1 — A compact, gigawatt class microwave source utilizing helical flux compression generator based pulsed power

Authors: A. Young; A. Neuber; M. Elsayed; J. Korn; J. Walter; S. Holt; J. Dickens; M. Kristiansen; L. L. Altgilbers

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5958309

Abstract: Recent progress in the development of a compact, portable, explosively-driven high power microwave source is presented. The envelope to which the system must fit has a 15 cm diameter, which means each sub-system fits within this dimension, with an optimized overall length. The system includes an autonomous prime energy source, which provides the initial energy for a two-stage, flux-trapping helical flux compression generator (FCG). Typical output from the FCG is several kilojoules into a 3 μH inductor. The amplified energy from the generator, after pulse conditioning, is used to drive a virtual cathode oscillator (vircator). Recorded voltages at the vircator with this arrangement were greater than 200 kV in experiments, where radiated output powers of greater than 100 MW have been measured. Voltages of at least 300 kV, with an electrical output power of 4 GW or greater, were generated by the FCG driven pulsed power source into a water resistor load with an impedance similar to the operating impedance of the vircator. A description of each component of the compact microwave source will be given, along with waveforms from tests performed with the components independent of the rest of the system. Data from experiments with the fully integrated microwave system will be shown, and analysis will be offered to detail the performance of the system in its present state.

IEEE Conferences

Carrier lifetime studies of semi-insulating silicon carbide for photoconductive switch applications

Authors: C. Hettler; C. James; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5958289

Abstract: A contactless microwave photoconductivity decay (MPCD) method has been used to measure recombination lifetime and relative conductivity of semi-insulating (SI) silicon carbide (SiC) wafers. A pulsed laser, tunable from 210 nm to 2 μm, has been used to probe above and below band gap photoconductive responses of four SI SiC wafers. The carrier lifetimes were calculated by comparing the reflected microwave signal to the photo response of a fast (<; 300 ps) photodiode. Three vanadium-doped 6H-SiC wafers, with bulk resistivities ranging from 105 Ω-cm to 1011 Ω-cm, and one high purity semi-insulating (HPSI) 4H-SiC wafer (>; 109 Ω-cm) were studied. The photoconductive response of each wafer set is presented. The HPSI wafer demonstrated longer carrier lifetime and improved above band gap photoconductivity compared to the vanadium-doped wafers. The difference in carrier lifetimes are attributed to higher densities of recombination centers (vanadium acceptors) in the 6H-SiC substrates.

IEEE Conferences

Effects of gas temperature and gas mixtures on a triggered, sub-ns jitter, 50 kV, 100 Hz spark gap

Authors: Y. Chen; J. Dickens; J. Mankowski; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5958315

Abstract: Recent research efforts at Texas Tech University on impulse antenna phased array have shown that an ideal jitter of a small fraction of the rise-time is required to accurately synchronize the array to steer and preserve the rise-time of the radiated pulse. This has necessitated the need to develop a reliable high voltage, high repetition rate switch that will operate with very low jitter. This manuscript presents the impact gases and gas mixtures have on switch performance which includes recovery rate and in particular jitter. A 50 Ω, 1 nF pulse forming line is charged to 50 kV and provides the low inductance voltage source to test the different gases. Gases tested include N2, dry air, H2, and SF6, as well as N2-H2, N2-SF6, N2-Ar, and gas mixtures containing Kr85. This manuscript will discuss in detail 50 kV, 100 Hz triggered switch operations of such gases. Switch jitter as a result of triggering conditions is also discussed, also including an evaluation of jitter as a function of formative delay in various gases. An evaluation of switch jitter as a function of operation time and gas temperature is also included. Triggering is provided by a solid state opening switch voltage source that supplies ~150 kV, 10 ns rise-time pulses at a rep-rate up to 100 Hz in burst mode. A hermetically sealed spark gap with a Kel-F -PCTFE (PolyCholoroTriFluoroEthylene) lining is used to house the switch and high pressure gas. It is shown that jitter is strongly dependent on the triggering technique, as well as the trigger magnitude, with ionization rates playing an important role. Sub-ns jitter is seen with a variety of gases and gas mixtures with H2 producing the best results. Varying the gas temperature and addition of radioactive sources are seen to improve the switch jitter.

IEEE Conferences

Gas evolution measurements in a sealed vircator tube

Authors: J. Vara; J. Walter; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5958432

Abstract: The gases evolved during operation of high power microwave devices, such as virtual cathode oscillators (vircators), can be detrimental to their power output, output pulse width, and maximum pulse repetition rate. Gases are evolved both from processes at the cathode (such as explosive electron emission) and at the anode (due to heating from the electron beam). In this project, a residual gas analyzer and pressure measurements have been utilized to characterize the gases generated during operation of a sealed vircator tube. The background pressure in the tube before firing is in the ultra-high vacuum range (~10-8 Torr). The vircator is not pumped on during firing. After firing, the measurements are made, and then the tube is ion pumped back down to the background pressure before the next shot. Multiple anode and cathode materials will be tested, with measurements made of both the quantity and types of gases evolved during firing. Example test materials include stainless steel, OFHC copper, copper tungsten, and tantalum. For all tests, the vircator is driven directly from a low impedance Marx generator, with no intermediate pulse forming. The system design and diagnostic systems are described, and gas quantity and composition data is presented.

IEEE Conferences

High-purity semi-insulating 4H-SiC as a high-voltage switch material

Authors: C. James; C. Hettler; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5958348

Abstract: A photoconductive semiconductor switch (PCSS) fabricated from high-purity semi-insulating (HPSI) 4H-SiC is presented. This switch shows improvement over similar designs based on 6H-SiC due to higher carrier mobility and longer carrier lifetimes. Using a novel micropipe identification method, vertical PCSS devices have been fabricated from c-plane wafers that lead to higher hold-off voltage and decreased on-state resistance as compared to a lateral geometry. Operation of the photo switch in both on- and off-state is demonstrated and material characterization via microwave photoconductance decay (MPCD) is given.

IEEE Conferences

Magnetic biasing of ferrite filled nonlinear transmission lines

Authors: J. Bragg; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5958430

Abstract: Ferrite filled coaxial lines have been shown to sharpen input pulses due to their nonlinear magnetic properties. This effect can be amplified by applying an axial magnetic biasing field. In addition to a steeper leading edge, oscillations in the microwave bands have been observed. These oscillations arise from damped gyromagnetic precession occurring in the ferrite. The magnetic bias necessary to generate damped oscillations and steepened pulse sharpening effects is produced by two separate means; a current carrying solenoid or, the less investigated case, permanent magnets. Multiple NLTLs are tested at lengths of 0.3 meters and 1 meter with an outer diameter of 13 mm. Permanent magnets with varying strengths were placed in different locations for multiple tests. Experiments and setups for these designs are detailed and their results are discussed.

IEEE Conferences

Optimizing wire parameters in exploding wire arrays

Authors: C. Davis; A. Neuber; J. Stephens; A. Young; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5958416

Abstract: Exploding wire arrays as fast switches are of interest for explosive pulsed power applications utilizing magnetic flux compression. This type of opening switch has proven effective in producing pulses of several hundred kilovolts into vacuum diode loads. The research presented here discusses an exploding wire array capable of producing single digit kilo-joules, 100 nanosecond pulses when driven by a 45 kilo-Amp current with a waveform closely resembling typical magnetic flux compression output. For this specific parameter range, the optimal fuse design was developed based on the experimental behavior of the fuse under variation of parameters such as wire spacing, shielding, and quenching medium. Each fuse is composed of several silver wires arranged in a straight wire cylindrical array and is typically pressurized in a chamber filled with about 0.6 MPa of SF6. The tradeoff between wire spacing and voltage output was addressed by designing four different fuse termination pairs each with a diameter that increased wire spacing from 5 to 20 mm in 5 mm increments. A wire shield test was also conducted as an extension to the wire spacing experiment to uncover any mutual radiative effects between wires on fuse opening behavior. The optimum fuse design, including the optimum fuse wire diameter, will be discussed with a 20 Ohm resistive load as well as a vacuum diode load with similar impedance.

IEEE Conferences

Performance of a dual-stage helical flux compression generator under varying background gas and pressure

Authors: M. Elsayed; A. Neuber; C. Lynn; J. Korn; C. Anderson; A. Young; J. Dickens; M. Kristiansen; L. Altgilbers

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5958300

Abstract: Recent efforts at the Center for Pulsed Power and Power Electronics at Texas Tech University have been focused on the development of a compact and explosively driven High Power Microwave, HPM, system. The primary energy source (other than the seed energy source) driving the microwave load in this system is a mid-sized, dual-stage helical flux compression generator, HFCG. The HFCG has a constant stator inner diameter of 7.6 cm, a length of 26 cm, with a working volume of 890 cm3. Testing at the Center has revealed energy gains in the 30's and 40's with output energy levels in the kilo-joules regime into loads of several micro-Henries. Over the last few years, close to one hundred shots have been taken with these generators into various loads consisting of dummy inductive loads, power conditioning systems, and HPM sources. Throughout these tests, the working volume of the HFCG, i.e. the volume in between the wire stator and the explosive-filled aluminum armature, was filled with SF6 at atmospheric pressure. This was primarily done do avoid electrical breakdown in the generator volume during operation, resulting in flux loss. Recent design updates enable pressurizing the generator volume to pressures up to 0.5 MPa, which is needed, for instance, to replace the SF6 with other gases such as air or nitrogen. The performance of the dual-stage HFCG with pressurized working volume (SF6 and N2) is presented in this paper along with an analysis of the maximum electric field amplitude held off in the volume during operation. The design technique to seal the HFCG will also be briefly discussed.

IEEE Conferences

Pulsed Magnetic Field Excitation Sensitivity Of Match-Type Electric Blasting Caps

Authors: Parson, J; Dickens, J; Walter, J; Neuber, AA

PDF: https://aip.scitation.org/doi/10.1063/1.3499245

Abstract: This paper presents a study on energy deposition and electromagnetic compatibility of match-type electroexplosive devices (EEDs), which recently have found more usage in pulsed power environments with high electromagnetic interference (EMI) background. The sensitivity of these devices makes them dangerous to intended and unintended radiation produced by devices commonly used in pulsed power environments. Match-type EEDs have been found to be susceptible to such low levels of energy (7-8 mJ) that safe operation of these EEDs is vital when in use near devices that produce high levels of pulsed EMI. The scope of this paper is to provide an investigation that incorporates results of similar studies to provide detonation characteristics of these EEDs. The three topics included in this study are sensitivity testing, modeling of the thermodynamic heat propagation, and electromagnetic compatibility from pulsed electromagnetic radiation. The thermodynamic joule heating of the primary explosive has been modeled by a solution to the 1D heat equation. A simple pulsed generator, Marx generator with an inductive load, was used for the electromagnetic compatibility assessment of the coupled field between the pulse generator and shorted EED. The results of the electromagnetic compatibility assessment relate the resistive, inductive, and capacitive components of the pulse generator to the area of the shorted EED. (C) 2010 American Institute of Physics. [doi:10.1063/1.3499245]

Journal

Pulsed ring-down source array

Authors: A. Myers; J. Walter; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5958326

Abstract: A pulsed ring-down source array (PRDS), also called a Resonant Antenna-Source System, is a robust high-power transient RF transmitter that provides substantial power in the far field region. In a typical PRDS, a high potential is stored in the device structure and discharged through a switch, generating a damped ringing radiated waveform. Using an array of PRDS antennas, the radiated far field power density can be increased far beyond that possible with a single source. The array's performance is dependent on the individual antenna elements, along with the main switch triggering jitter and the jitter of the trigger source. The array being tested is composed of four antennas spaced a quarter wavelength apart from one another in a straight line. The PRDS element is a half coaxial monopole antenna tuned for ~100MHz. The switch used is a custom made trigatron spark gap pressurized up to 100 PSI of N2. The results presented from a working example of a PRDS array will enable future development of the system.

IEEE Conferences

Rapid charging seed source with integrated fire set for flux compression generator applications

Authors: S. L. Holt; M. A. Elsayed; B. Gaston; J. C. Dickens; A. A. Neuber; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5958312

Abstract: The design and testing of an integrated front-end power and control system for helical flux compression generators (HFCG) is presented. A current up to 12 kiloamps needs to be pushed into the 5.8 microhenry field coil of the HFCG to establish the necessary seed flux for generator operation. This current is created with the discharge of a 5 kilovolt, 50 microfarad metalized polypropylene film capacitor using a single-use semiconductor closing switch. Once peak current/flux is obtained in the seed coil an exploding bridge wire (EBW) detonator is initiated with a discharge from a 1 kilovolt, 500 millijoule capacitor array contained in the compact fire set. Both capacitances, seed and fire set, are charged using a rapid capacitor charger system. The rapid capacitor charger is a solid state step up converter supplied by lithium-ion polymer (LiPo) batteries. It provides the 5 kilovolts and 1 kilovolt dual output voltages required for the compact seed source and compact fire set, respectively. The rapid capacitor charger operates at an average output power of 3 kilowatts and charges both capacitances simultaneously in under 250 milliseconds. The rapid capacitor charger is reusable if protected from the explosive detonation.

IEEE Conferences

Spectral analysis of vacuum ultraviolet emission from pulsed atmospheric discharges

Authors: G. Laity; A. Neuber; G. Rogers; K. Frank; L. Hatfield; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5534416

Abstract: Summary form only given. It is commonly accepted that vacuum ultraviolet (VUV) radiation, corresponding to emission from 180 nm to 115 nm and below, is responsible for photoionization contributing to streamer propagation during the initial stages of atmospheric discharges. An experimental setup was constructed to observe the VUV emission of pulsed surface flashover along a dielectric surface between atmosphere and vacuum. However, VUV radiation is highly attenuated in the atmosphere, which makes observation of detailed spectra difficult. For VUV transmission down to 115 nm the light emitted by surface flashover across an MgF2 window (front side of window in air, backside in vacuum) was focused by an MgF2 lens onto the entrance slit of the spectrograph. The high speed detection scheme consists of a VUV sensitive ICCD camera and a photomultiplier, both with nanosecond temporal resolution. Spectra were measured in various gas mixtures at atmospheric pressure with a flashover spark length of about 8 mm with a 35 kV pulsed excitation, and spectral calibration was done utilizing a VUV calibration lamp with a known emission spectrum. Virtually all lines from 115 to 180 nm can be identified as atomic oxygen and nitrogen transitions during flashover in dry air, with most VUV emission occurring during the initial breakdown stage (current rise). The extremely fast decay of VUV emission intensity following this initial stage is evidence of radiationless quenching of the excited energy levels associated with the observed spectral lines. Flashover studies were also performed in pure oxygen and nitrogen environments to reinforce the observed emission trends. Spectroscopy must be carefully detailed, for instance, the Oxygen-I line at 130.2 nm (which corresponds to a ground level transition) is shown to be strongly self absorbed in the atmospheric spark when compared to a similar oxygen emission line at 130.4 nm. Full spectra were simulated using SpectraPlot, a temperature dependent spectral software suite developed at Texas Tech. It has been concluded from the comparison of simulated and measured Nitrogen spectra between 140 and 150 nm that the electronic temperature is about 4.5 eV, assuming that the electronic nitrogen energy level population density is Boltzmann distributed. The measured spectra will be discussed in relation to the physics of surface flashover and volume breakdown at atmospheric pressure.

IEEE Conferences

Synchronization of phased array pulsed ring-down sources using a GPS based timing system

Authors: Y. Chen; J. Dickens; S. Holt; D. Reale; J. Mankowski; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5958436

Abstract: A collaborative effort at Texas Tech University on high power RF transmitters has directly translated to the development of phased array pulsed ring down sources (PRDS). By operating an array of PRDS, peak radiating power on target can theoretically be multiplied by the number of sources. The primary limitation on the application of the array concept is the jitter with which the individual sources can be fired. An ideal jitter of a small fraction of the risetime is required to accurately synchronize the array to steer and preserve the risetime of the radiated pulse. This paper describes in detail the implementation of a GPS based timing system that will synchronize the individual antennas to operate at different geo-locations to function in a coordinated fashion to deliver the peak power of each element to a single position. Theoretical array performance is shown through Monte Carlo simulations, accounting for switch jitter and a range of GPS timing jitter. Each module will include a control unit, low jitter pulser, low jitter spark gap, antenna element, as well as a GPS receiver. The location of each module is transmitted to a central controller, which calculates and dictates when each element is fired. Low jitter in the timing of the GPS reference signal is essential in synchronizing each element to deliver the maxim power. Testing using a preliminary setup using GPS technology is conducted with both 1 pps and 100 pps outputs. Jitter results between modules are recorded to ~10 ns without any correction factors. With the timing and geospatial errors taken into account, the proposed concept will show usable gains of up to several hundred MHz.

IEEE Conferences

Theoretical performance of a GPS linked Pulsed Ring Down Array

Authors: D. Reale; J. Mankowski; S. Holt; Y. Chen; J. Walter; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5958437

Abstract: Current research at Texas Tech University is focused on the development of a High-Power Pulsed Ring-Down Source (PRDS) Antenna Array. Previously, a Monte Carlo based analysis was conducted in order to predict the array performance based upon the estimated switching jitter between elements. This analysis showed good performance for jitter times between 0 to 2 periods of the ringing frequency. Therefore, for ringing frequencies up to 500 MHz, jitter times up to 4 nanoseconds can be tolerated. Subsequently, we have shown practical switching solutions capable of the sub-nanosecond switching performance needed for the frequencies of interest. Taking the analysis a step further, we introduce the uncertainty of the absolute position of each antenna element. To implement a randomly distributed array, where the position of elements is not fixed, a method of accurately resolving element positions relative to each other and the target location is required. The use of a variety of GPS technologies and techniques is explored as a method for position and timing resolution. The relative accuracy between elements and the absolute accuracy of each element is discussed. A Monte Carlo based analysis is conducted to predict array performance based upon GPS positional error, GPS timing error, and switch jitter.

IEEE Conferences

VUV Emission and Streamer Formation in Pulsed Dielectric Surface Flashover at Atmospheric Pressure

Authors: Truman G. Rogers; Andreas A. Neuber; Klaus Frank; George R. Laity; James C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=5559489

Abstract: There is a growing interest in the physics of surface flashover between the interface of atmosphere and vacuum in some high-power systems. More specifically, the quantitative role of vacuum ultraviolet (VUV) radiation for the photoionization leading to a streamer development during the initial stages of a breakdown is unknown. This paper describes an experimental setup used to measure the VUV radiation emitted from atmospheric flashover as well as time-resolved imaging of the flashover event. A pulser providing the voltage to the gap was designed with special considerations in mind, including long lifetime, low noise, and high reproducibility. This enabled the study of the flashover in various background gases with an emphasis on spectroscopic measurements. The calculated spectra are compared with the measured spectra, and it is found that atomic oxygen and nitrogen are responsible for most of the VUV production in an air breakdown at atmospheric pressure in the wavelength range of 115-180 nm. Time-resolved spectroscopy reveals that the VUV radiation is emitted during the initial stages while the streamers are developing.

Journals

2009

A compact 5kV battery-capacitor seed source with rapid capacitor charger

Authors: S. L. Holt; J. C. Dickens; J. L. McKinney; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5386260

Abstract: Many pulsed power applications have demanding system requirements. Power systems for these applications are expected to provide high energy, high pulsed power and long standby times without recharge, all in a very compact package. The different properties of batteries and capacitors make them most suitable for different uses. When selecting a prime power source for compact pulsed power systems a hybrid system often provides the optimal solution, utilizing a battery for prime energy storage during standby and a capacitor for intermediate energy storage before and between operations. This system takes advantage of the best characteristics of both sources to fulfill the system requirements. The design and testing of such a compact system is discussed. The system utilizes a solid-state converter to charge a 50 ¿F polypropylene capacitor to 5 kV in under 500 ms from lithium-ion polymer (LiPo) batteries. Battery selection and testing is also covered. The battery and charger assembly occupies 1.25 L while the capacitor occupies an additional 1.4 L.

IEEE Conferences

Electrical conduction in select polymers under shock loading

Authors: C. Lynn; A. Neuber; J. Krile; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=5386199

Abstract: It is known that polymers become conductive under shock loading, which can be critical to the operation of explosive driven high current/voltage devices. Hence, the propensity of several select polymers to conduct under shock loading was investigated. Four polymers, Nylon, Teflon, Polypropylene, and High Density Polyethylene, were tested under shock pressures up to ~22 GPa. Shock waves were generated with high explosives, and CTH, a hydrodynamic code developed at Sandia National Laboratories, was utilized to calculate pressure and temporal resolution of the shock waves. Time of arrival measurements of the shock waves were taken to correlate the hydrodynamic calculations with experimental results. A notable delay between shock front arrival and the onset of conduction is exhibited by each polymer. The delay tends to decrease with increasing pressure down to approximately 500 ns for HDPE at ~22 GPa under electric field strength of ~6.3 kV/cm. The data shows that some polymers exhibit more delay than others, thereby indicating better insulating properties under shock loading. Additionally, experiments revealed that the polymers conducted for a finite time on the microsecond time scale before recovering back to an insulating state. This recovery from a shock wave induced conducting state back to insulating state was investigated for a possible opening switch application.

Conferences

Energy deposition assessment and electromagnetic evaluation of electroexplosive devices in a pulsed power environment

Authors: J. Parson; J. Dickens; J. Walter; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=5386262

Abstract: This paper assesses critical activation limits of electroexplosive devices (EED), such as blasting caps, which have recently found more usage in pulsed power environments with high EMI background. These devices, EEDs, can be very sensitive to low levels of energy (7-8 mJ) which make them dangerous to unintended radiation produced by compact pulsed generators. Safe operation and use of these devices are paramount when in use near devices that produce pulsed electromagnetic interference. The scope of this paper is to provide an evaluation of activation characteristics for EEDs that include energy sensitivity tests, thermodynamic modeling, and electromagnetic compatibility from pulsed electromagnetic interference. Two methods of energy deposition into the bridgewire of the EED are used in the sensitivity tests. These methods include single and periodic pulses of current that represent the adiabatic and non-adiabatic heating of the bridgewire. The heating of the bridgewire is modeled by a solution to the heat equation using COMSOL¿ with physical geometries of the EED provided by the manufacturer.

Conferences

High electric field packaging of silicon carbide photoconductive switches

Authors: C. Hettler; C. James; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=5386380

Abstract: Photoconductive semiconductor switches (PCSS) made from semi-insulating (SI) silicon carbide (SiC) are promising candidates for high frequency, high voltage, and low jitter switching. However, existing switches fail at electric fields considerably lower than the intrinsic dielectric strength of SiC (3 MV/cm) because of the field enhancements near the electrode-semiconductor interfaces. Various geometries were identified which could reduce the electric field near the contact regions. The switches were simulated with various parameters and compared. In all cases, it was determined that a high dielectric constant (high-k) encapsulant is a crucial requirement that reduces high fields within the bulk material while inhibiting surface flashover. Assorted high-k encapsulants were evaluated and a portion was subsequently tested in the lab. The observed dielectric strength and relative permittivity of the encapsulants are presented. Pseudo switches, employing sapphire substrates, were constructed and biased to electrical breakdown. The dielectric strength of the interface between the semiconductor and the encapsulant was tested and improvements were discussed.

Conferences

High voltage photoconductive switches using semi-insulating, vanadium doped 6H-SiC

Authors: C. James; C. Hettler; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=5386303

Abstract: SiC manufacturers are continually improving the purity of their wafers, however, interband impurities, while detrimental in many applications, can be useful in the operation of photoconductive switches. Compact, high-voltage photoconductive switches were fabricated using c-plane; vanadium doped 6H-SiC obtained from II-VI, Inc. This material incorporates a large amount of interband impurities that are compensated by the vanadium amphoteric, but at present is only available as c-plane wafers. In order to avoid micropipe defects, lateral switches were fabricated to allow validation of material simulations. Low resistivity contacts were formed on the semi-insulating material and a high-voltage encapsulant increases the surface flashover potential of the switch. Material characteristics were determined and switch parameters were simulated with comparisons made to experimental data.

Conferences

Low jitter triggered spark gap with high pressure gas mixtures and Kr85

Authors: Y. Chen; J. C. Dickens; J. W. Walter; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5227620

Abstract: Summary form only given. A recent research effort at Texas Tech University on impulse antenna phased arrays has necessitated the need to develop a reliable high voltage, high repetition rate switch that will operate with ultra low jitter. An ideal jitter of a small fraction of the risetime is required to accurately synchronize the array to steer and preserve the risetime of the radiated pulse. A 50 Omega, 1 nF pulse forming line is charged to 50 kV and provides the low inductance voltage source to test the different gases. Triggering is provided by a solid state opening switch voltage source that supplies ~80 kV, 10 ns risetime pulses at a rep rate up to 100 Hz in burst mode. A hermetically sealed spark gap with a Kel-F lining is used to house the switch and high pressure gas. Previously, the system was successfully tested with 50 kV, 100 Hz switch operations. Gases tested include, dry air, H2, N2, and SF6, as well as H2-N2, and N2-SF6 gas mixtures. A discussion on switch operation time and switch gas temperature vs. jitter will be included in this paper. This paper will also discuss in detail the effects on switch jitter when different concentrations of Kr85 gas are introduced.

IEEE Conferences

Optimization of a low jitter, 50 kV, 100 Hz triggered spark gap with high pressure gas mixtures

Authors: Y. Chen; J. Dickens; J. Mankowski; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5211842

Abstract: Recent research efforts at Texas Tech University on impulse antenna phased array has needed to develop a reliable high voltage, high repetition rate switch that will operate with ultra low jitter. An ideal jitter of a small fraction of the risetime is required to accurately synchronize the array to steer and preserve the risetime of the radiated pulse. In, we showed the initial test system with sub-ns results for operations in different gases and gas mixtures. This paper discusses in detail 50 kV, 100 Hz switch operations with different gases. The effects of gases and gas mixtures have on switch performance which includes recovery rate and in particular jitter will be investigated. Gases tested include, dry air, H2, N2, and SF6, as well as H2-N2, and N2-SF6 gas mixtures. Switch jitter as a result of triggering conditions is discussed, also including a comprehensive evaluation of jitter as a function of formative delay in the various gases. The temperature of gas and its effects on switch jitter is also documented in this paper. A 50 ¿, 1 nF pulse forming line is charged to 50 kV and provides the low inductance voltage source to test the different gases. Triggering is provided by a solid state opening switch voltage source that supplies ~150 kV, 10 ns risetime pulses at a rep rate up to 100 Hz in burst mode. A hermetically sealed spark gap with a Kel-F-PCTFE (polychlorotrifluoroethylene) lining is used to house the switch and high pressure gas.

IEEE Journals

Optimization of an FCG-Based High-Power Microwave System Using Nonexplosive Pulsed Power

Authors: C. B. Davis; A. A. Neuber; A. Young; J. Walter; J. C. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5313897

Abstract: This paper presents a nonexplosive pulsed-power system that replicates the output current waveform of a flux compression generator (FCG). The primary purpose of this system is to efficiently test the power conditioning components of an explosively driven HPM system, while drastically reducing the time between tests which are inherent with explosive experiments. The power conditioning system (PCS) of the HPM system includes an energy-storage inductor, an electroexplosive opening switch (fuse), and a peaking gap and serves to match the FCG output characteristics with the HPM diode load requirements. A secondary purpose of the nonexplosive test bed is to provide data points which could be directly compared with those from explosively driven experiments. For this reason, a reflex-triode virtual cathode oscillator (vircator) was connected to the output of the nonexplosive system, and the results of which were compared with similar testing done with an FCG and a compact Marx generator. Since the behavior of the fuse is known to play a critical role in the performance of the PCS, a study was performed on the effect of different fuse designs on the overall performance of the PCS. Specifically, the quality of the electrical connection between the fuse wire array and the rest of the system was tested. Fuse design experiments were conducted with the nonexplosive test bed firing into a water resistor dummy load, which showed a 13% increase in peak load voltage and more than an 11% increase in energy transfer for fuses with improved wire-electrode connection strength. Some basic rules about fuse design, as well as conclusions on the performance of the PCS when driving an HPM load, are given.

IEEE Journals

Optimizing power conditioning components for a Flux Compression Generator using a non-explosive testing system

Authors: C. Davis; A. Neuber; A. Young; J. Walter; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=5386110

Abstract: This paper discusses a non-explosive pulsed power device used to reproduce the output waveforms of a Flux Compression Generator (FCG) driving a High Power Microwave (HPM) source. This system optimizes the power conditioning components of a HPM source while reducing the time and resources inherent to explosively driven FCG schemes. An energy storage inductor, fuse opening switch, and a peaking gap make up the power conditioning system. This system couples large voltage pulses (~300 kV), suited for HPM sources, to the load by disrupting the energy storage inductor current (~40 kA). This paper will show that an optimal fuse length was experimentally searched for by varying the calculated fuse wire base length by ±5, 10, and 15%. Various geometric fuse designs were examined to achieve a 45% reduction in the physical fuse length at constant wire length with acceptable performance losses. This paper will also show that the distance between the electrodes of a peaking gap can be optimized to more efficiently switch in the load. Finally results will be shown that depict the amount of microwave power produced by a vircator before fuse and peaking gap optimization.

Conferences

Performance of a compact triode vircator and Marx generator system

Authors: J. Walter; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=5386184

Abstract: Vircator high power microwave sources are simple, robust, and require no external magnetic field, making them desirable for use in practical compact high power microwave systems. A vircator can be driven directly from the output of a low-impedance Marx generator, eliminating the need for bulky intermediate energy storage components. A compact high power microwave system has been constructed and tested at Texas Tech University utilizing a triode geometry vircator and a compact Marx Generator. The size and performance of this system is compared to a similar system previously developed at Texas Tech. The current triode vircator is housed within a six inch diameter tube which is eleven inches in length. The Marx is contained in an oil tank that is 36 inches long × 12 inches wide × 18 inches tall. Diode voltage and current, and radiated microwave waveforms are presented.

Conferences

Prediction of compact explosively-driven ferroelectric generator performance

Authors: D. Bolyard; A. Neuber; J. Krile; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5386196

Abstract: Explosively-driven ferroelectric generators are attractive as potential prime energy sources for one-time use pulsed power systems. While the output voltages of small ferroelectric discs have been shown to be on the order of the theoretical maximum values, scaling the ferroelectric to larger thicknesses has proven less successful. The primary limiting factor is how much of the ferroelectric material is compressed simultaneously. This is difficult to control for thicker ferroelectric discs or stacks of discs due to pressure pulse attenuation in the material and rarefaction waves shortening the pressure pulse. A hydrodynamic code system is utilized to calculate the temporally and spatially resolved pressure. The calculated pressure values are converted into voltage produced by the ferroelectric through an algorithm based on an empirical polarization-pressure hysteresis curve. The validity of the algorithm has been verified for PZT EC-64 with experimental data from a flyer-plate experiment reported in literature and our own experiments with the shock wave from the explosives more directly applied to the ferroelectric. Both calculations and experiments produced normalized output voltages, ranging from 1.4 to 3.4 kV/mm for 2.54 cm diameter discs. We will discuss how this pressure to voltage algorithm along with pressure simulations aided in the scaling of the amount of ferroelectric material in a generator, as well as in the design of new driver elements with the goal to increase the peak output voltage of a generator while keeping the generator compact. The calculated voltage output results are compared with experimental data of explosively-driven ferroelectric generators.

IEEE Conferences

Stand-alone, FCG-driven High Power Microwave system

Authors: A. Young; A. Neuber; M. Elsayed; J. Walter; J. Dickens; M. Kristiansen; L.L. Altgilbers

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=5386301

Abstract: An explosively driven High Power Microwave (HPM) source has been developed that is based on the use of a Flux Compression Generator (FCG) as the primary driver. Four main components comprise the HPM system, and include a capacitor-based seed energy source, a dual-staged FCG, a power conditioning unit and an HPM diode (reflex-triode vircator). Volume constraints dictate that the entire system must fit within a tube having a 15 cm diameter, and a length no longer than 1.5 m. Additional design restrictions call for the entire system to be stand-alone (free from any external power sources). Presented here are the details of HPM system, with a description of each subcomponent and its role in the generation of HPM Waveforms will be shown which illustrate the development of power as it commutates through each stage of the system, as well as power radiated from the diode. Analysis and comparisons will be offered that will demonstrate the advantages of an explosively driven HPM system over more conventional pulsed power devices.

Conferences

VUV emission from dielectric surface flashover at atmospheric pressure

Authors: G. Rogers; A. Neuber; G. Laity; J. Dickens; K. Frank; T. Schramm

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=5386373

Abstract: Spectroscopic measurements in the vacuum ultraviolet (VUV) regime are difficult to make due to extremely large absorption of VUV radiation in most materials. This paper describes an experimental setup designed for studying the optical emission during pulsed surface flashover for the wavelength range between 115 nm to 180 nm at atmospheric pressures with a focus on the scheme used to excite the spark gap. The surface flashover of interest occurred on an MgF2 window (front side of window in air, backside in vacuum) imaged onto the entrance slit of a 1 m vacuum spectrograph. Emission spectra were recorded with an Andor DH740 series ICCD camera. All data was taken at atmospheric pressure with a flashover spark length of about 8 mm created by a pulser designed for a 500 ns pulse, max 50 kV output. The centerpiece of this pulser is the CCSTA14N40 thyristor by Solidtron/Silicon Power which features a rate of change current of maximum 30 kA/¿s and a hold-off voltage of up to 4 kV. A pulse transformer with Metglas® core was used to elevate the voltage to 50 kV with a rise time of 180 ns and a peak current of 500 A. The pulser was designed for a repetition rate of 10 Hz and is triggered by TTL pulses. Discussed in this paper, along with the measured spectra and their relation to the physics of surface flashover at atmospheric pressure, will be the design of the pulser.

Conferences

Vacuum ultraviolet spectroscopy of dielectric surface flashover at atmospheric pressure

Authors: G. Laity; K. Frank; G. Rogers; M. Kristiansen; J. Dickens; A. Neuber; T. Schramm

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=5227565

Abstract: Summary form only given. Spectroscopic measurements in the vacuum ultraviolet (VUV) regime are difficult to make due to extremely large absorption of VUV radiation in most materials. This paper describes an experimental setup designed for studying the optical emission during pulsed surface flashover for the wavelength range between 115 nm to 300 nm at atmospheric pressures. A vacuum monochromator VM 505 from Acton Research Corporation was used as the spectrograph. For VUV transmission down to 115 nm the light emitted by surface flashover across an MgF2 window (front side of window in air, backside in vacuum) was focused by an MgF2 lens onto the entrance slit of the spectrograph. A quartz window with sodium salicylate coating exposed to the spectrograph's vacuum was placed in the exit focal plane of the collimating mirror of the spectrograph. This fluorescent coating down-converts the VUV light to longer wavelengths that were recorded with an Andor DH520 series ICCD camera in combination with a Nikon 105 mm lens. Spectra were measured at atmospheric pressure with a flashover spark length of about 9 mm and DC excitation with a capacitance of 4.1 nF. Emission spectra were measured from 300 nm down to 130 nm. In parallel, theoretical spectra were calculated primarily for the identification of radiating species and their temperature. Utilizing the NIST Atomic Spectra Database (ASD) data a library of temperature dependent optical emission spectra was generated with SpectraPlot, a spectral software suite developed at TTU. VUV spectral lines of nitrogen, carbon, magnesium and silicon were identified. In pure nitrogen, for instance, the nitrogen I double line at 174.3 nm and 174.5 nm is clearly visible in the spectrum along with a strong double line at 279.6 nm and 280.4 nm, which is emitted by Magnesium II, eroded from the surface exposed to flashover. Spectra were measured in ambient air, pure nitrogen, and argon. An experiment upgrade is currently underway, increasing the VUV sensitivity of the setup. The measured spectra will be discussed in relation to the physics of surface flashover and volume breakdown at atmospheric pressure.

IEEE Conferences

2008

A 50 kV, 100 Hz Low Jitter Triggered Spark Gap with High Pressure Gas Mixtures

Authors: Y. Chen; J. J. Mankowski; J. C. Dickens; J. Walter; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4743614

Abstract: Recent research efforts at Texas Tech University on impulse antenna phased array has necessitated the need to develop a reliable high voltage, high repetition rate switch that will operate with ultra low jitter. An ideal jitter of a small fraction of the risetime is required to accurately synchronize the array to steer and preserve the risetime of the radiated pulse. In (Y. Chen et al., 2007), we showed the initial test system with sub-ns results for operations in different gases and gas mixtures. This paper presents the impact gases and gas mixtures have on switch performance which includes recovery rate and in particular jitter. A 50 Omega, 1 nF pulse forming line is charged to 50 kV and provides the low inductance voltage source to test the different gases. Triggering is provided by a solid state opening switch voltage source that supplies ~150 kV, 10 ns risetime pulses at a rep rate up to 100 Hz in burst mode. A hermetically sealed spark gap with a Kel-F lining is used to house the switch and high pressure gas. This paper discusses in detail 50 k, 100 Hz switch operations with different gases. Gases tested include, dry Air, H2, N2, and SF6, as well as H2-N2, and N2-SF6 gas mixtures. Switch jitter as a result of triggering conditions is discussed, also including a comprehensive evaluation of jitter as a function of formative delay in the various gases.

IEEE Conferences

A Compact, Self-Contained High Power Microwave Source Based on a Reflex-Triode Vircator and Explosively Driven Pulsed Power

Authors: A. Young; T. Holt; M. Elsayed; J. Walter; J. Dickens; A. Neuber; M. Kristiansen; L.L Altgilbers; A.H. Stults

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4743600

Abstract: Single-shot high power microwave (HPM) systems are of particular interest in the defense industry for applications such as electronic warfare. Virtual cathode oscillators (vircators) are manufactured from relatively simple and inexpensive components, which make them ideal candidates in single-shot systems. The flux compression generator (FCG) is an attractive driver for these systems due to its potential for high energy amplification and inherent single-shot nature. A self-contained (battery operated prime power), compact (0.038 m3), FCG-based power delivery system has been developed that is capable of delivering gigawatts of power to a vircator. Experiments were conducted with the delivery system connected to a resistive dummy load and then to a reflex-triode vircator. In order to optimize the performance of the vircator when driven by the power delivery system, a second experimental setup was constructed using a Marx-generator based system operating at similar voltages and rise-times. Performance measures of the delivery system when discharged into a resistive load will be presented, as well as vircator output power levels and waveforms from both experimental setups.

Conferences

Analysis of Mesoband Single Element Pulsed Ring-Down Antennas for Implementation in Phased Array Systems

Authors: D. Belt; J. Mankowski; J. Walter; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4743602

Abstract: In recent years, the pulsed ring-down antenna has become of great interest due to its compact size and high power on target potential. Since these systems are fairly new in study, it is often difficult to predict the overall performance without experimental evaluation. A pulsed ring-down antenna operates by charging the single element antenna with a high potential source and then closing a switch to develop transient wave reflections on the antenna, typical CW case analysis does not apply. For this reason, we have constructed a simulation model that allows us to predict the transient behavior of the structure. By utilizing the Comsol RF module transient analysis functions, we are able to characterize various parameters of different antennas, beginning with a dipole pulsed ring-down antenna operating around the 100 MHz range. After examining the simulated results against the experimental results for accuracy, we then moved to more complicated mesoband antenna structures. The simulation model developed within the COMSOL RF module allows us to examine various influential factors such as material losses, transient switching effects, structure capacitance, switch capacitance, and initial charging losses. With this, we are able to examine methods to improve the results in the far field such as capacitive spark gap loading and other capacitive storage methods. Utilizing the pulsed ring-down antenna model, we are able to give a better characterization of mesoband pulsed ring-down structures for implementation into a specific or multi-purpose phased array system.

Conferences

Compact Electroexplosive Fuses for Explosively Driven Pulsed Power

Authors: D. R. McCauley; D. W. Belt; J. J. Mankowski; J. C. Dickens; A. A. Neuber; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4663131

Abstract: Compact electroexplosive fuses (EEFs) as part of an explosively driven system are of interest for the one-time single-shot generation of high-power pulses. For instance, the transition from a very large driving current produced by an explosively driven flux compression generator (FCG), i.e., low impedance, to a large voltage spike delivered to the load, i.e., high impedance, can be done using an inductive storage system and an EEF. Typically, the EEF can be as large as, if not larger than, the current driver attached to it, thus making it one of the largest components in the system. Reduction in the size of the fuse will allow for size reductions of the entire high-power microwave (HPM) system. The goal of optimizing an EEF as an opening switch is to produce the greatest voltage multiplication possible to drive a load under physical size constraints. To optimize the fuse, several parameters are taken into account, including, but not limited to, fuse material, fuse length, fuse shape, and quenching medium. Individual optimization of these parameters will lead to complete optimization of an EEF, therefore resulting in a compact fuse capable of consistently producing maximum voltage multiplication for HPM systems.

IEEE Journals

Compact Silicon Carbide Switch For High Voltage Operation

Authors: C. James; C. Hettler; J. Dickens; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4743565

Abstract: Vanadium compensated, 6H silicon carbide (SiC) is investigated as a compact, high-power, linear-mode photoconductive semiconductor switch (PCSS) material. SiC is an attractive material due to its high resistivity, high electrical breakdown strength, and long recombination times compared to other photoconductive materials. The PCSS is designed for fast-rise time, low-jitter (sub-nanosecond) operation in a matched 50 mu test bed. Ohmic contacts were applied by physical vapor deposition and initial test utilized an external Nd:YAG laser trigger source. Analysis of the optical properties of Va-compensated SiC and of switch conduction resistance are presented and performance of contact material is discussed.

IEEE Conferences

Energy Deposition and Electromagnetic Compatibility Assessment of Electroexplosive Devices

Authors: J. Parson; J. Dickens; J. Walter; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4743684

Abstract: This paper assesses the critical activation energy required to set off electroexplosive devices (EED) at constant joule heating and rates of joule heating. Safe operation and use of these devices are of great concern in and around pulsed electromagnetic interference. Sensitivity characterization of EEDs include firing sensitivity plots, thermodynamic modeling and electromagnetic interference. Activation energy evaluation of single and periodic rectangular pulses are included to represent adiabatic and non-adiabatic bridge wire heating of the EED. The scope of this paper is to provide a short overview of sensitivity, thermodynamic, and electromagnetic compatibility of EEDs. The results provide crucial information in evaluating energy induced by pulsed electromagnetic fields of compact pulse generators.

Conferences

High-Current Compact FCG Seed Source Implementing Solid State Switching

Authors: M. Elsayed; T. Holt; A. Young; A. Neuber; J. Dickens; M. Kristiansen; L. L. Altgilbers; A. H. Stults

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4743567

Abstract: Flux Compression Generators (FCGs) are some of the most attractive sources of single-use compact pulsed power available today due to their high energy density output and mobility. Driving FCGs requires some seed energy, which is typically provided by applying a high seed current, usually in the kilo-Ampere range for mid-sized helical FCGs. This initial current is supplied by a high-current seed source that is capable of driving an inductive load. High-current seed sources have typically been comprised of discharging large capacitors using spark-gaps and over-voltage triggering mechanisms to provide the prime power for FCGs. This paper will discuss a recent design of a self-contained (battery powered with full charge time less than 35 sec), single-use Compact Seed Source (CSS) using solid state components for the switching scheme developed at the Center for Pulsed Power and Power Electronics at Texas Tech University. The CSS developed is a system (0.007-m3 volume and weighing 13 lbs) capable of delivering over 250-J (~10 kA) into a 6-muH load with a trigger energy of micro-Joules at the TTL triggering level. The newly designed solid-state switching scheme of the CSS incorporates off-the-shelf high-voltage semiconductor components that minimize system cost and size as necessary for a single-use application. An in-depth and detailed evaluation of the CSS is presented primarily focusing on the switching mechanics and experimental characterization of the solid state components used in the system.

IEEE Conferences

Imaging of the Explosive Emission Cathode Plasma in a Vircator High-Power Microwave Source

Authors: J. Walter; J. Mankowski; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4599124

Abstract: Most pulsed high-power microwave sources use explosive electron emission cathodes to generate high current electron beams. In the explosive emission process, the current emitted through small field emission points becomes high enough to cause the cathode material to vaporize and form a plasma. Plasma characteristics, such as uniformity and expansion rate, will affect the performance of the microwave source. High-speed optical imaging can be used to resolve some characteristics of the plasma in time. The images of the cathode plasma during the operation of a triode-geometry virtual cathode oscillator high-power microwave source are presented for three different cathode materials.

IEEE Journals

Jitter and recovery rate of a 50 kV, 100 Hz triggered spark gap with high pressure gas mixtures

Authors: Yeong-Jer Chen; John J. Mankowski; John W. Walter; James C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4590809

Abstract: Summary form only given.Recent attention to impulse antenna phased array has necessitated the need to develop a reliable high voltage, high repetition rate switch that will operate with ultra low jitter. An ideal jitter of a small fraction of the rise time is required to accurately synchronize the array to steer and preserve the rise time of the radiated pulse. This paper presents the impact gases and gas mixtures have on switch performance which includes recovery rate and in particular, jitter. A 50 Omega, 1 nF pulse forming line is charged to 50 kV and provides the low inductance voltage source. Triggering is provided by an SOS voltage source that supplies >100 kV, 10 ns rise-time pulses at a rep rate up to 1 kHz in burst mode. A hermetically sealed spark gap with a Kel-F lining is used to house the switch and high pressure gas. The system includes a gas mixing chamber that can mix various gases up to 2000 psi. Gases tested include dry air, H2, N2, and SF6. Initial testing with 30 kV, 10 Hz switch operations have shown reliable sub-ns jitter times with pure gases including dry air, H2, N2, and with H2-N2, and N2-SF6 gas mixtures. The system was then modified for 50 kV, 100 Hz operations with no recovery issues. Jitter data for pure gases, H2-N2, N2-SF6, and various Kr85 gas mixtures at the 50 kV, 100 Hz operation is also documented and compared in this paper.

Conferences

Low-Jitter Triggered Spark Gap With High-Pressure Gas Mixtures

Authors: Y. Chen; J. J. Mankowski; J. C. Dickens; J. Walter; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4663175

Abstract: Recent attention to impulse antenna phased array has necessitated the need to develop a reliable high-voltage high-repetition-rate switch that will operate with ultralow jitter. An ideal jitter of a small fraction of the rise time is required to accurately synchronize the array to steer and preserve the rise time of the radiated pulse. This paper presents the impact that gases and gas mixtures have on switch performance which includes recovery rate and, in particular, jitter. A 50-Omega 1-nF pulse-forming line is charged to 30 kV and provides the low inductance voltage source to test the different gases. Triggering is provided by a solid-state opening switch voltage source that supplies >100-kV 10-ns rise-time pulses at a rep rate of up to 1 kHz in burst mode. A hermetically sealed spark gap with a Kel-F lining is used to house the switch and high-pressure gas. The system includes a gas-mixing chamber that can mix various gases up to 2000 psi. Gases tested include dry air, H2, N2, and SF6. Switch operations in 30 kV and 10 Hz have shown reliable subnanosecond jitter times with pure gases, including dry air, H2, N2, and with H2 - N2 and N2 - SF6 gas mixtures. The system was then modified for 50-kV 100-Hz operations with data collected for each of the pure gases. Recovery was monitored with no major problems at the 100-Hz operation, and subnanosecond jitter results for H2 , N2, and SF6 are also recorded.

IEEE Journals

Opening Switch Utilizing Stress Induced Conduction in Polymethylmethacrylate

Authors: C. Lynn; J. Krile; A. Neuber; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4743696

Abstract: It is known that polymethylmethacrylate, PMMA, becomes conductive under shock loading. To develop an opening switch utilizing shock induced conduction, the reversibility of this process must be studied. It is suggested in literature that changes in electrical properties begin at pressures as low a ~2 GPa. Applying the minimum pressure necessary for conduction is desirable in order to maximize the reversibility by limiting compression heating of the material. CTH, a hydrodynamic code written at Sandia National Laboratory, was used to design various drivers that deliver pressures in the range of ~2 GPa to ~6 GPa to the PMMA. By utilizing the switch to trigger an RC discharge, the resistance and on-time of the switch was characterized. Experiments have shown conduction durations on the order of ~4 mus. The switch was then placed into a capacitive driven inductive energy storage circuit, IES, to determine the polymer's ability to recover. This paper will present experimental data, CTH simulation results, and discuss the attained switching characteristics under varying shock pressure profiles.

IEEE Conferences

Scaling and Improvement of Compact Explosively-Driven Ferroelectric Generators

Authors: D. Bolyard; A. Neuber; J. Krile; J. Walter; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4743573

Abstract: Explosively-driven ferroelectric generators are capable of producing single-shot voltage pulses of more than 100 kV, while requiring no seed electrical source, being very compact, and shelf stable. Problems with ferroelectric generators are the low energy output, high dielectric constant of the ferroelectric material, low surface flashover voltage, inconsistent ferroelectric material quality, and uneven or excessive shockwave compression. Initial generator voltage waveforms show that breakdown occurred towards the end of the generator operation time. Several designs and methods have been tested and implemented to prevent surface flashover with varying results. The ferroelectric discs used for the generators were 0.4 inch thick, 1 inch diameter EC-64 PZT ceramic discs. Several six-disc generators were built and tested with resulting open-circuit voltage pulses of 80-140 kV with a FWHM of 2-4 mus. Further improvements to the generators have been designed to prevent surface flashover, improve the explosive driver element and propagating shockwave, as well as increasing the number of discs per generator. Measured output waveforms into varying loads including direct driven antennas will be shown and discussed.

IEEE Conferences

Secondary Arc Formation Within a Distributed Energy Railgun

Authors: Ryan W. Karhi; John J. Mankowski; James C. Dickens; Magne Kristiansen; David A. Wetz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4667685

Abstract: Experimental results comparing a breech-fed scheme and two distributed energy schemes for a free-running arc are presented. Analysis and observations of the issues associated with distributed energy switching of a plasma arc in the railgun are explored. The use of a free-running arc allows experiments to emulate the ablation and restrike phenomenon of a plasma armature railgun at high speeds (> 5 km/s) without the requirement of a large amount of stored energy. Numerous experimental tests were conducted to investigate the dynamics of plasma arcs within a distributed energy source railgun. Variations of switch timing, bore pressure, bore material, current amplitude, and current pulse length within each stage have been tested. These data reveal important design parameters for distributed energy railguns. The arc length, stage length, and stage trigger timing play a crucial role in distributed energy railgun performance. Failure to take these parameters into consideration will result in velocity reduction through plasma arc restrike and/or splitting.

Journals

Shock Wave Simulation of Ferrite-Filled Coaxial Nonlinear Transmission Lines

Authors: W. Sullivan; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4743706

Abstract: Ferrite-filled coaxial shock lines have recently been used to significantly decrease the rise time of a high voltage pulse. This decrease can be enhanced by initially axially biasing the ferrite material with an applied external magnetic field, allowing for a faster transition from the unsaturated to the saturated state. The simulation of the ferrite material's operation, including saturation, is discussed as well as the simulation of coaxial nonlinear transmission lines. The project explores the rise time changes with variations of magnetic bias, ferrite geometry, input signal characteristics, and transmission line characteristics. Simulated waveforms are discussed for a nickel-zinc ferrite-filled coaxial line. The pulse steepening effect observed in electromagnetic shock lines occurs primarily because of an increase in phase velocity for points higher on the waveform due to the saturation of the ferrite material. An incident pulse of high enough amplitude will drive the ferrite material into saturation, decreasing the relative permeability to one. This saturation front propagates through the ferrite material in the direction of the incident wave until the entire material is saturated, producing a sub-nanosecond rise time pulse. The shock line is designed for a saturated impedance of 50 Ohms to couple easily into existing systems. Pulsed operation of up to low kilohertz repetition is desired and being explored. Applications of electromagnetic shock lines include laser triggering and ultra-wideband radar generation, as well as others.

Conferences

Utilization of a Nonexplosive Test Bed for Flux-Compression-Generator Electroexplosive Opening Switches

Authors: David W. Belt; John J. Mankowski; Andreas A. Neuber; James C. Dickens; Magne Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4667677

Abstract: Helical flux compression generators (HFCGs) of a 50-mm form factor have been shown to produce output energies on the order of ten times the seeded value and a typical deposited energy of 3 kJ into a 3-muH inductor. One way to drive a high-power microwave source with an HFCG is by power conditioning, such as an inductive energy storage system (IESS). The output performance of the IESS is contingent upon the opening switch scheme, usually an electroexplosive fuse. Our previous work involving fuse parameter characterization has established a baseline for potential fuse performance. In order to optimize the electroexplosive wire fuse, we have constructed a nonexplosive test bed which simulates the HFCG output with high accuracy. We have designed and implemented a capacitor-based magnetic switching scheme to generate the near-exponential rise of the HFCG. The use of the nonexplosive HFCG test bed will allow the verification of scalability of the fuse parameter model and also allow testing of exotic fuse materials. The nonexplosive test bed has provided a more efficient method for electroexplosive switch development and has allowed us to expand the study of opening switches. We will also discuss the a priori calculated baseline fuse design and compare the experimental results of the gold-wire-material with the silver-wire-material baseline design. With the results presented, an accurate PSpice model applicable to our 45-kA HFCG systems will be available.

Journals

Window Flashover Initiation under Pulsed Microwave Excitation

Authors: J. Krile; G. Edmiston; J. Dickens; H. Krompholz; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4743719

Abstract: Surface flashover development at the output window of high power microwave (HPM) systems presents a major limitation to the power densities and pulse lengths transmitted through these interfaces. As a result, developing a physical model accurate in predicting surface flashover initiation is of prime interest. A Monte-Carlo type electron motion simulation has been developed to estimate the delay time from initial electron to flashover. Although this approach has shown reasonable agreement with experimental results, the process yielding the initial seed electron(s) was neglected in the model, primarily due to the lack of quantitative and qualitative information on seed electron production. For instance, computational efforts investigating seed electron production via collisional detachment from negative oxygen ions have shown that while effective at DC, the collisional detachment model cannot remain a likely contributor of electrons at high frequencies (Gt ~5 GHz). The key parameters impacting high power microwave surface flashover will be discussed and presented along with continued investigation into the statistics of possible seed electron sources, including trace contaminates present in the gas or on the dielectric surface.

Conferences

2007

A Bench Top Railgun With Distributed Energy Sources

Authors: J. Mankowski; J. Dickens; M. Giesselmann; B. McDaniel; B. McHale; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4033078

Abstract: Experimental results of a distributed energy source railgun are presented. Distributed energy source railguns were first proposed by Marshal in an asynchronous scheme and later by Parker synchronously. Both schemes employ a "traveling excitation wave" to push the projectile along the rail. The primary advantages of such a scheme over the common breech-fed is higher efficiency due to less energy remaining in the rail and lower rail resistive loses. Another advantage is the reduction in the probability of re-strike. However, these advantages are achieved at a cost of higher switching complexity. As a proof of principle experiment, we have constructed a bench-top solid armature railgun with distributed energy sources. Instead of a single, capacitive, breech-fed, energy source, the current is supplied by two storage capacitor banks, placed at different positions along the rail. The switching configuration, which requires a dedicated switch at each capacitor, is realized with sold state switches. The railgun is diagnosed in order to evaluate performance and to appropriately trigger the switches. In addition, experimental results are compared to simulation

IEEE Journals

A Synchronous Free-Running Arc Distributed Energy Railgun

Authors: R. W. Karhi; J. J. Mankowski; J. C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4346322

Abstract: Summary form only given. Experimental results utilizing a distributed energy scheme and free-running arc are presented. Analysis and observations of the issues associated with distributed energy switching of a plasma armature in the railgun will be explored. The use of a free running arc allows experiments to emulate a plasma armature railgun at high speeds (> 5 km/s) without the requirement of a large amount of stored energy. Diagnostics for this examination include rail and plasma current probes as well as independent Rogowski coils for each stage. The distributed system is comprised of four stages spaced uniformly along the rail length. Each stage contains a high voltage capacitor, an inductor, a phase controlled SCR, and a driver board for triggering. The high voltage capacitors used are capable of storing 50 kJ, but are typically charged to store less than 20 kJ. Fiber optic lines are integrated into the system to prevent misfire in the noisy EMI environment. Optimal switch timing is predicted by a computer simulation and tested for accuracy. The assembled railgun is 2.4 m long with a 1.7 cm times 1.7 cm bore cross section. The rails are made of machined UNS C11000 ETP copper. G-10 insulation contains the current probes and separates the Aluminum 6061-T6 outer support structure from the rails. Alumina ceramic inserts are secured by the G-10 and function to reduce in-bore ablation. A PVC chamber encloses the railgun and allows experiments to be conducted within the desired 1-10 torr environment. A plasma source at the breech reliably supplies plasma for each experimental test. The plasma injector is powered by a Marx generator to supply a 40 kV voltage and pulse length of 10 s. The coaxial injector is comprised of a tungsten rod, ceramic insulator, and stainless steel outer casing. Numerous experimental tests were conducted to investigate the dynamics of plasma armatures within a distributed energy source railgun. Variations of switch timing, bore pressure, current amplitude, and current pulse length within each stage have been tested. This data is analyzed to determine the effectiveness of a distributed energy system to suppress the plasma restrike phenomenon and increase plasma armature railgun performance.

IEEE Conferences

An asynchronous free-running arc, distributed energy railgun

Authors: R. Karhi; J. Mankowski; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4652541

Abstract: Experimental results comparing a breech-fed scheme and a distributed energy scheme for a free-running arc are presented. Analysis and observations of the issues associated with distributed energy switching of a plasma armature in the railgun will be explored. The use of a free running arc allows experiments to emulate a plasma armature railgun at high speeds (≫5km/s) without the requirement of a large amount of stored energy. Numerous experimental tests were conducted to investigate the dynamics of plasma armatures within a distributed energy source railgun. Variations of switch timing, bore pressure, current amplitude, and current pulse length within each stage have been tested. These data are analyzed to determine the effectiveness of a distributed energy system to suppress the plasma restrike phenomenon and increase plasma armature railgun performance.

IEEE Conferences

Contributing Factors to Window Flashover under Pulsed High Power Microwave Excitation at High Altitude

Authors: G. Edmiston; A. Neuber; L. McQuage; J. Krile; H. Krompholz; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4286507

Abstract: One of the major limiting factors for the transmission of high power microwave (HPM) radiation is the interface between dielectric-vacuum or even more severely between dielectric-air if HPM is to be radiated into the atmosphere. Surface flashover phenomena which occur at these transitions severely limit the power levels which can be transmitted. It is of major technological importance to predict surface flashover events for a given window geometry, material and power level. When considering an aircraft based high power microwave platform, the effects on flashover formation due to variances in the operational environment corresponding to altitudes from sea level to 50,000 feet (760 to 90 Torr; 1 Torr=133.3 Pa) are of primary interest. The test setup is carefully designed to study the influence of each atmospheric variable without the influence of high field enhancement or electron injecting metallic electrodes. Experimental data of flashover delay times across different materials, such as polycarbonate, Teflonreg, and high density polyethylene as a function of background pressure and gas type, air, N2, argon are discussed. An empirical relationship between flashover field amplitude and delay time is given.

Journals

Development of an Ultra-Compact Explosively Driven Magnetic Flux Compression Generator System

Authors: J. T. Krile; S. L. Holt; D. J. Hemmert; J. W. Walter; J. C. Dickens; L. L. Altgilbers; A. H. Stults

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4346027

Abstract: Summary form only given. Explosively driven magnetic flux compression generators (MFCG) are effective high current, compact, disposable pulsed power supplies. A common type of MFCG in use is a helical generator because it can provide very high current gain in a compact form. Successful implementation of a MFCG as a pulsed power source requires several peripheral systems including a seed current source and a high current switching mechanism. Additionally, for driving higher impedance loads, a power conditioning system is required to convert the high current, low voltage MFCG output into a more suitable voltage. HEM Technologies' currently developed system utilizes an ultra compact, seed source previously developed by HEM Technologies. An explosively driven closing switch provides both the switching action and acts as a delay generator to allow for the current rise in the MFCG. The output of the MFCG is conditioned via an exploding fuse wire and spark gap pair to convert the high current output to high voltage. HEM Technologies has performed extensive modification and testing of the end-to-end system. The current and energy conversion will be presented along with typical output voltages using different fusing techniques.

IEEE Conferences

Electrical and Optical Measurements of Explosively Driven Plasma Jets

Authors: J. Walter; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4346029

Abstract: Summary form only given. Electrical and optical measurements were performed on explosively driven plasma jets. The explosive devices are in the form of a conical shaped charge. The electrical diagnostic consisted of measuring the current passed through a jet when it made a connection between two metal plates. An energy storage capacitor connected to the two plates was charged to between 350 V and 10 kV, and then discharged through the jet. Also, an ICCD camera was used to capture high-speed single frame pictures of the propagating jet. Several shots were fired with variations in the capacitor voltage, the plate geometry, and the jet material. Current waveforms and optical images are presented. All experiments were performed in the explosive and high power RF experimental facility at the Center for Pulsed Power and Power Electronics at Texas Tech University.

IEEE Conferences

Electro-Explosive Fuse Optimization for Helical Flux Compression Generator using a Non-Explosive Test Bed

Authors: D. McCauley; D. Belt; J. Mankowski; J. Dickens; A. Neuber; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4345962

Abstract: Helical Flux Compression Generators (HFCG) of 50 mm form factor have been shown to produce a maximum energy deposit of 3 kJ into a 3 muH inductor from a seed current. A large dl/dt into a coupled load is possible when an electro-explosive fuse is used. Previous work with a non-optimized fuse has produced ~100 kV into a 15Omega load which leads into a regime relevant for High Power Microwave (HPM) systems. It is expected that ~3()0kV can be achieved with the present 2 stage HFCG driving an inductive storage system with an electro-exploding fuse. In order to optimize the electro-explosive fuse design, a non-explosive test bed, which closely simulates the 45 kA HFCG output, is used. To optimize the tiise, effects of fuse material, fuse length, and fuse shape will be examined as well as the effects of various quenching materials. Our previous work has characterized fuse material but we are also looking into the effects of the processes used to create the fuse wire, such as tempered wire versus fully annealed wire. Additionally, to maximize the output voltage and minimize the fuse recovery time, we are optimizing the length of the fuse wire. For shorter fuse lengths, we are optimizing fuse shape as well as fuse length to find the best fuse recovery time. By optimizing the individual parameters of an electro-explosive fuse, the fuse as a whole will be optimized to produce maximum output voltage when used with an HFCG.

Conferences

Electro-Explosive Switches For Helical Flux Compression Generators

Authors: Bell, D; Mankowski, J; Neuber, A; Dickens, J; Kristiansen, M

PDF: https://ieeexplore.ieee.org/document/4530702

Abstract: Helical Flux Compression Generators coupled with an inductive energy storage system have shown promising results as a driving source for High Power Microwave (HPM) loads. The output performance of the inductive energy storage system is contingent upon the opening switch scheme, usually an electro-explosive fuse. Our previous work involving fuse parameter characterization has established a baseline for potential fuse performance. By applying this fuse characterization model to an HFCG powered system, a non-optimized fuse has produced 60 kV into an HPM equivalent load with an HFCG output of 15 kA into a 3 mu H inductor. Utilization of a non-explosive HFCG test-bed has produced 36 kV into an HPM equivalent load with an output of 15 kA into a 1.3 mu H inductor. The use of a non-explosive HFCG test bed will allow the verification of scalability of the fuse parameter model and also allow testing of exotic fuse materials. Prior analysis of fuse parameters has been accomplished with various materials including Silver (Au), Copper (Cu), and Aluminum (Al), but particular interest resides in the use of Gold (Ag) fuse material. We will discuss the a-priori calculated baseline fuse design and compare the experimental results of the gold wire material with the silver wire material baseline design. With the results presented, an accurate Pspice model applicable to our 45 kA HFCG systems will be available and allow the development of accurate modeling for higher current systems.

Conference Paper/Presentation

Electro-explosive fuse optimization for Helical Flux compression generator using a non-explosive test bed

Authors: D. McCauley; D. Belt; J. Mankowski; J. Dickens; A. Neuber; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4652362

Abstract: Helical Flux Compression Generators (HFCG) of 50 mm form factor have been shown to produce a maximum energy deposit of 3 kJ into a 3 μH inductor from a seed current. A large dI/dt into a coupled load is possible when an electro-explosive fuse is used. Previous work with a non-optimized fuse has produced ∼100 kV into a 15 Ω load which leads into a regime relevant for High Power Microwave (HPM) systems. It is expected that ∼300 kV can be achieved with the present 2 stage HFCG driving an inductive storage system with an electro-exploding fuse. In order to optimize the electro-explosive fuse design, a non-explosive test bed, which closely simulates the 45 kA HFCG output, is used. To optimize the fuse, effects of fuse material, fuse length, and fuse shape will be examined as well as the effects of various quenching materials. Additionally, to maximize the output voltage and minimize the fuse recovery time, we are optimizing the length of the fuse wire. For shorter fuse lengths, we are optimizing fuse shape as well as fuse length to find the best fuse recovery time. By optimizing the individual parameters of an electro-explosive fuse, the fuse as a whole will be optimized to produce maximum output voltage when used with an HFCG.

Conferences

Evaluation of switch jitter in a high pressure coaxial spark gap

Authors: C. James; J. Dickens; S. Holt; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4651906

Abstract: The design and jitter performance of a high-pressure, coaxial spark gap, triggered by field distortion by a center plane electrode is presented. Additional comparisons with trigatron style triggering are also presented. The switch was tested up to 100 pulses per second (pps) with a maximum switching voltage of 50 kV in nitrogen. Analysis will focus on jitter measurements taken over the full lifetime of the switch. This paper presents the results of this analysis. Specifically, switch jitter and lifetime will be evaluated as a function of switch geometry as a whole and as a function of trigger electrode geometry.

Conferences

Explosive opening switch utilizing shockwave induced conduction in PMMA and PVC

Authors: C. Lynnx; A. Neuber; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4651971

Abstract: It is known that PMMA and PVC become conductive under shock compression. However, to develop an opening switch, the material’s recovery from conductor back to insulator is critical. Heating must be minimized in order to optimize recovery. Two sources of heat in this switch include shock induced heating and switch loss heating, which should be balanced for optimal results. Furthermore, it is also important to determine if the observed switching behavior is due to shock unloading or intrinsic material relaxation properties. In the extreme case of recovery, bulk breakdown may become an issue. This paper presents experimental data and discusses initial results as they relate to the development of an opening switch.

Conferences

Interface Breakdown During High-Power Microwave Transmission

Authors: A. A. Neuber; G. F. Edmiston; J. T. Krile; H. Krompholz; J. C. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4033091

Abstract: The major limiting factor in the transmission of narrowband high-power microwaves (HPM) has been the interface between vacuum-vacuum or even more severely between vacuum-air if HPM are to be radiated into the atmosphere. Extensive studies have identified the physical mechanisms associated with vacuum/dielectric flashover, as opposed to the mechanisms associated with dielectric/air flashover, which are not as well known. Due to the high electron collision frequencies (in the terahertz range) with the background gas molecules, established mitigation methods and concepts of vacuum/dielectric flashover will have to be re-evaluated. The primarily limiting factors of HPM transmission through a dielectric/air interface are presented based on recent experiments at 2.85 GHz. The physics of the involved mechanisms and their practical ramifications are discussed. The potential of surface roughness/geometry for flashover mitigation is addressed as well

IEEE Journals

Jitter and Recovery Rate of a Triggered Spark Gap with High Pressure Gas Mixtures

Authors: Yeong-Jer Chen; John J. Mankowski; John W. Walter; James C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4345561

Abstract: Summary form only given. Recent attention in impulse antenna phased array has necessitated the need to develop a reliable high voltage, high repetition rate switch that will operate with ultra low jitter. An ideal jitter of a small fraction of the rise time is required to accurately synchronize the array to steer and preserve the rise time of the radiated pulse. This paper presents the impact, gases and gas mixtures have on switch performance which includes recovery rate and in particular, jitter. A 50 Omega, 2.4 nF pulse forming line is charged to 50 kV and provides the low inductance voltage source to test the different gases. Triggering is provided by an SOS voltage source that supplies >100 kV, 10 ns rise-time pulses at a rep rate up to 1 kHz in burst mode. A hermetically sealed spark gap with a Kel-F lining is used to house the switch and high pressure gas. The system will also introduce a high pressure gas mixing chamber that can mix various gases up to 2000 psi. Gases tested include dry air, H2, and SF6.

Conferences

Jitter and recovery rate of a triggered spark gap with high pressure gas mixtures

Authors: Yeong-Jer Chen; John J. Mankowski; John W. Walter; James C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4651833

Abstract: Recent attention to impulse antenna phased arrays has necessitated the need to develop a reliable high voltage, high repetition rate switch that will operate with ultra low jitter. The ideal jitter of such a switch would be a small fraction of the risetime in order to synchronize the array to steer and preserve the risetime of the radiated pulse. This paper presents the impact, gases and gas mixtures have on switch performance which includes recovery rate and in particular, jitter. A 50 Ω, 1 nF pulse forming line is charged to 30 kV and provides the low inductance voltage source to test the different gases. Triggering is provided by an SOS voltage source that supplies ≫100 kV, 10 ns risetime pulses at a rep rate up to 1 kHz in burst mode. A hermetically sealed spark gap with a Kel-F lining is used to house the switch and high pressure gas. The system contains a high pressure gas mixing chamber that can mix various gases up to 2000 psi. Gases tested include dry air, H2, N2, and SF6.

Conferences

Modeling of a Single Element Pulsed Ring-Down Antenna for Implementation in a Phased Array System

Authors: D. Belt; J. Walter; J. Mankowski; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4346122

Abstract: Summary form only given. A pulsed ring-down phased array antenna provides substantial energy deposition in the far field region in addition to a broad range main beam with scanning capabilities. This allows remote neutralization of Improvised explosive devices (IEDs) at far field distances and in virtually any direction. The pulsed ring-down antenna operates by charging the single element antenna with a high potential source and closing a switch to develop transient wave reflections on the antenna which then propagate in air. The performance of a pulsed ring-down phased arrav is highly contingent upon the design and performance of the individual antenna elements within the array. Such factors as operating voltage, antenna capacitance, material losses, antenna geometry and closing switch conductance characteristics must be examined for optimal performance to be achieved. By utilizing the Comsol RF module transient analysis functions, we are able to characterize the various parameters beginning with a monopole and a dipole pulsed ring-down antenna operating in the hundreds of MHz range. We have examined and compared the results achieved from the experimental setup to the simulation model in order to better characterize the individual components of the antenna. We have also examined the discrepancies between an ideal closing switch and the experimental setup closing switch, which dramatically affects the far field range of the antenna. We have examined the material properties of the antenna to improve losses and increase system capacitance allowing an increase in the number of RF cycles per antenna discharge. With the results presented, an accurate model of pulsed ring-down antennas is available and will allow future development of more complex geometries that will improve the operation of pulsed ring- down phased array.

Conferences

Modeling of a single element pulsed ring-down antenna for implementation in a phased array system

Authors: D. Belt; J. Mankowski; J. Walter; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4652443

Abstract: A pulsed ring-down phased array antenna provides substantial energy deposition in the far field region in addition to a broad range main beam with scanning capabilities. This allows remote neutralization of Improvised Explosive Devices (IEDs) at far field distances and in virtually any direction. The pulsed ring-down antenna operates by charging the single element antenna with a high potential source and closing a switch to develop transient wave reflections on the antenna which then propagate in air. The performance of a pulsed ring-down phased array is highly contingent upon the design and performance of the individual antenna elements within the array. Such factors as operating voltage, antenna capacitance, material losses, antenna geometry and closing switch conductance characteristics must be examined for optimal performance to be achieved. By utilizing the COMSOL RF module transient analysis functions, we are able to characterize the various parameters beginning with a monopole and a dipole pulsed ring-down antenna operating in the hundreds of MHz range. We have examined and compared the results achieved from the experimental setup to the simulation model in order to better characterize the individual components of the antenna. We have also examined the discrepancies between an ideal closing switch and the experimental setup closing switch, which dramatically affects the far field range of the antenna. We have examined the material properties of the antenna to improve losses and increase system capacitance allowing an increase in the number of RF cycles per antenna discharge. With the results presented, an accurate model of pulsed ring-down antennas is available and will allow future development of more complex geometries that will improve the operation of pulsed ring-down phased array.

Conferences

Opening Switch Utilizing Shock Wave Induced Conduction in PMMA and PVC

Authors: C. Lynn; A. Neuber; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4345862

Abstract: Summary form only given. The feasibility of utilizing shock loaded and unloaded dielectrics as a true closing/opening switch as part of an explosive-driven pulse power system is addressed. While it is known that shock wave compressed PVC and PMMA become conductive, the details of the material's recovery from the conducting back to the insulating state are much less known. To be effective as an opening switch, the recovery time has to be minimized, i.e., for instance, heating of the material must be minimized. The two primary sources of heat in the switch are shock induced heating and switch loss heating. These sources must be balanced for optimal results. Furthermore, it is also important to determine if the observed temporal behavior is due to finite shock unloading or intrinsic material relaxation properties. In the extreme case, bulk breakdown may occur during recovery as voltage increases across the switch. Previous work, performed primarily with a C-4 packed compression rod, has achieved a switch on-state resistance of less than 1 ohm, with an average on-state duration of 80 microseconds. It was also shown that PMMA appears to have a much sharper transition time than PVC, between both insulator to conductor, and conductor to insulator. The results presented here use a timed explosion to more carefully control the intensity and duration of the shock wave. This allows for more control over shock induced heating of the sample. We will present recent experimental data and discuss results as they relate to the development of an opening switch.

IEEE Conferences

Small Back-Lighted Thyratrons

Authors: H. Chen; C. Jiang; A. Kuthi; M. A. Gundersen; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4345736

Abstract: Summary form only given. We report studies of mini (6.3 mm diameter electrodes) back-lighted thyratron (BLT) switches, operating with currents up to 10 kA, and hold off voltages in excess of 40 kV for the mini-BLT. The pseudospark is a thyratron with a cathode variant: the cathode emission is provided by an initially hollow cathode mode that transitions to a self-heated super-emissive mode. As a result of this mechanism, the pseudospark does not require externally supplied power for heating the cathode. The BLT is an optically-triggered version of this switch. The switch studies reported here are of (optically triggered) BLTs with helium or hydrogen fill. Hold-off voltage and optical triggering studies of these small switches suggest that they can be optimized for miniaturized high voltage pulse generation. Overvolted operation was also studied for potential applications such as implementation into Marx generators. These studies suggest that the small pseudospark BLT represents progress towards ultra compact high peak power switches for compact repetitive pulsed power applications. Research to develop sealed versions will be reported, and a new plasma source based from the BLT structure will also be discussed.

IEEE Conferences

Testing of new ferroelectric elements custom engineered for explosively driven ferroelectric applications

Authors: S. L. Holt; J. T. Krile; D. J. Hemmert; W. S. Hackenberger; E. F. Alberta; J. W. Walter; J. C. Dickens; L. L. Altgilbers; A. H. Stults

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4652397

Abstract: Explosively driven ferroelectric generators (FEGs) are reliable, compact, high voltage sources that utilize high pressures to liberate charge trapped in the crystal structure of ferroelectric materials. For the active ferroelectric element most FEG designs use commercial lead zirconate-titanate (PZT) compositions designed for either precision actuators or naval sonar transducers. However, the material properties that are important in FEG applications are not the same material properties for which these materials have been designed to maximize. FEG designs utilizing these commercial materials are performance limited by high voltage breakdown, mechanical failure and low energy densities. TRS Technologies inc. has produced a new series of ferroelectric elements designed specifically for FEG applications. HEM Technologies has performed dielectric strength and shock compression experiments on these new materials to evaluate their performance in comparison to existing commercially available materials.

Conferences

Theoretical Pulsed Ring Down Antenna Array Performance

Authors: J. Walter; J. Dickens; J. Mankowski; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4345788

Abstract: Summary form only given. High-power transient RF transmitters are currently being developed for multiple applications. One potential high- power pulsed source being considered is the pulsed ring- down source (PRDS). In a typical PRDS, electrical energy that is stored in the device structure is discharged through a switch, generating a damped ringing radiated waveform. The magnitude of the transmitted field is limited by parameters such as the overall device geometry and switch characteristics. The potential exists to increase the radiated far field power density by utilizing an array of PRDS transmitters. The performance of such an array depends on the triggering jitter of the device switches and the design of the individual radiating elements. The application of the array concept to pulsed ring-down sources using gas spark gap switches is examined. Theoretical array performance is discussed, taking into account practical switch jitter distributions, practical switch triggering schemes, and individual element characteristics.

Conferences

Theoretical pulsed ring down antenna array performance

Authors: J. Walter; J. Dickens; J. Mankowski; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4651932

Abstract: High-power transient RF transmitters are currently being developed for multiple applications. One potential high-power pulsed source being considered is the pulsed ring-down source (PRDS). In a typical PRDS, electrical energy that is stored in the device structure is discharged through a switch, generating a damped ringing radiated waveform. The magnitude of the transmitted field is limited by parameters such as the overall device geometry and switch characteristics. The potential exists to increase the radiated far field power density by utilizing an array of PRDS transmitters. The performance of such an array depends on the triggering jitter of the device switches and the design of the individual radiating elements. The application of the array concept to pulsed ring-down sources using gas spark gap switches is examined. Theoretical array performance is discussed, taking into account practical switch jitter distributions.

Conferences

2006

A Flux Compression Generator Non-Explosive Test Bed for Explosive Opening Switches

Authors: D. Belt; J. Mankowski; A. Neuber; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4216234

Abstract: Helical flux compression generators (HFCG) of a 50 mm form factor have been shown to produce output energies on the order of ten times the seeded value and a typical deposited energy of 3 kJ into a 3 muH inductor. Our previous work with a non-optimized fuse has produced-100 kV into a 15 load, which leads into a regime relevant for high power microwave (HPM) systems. It is expected that-300 kV can be achieved with the present 2-stage HFCG driving an inductive storage system with electro-exploding fuse. In order to optimize the electro-explosive wire fuse, we have constructed a non-explosive test bed which simulates the HFCG output with high accuracy. We have designed and implemented a capacitor based, magnetic switching scheme to generate the near exponential rise of the HFCG. The varying inductance approach utilizes 4 stages of inductance change and is based upon a piecewise linear regression model of the HFCG waveform. The non-explosive test bed will provide a more efficient method of component testing and has demonstrated positive initial fuse results

Conferences

Characterization Of Explosively Driven Ferroelectric Generator Material

Authors: S. L. Holt; D. J. Hemmert; J. W. Walter; J. J. Mankowski; J. C. Dickens; M. Kristiansen; L. L. Altgilbers

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4530693

Abstract: Explosively driven ferroelectric generators (FEGs) are reliable, compact, high voltage sources for driving ultra-compact high power devices. When energized by mechanical stress, they release charge from their crystal structure, acting similar to a charged high voltage capacitor. However, due to the relatively low energy of these devices, they must be well matched to their application so that the full potential of the material can be utilized. This requires proper characterization of the material's electrical output as a function of the input shockwave. HEM Technologies and Texas Tech University characterized a ferroelectric ceramic, EDO EC-64, for different pressures to determine possible loss mechanisms and its maximum output power and energy.

Conference Paper/Presentation

Conduction and breakdown mechanismsin transformer oil

Authors: M. Butcher; A. A. Neuber; M. D. Cevallos; J. C. Dickens; H. Krompholz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1621332

Abstract: With a fast coaxial test setup using high speed electrical and optical diagnostics, prebreakdown current pulses and shadowgraphy images are measured for direct current (dc) breakdown in Univolt 61 transformer oil. Also, dc currents across the gap are measured using a high sensitivity electrometer. The conduction and breakdown mechanisms in transformer oil as function of applied hydrostatic pressures are quantified. Together, this information provides data on the development of current flow in the system. We have identified three stages in the conduction process prior to breakdown for highly nonuniform fields. Stage 1 is characterized by a resistive current at low fields. Increasing the applied electric field lowers the effective barrier at the metal/dielectric interface allowing a "tunneling" mechanism to begin, leading to the rapid rise in the injection current observed in stage 2. In stage 3, at high fields, the current reaches space charge saturation with an apparent mobility of 3/spl middot/10/sup -3/ cm/sup 2//V/spl middot/s prior to breakdown. The processes of final breakdown show a distinct polarity dependence. A strong pressure dependence of the breakdown voltage is recorded for negative needle/plane breakdown; a 50% reduction in breakdown voltage is observed when the hydrostatic pressure is lowered from atmospheric pressure to hundreds of mtorr. Positive needle discharges show a reduction of only about 10% in breakdown voltage for the reduced pressure case. Weak pressure dependence indicates the breakdown mechanism does not have a strong gaseous component. We will discuss possible links between conduction current and dc breakdown.

IEEE Journals

Contributing Factors to Window Flashover Under Pulsed High Power Microwave Excitation at High Altitude

Authors: G. Edmiston; A. Neuber; J. Krile; L. McQuage; H. Krompholz; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4216218

Abstract: One of the major limiting factors for the transmission of high power microwave (HPM) radiation is the interface between dielectric-vacuum, or even more severely, between dielectric-air if HPM is to be radiated into the atmosphere. Surface flashover phenomena which occur at these transitions severely limit the power levels which can be transmitted. It is of major technical importance to predict surface flashover events for a given window geometry, material and power level. When considering an aircraft based high power microwave platform, the effects on flashover formation due to variances in the operational environment corresponding to altitudes from sea level to 50,000 feet (760 Torr to 90 Torr) are of primary interest. The test setup is carefully designed to study the influence of each atmospheric variable without the influence of high field enhancement or electron injecting metallic electrodes.

IEEE Conferences

Design And Implementation Of A Flux Compression Generator Nonexplosive Test Bed For Electroexplosive Fuses

Authors: Belt, D; Mankowski, J; Neuber, A; Dickens, J; Kristiansen, M

PDF: https://aip.scitation.org/doi/10.1063/1.2336757

Abstract: Helical flux compression generators (HFCGs) of a 50 mm form factor have been shown to produce output energies on the order of ten times the seeded value and a typical deposited energy of 3 kJ into a 3 mu H inductor. By utilizing an electroexplosive fuse, a large dI/dt into a coupled load is possible. Our previous work with a nonoptimized fuse has produced similar to 100 kV into a 15 Omega load, which leads into a regime relevant for high power microwave systems. It is expected that similar to 300 kV can be achieved with the present two-stage HFCG driving an inductive storage system with electroexploding fuse. In order to optimize the electroexplosive wire fuse, we have constructed a nonexplosive test bed which simulates the HFCG output with high accuracy. We have designed and implemented a capacitor based, magnetic switching scheme to generate the near exponential rise of the HFCG. The varying inductance approach utilizes four stages of inductance change and is based upon a piecewise linear regression model of the HFCG wave form. The nonexplosive test bed will provide a more efficient method of component testing and has demonstrated positive initial fuse results. By utilizing the nonexplosive test bed, we hope to reduce the physical size of the inductive energy storage system and fuse substantially. (c) 2006 American Institute of Physics.

Journal

Electro-Explosive Switches for Helical Flux Compression Generators

Authors: D. Belt; J. Mankowski; A. Neuber; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4530702

Abstract: Helical Flux Compression Generators coupled with an inductive energy storage system have shown promising results as a driving source for High Power Microwave (HPM) loads. The output performance of the inductive energy storage system is contingent upon the opening switch scheme, usually an electro-explosive fuse. Our previous work involving fuse parameter characterization has established a baseline for potential fuse performance. By applying this fuse characterization model to an HFCG powered system, a non-optimized fuse has produced 60 kV into an HPM equivalent load with an HFCG output of 15 kA into a 3 μH inductor. Utilization of a non-explosive HFCG test-bed has produced 36 kV into an HPM equivalent load with an output of 15 kA into a 1.3 μH inductor. The use of a non-explosive HFCG test bed will allow the verification of scalability of the fuse parameter model and also allow testing of exotic fuse materials. Prior analysis of fuse parameters has been accomplished with various materials including Silver (Au), Copper (Cu), and Aluminum (Al), but particular interest resides in the use of Gold (Ag) fuse material. We will discuss the a-priori calculated baseline fuse design and compare the experimental results of the gold wire material with the silver wire material baseline design. With the results presented, an accurate Pspice model applicable to our 45 kA HFCG systems will be available and allow the development of accurate modeling for higher current systems.

Conferences

High-Power Microwave Surface Flashover of a Gas–Dielectric Interface at 90–760 torr

Authors: G. Edmiston; J. Krile; A. Neuber; J. Dickens; H. Krompholz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1710041

Abstract: The major limiting factor in the transmission of high-power microwave (HPM) has been the interface between dielectric-vacuum or, even more severely, between dielectric-air, if HPM is to be radiated into the atmosphere. Extensive studies have identified the physical mechanisms associated with vacuum-dielectric flashover, as opposed to the mechanisms associated with air-dielectric flashover, which are not as well known. Surface-flashover tests involving high field enhancement due to the presence of a triple point have shown that volume breakdown threshold (dielectric removed) is approximately 50% higher than the flashover threshold with a dielectric interface over the 90-760 torr range. In order to quantify the role of field enhancement in the flashover process independent of electron injection from metallic surfaces, the effects of the triple point are minimized by carefully choosing the geometry, and in some cases, the triple point is "removed" from the flashover location. Experimental results were presented, including the impact of gas pressure and the presence of UV illumination, along with temperature analysis of the developing discharge plasma and temporally resolved images of the flashover formation. These results are compared with literature data for volume breakdown in air, with discussion on the similarities and differences between the data

IEEE Journals

Pressure Induced Conductivity For High Power Switching

Authors: H. Veselka; A. Neuber; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4216173

Abstract: Summary form only given. Investigations of shock induced conductivity of non-crystalline insulators and crystalline semiconductors were performed. Although we measured the insulator-to-metallic state transition time and conductivity, the focus of this investigation was on the recovery phase of the induced conductivity (i.e. metallic-to-insulator state transition). The recovery time and shock conditions were measured with high speed electrical diagnostics. The goal of this research is to determine the feasibility of using shock induced conductivity as a means of producing a high power opening switch. To minimize switch losses, the insulator-to-metallic transition time and conductance is also important, but has been more widely studied. Initial impact studies have shown that certain insulator can be conductive for 100 microseconds and recover under modest voltage less than one microsecond using a ten gram explosive charge. Various shock intensities are used in the study. The shock is produced primarily with conventional commercial explosives. In addition, the impact of sample thickness and compression duration on the induced the conductivity were also studied. The correlation between modest voltage and high voltage recovery time and shut-off current were studied

Conference Paper/Presentation

Pulsed Unipolar Surface Flashover at Atmospheric Conditions

Authors: K. Morales; J. Krile; A. Neuber; H. Krompholz; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4216162

Abstract: Dielectric surface flashover along insulators in vacuum has been comprehensively researched over the years. However, the primary mechanisms involved in dielectric flashover at atmospheric pressures have yet to be as extensively analyzed with variable parameters such as electrode geometry, background gas, humidity, and temporal characteristics of the applied voltage. Understanding the fundamental physical mechanisms involved in surface flashover at atmospheric pressures is vital to characterizing and modeling the arc behavior. Previous DC and unipolar excitation experiments have shown distinct arc behavior in air and nitrogen environments for an electrode geometry that produces electric field lines that curve above the dielectric surface. Specifically, flashover arcs in an air environment were observed to develop along the dielectric surface. Experiments conducted in nitrogen revealed that the arc developed along the electric field lines, above the surface of the dielectric. It was also of importance to alter the temporal characteristics of the applied voltage to simulate lightning situations and investigate the impact on the arc behavior and voltage delay times. A solid state high voltage pulser with an adjustable pulse width of ~500 ns at FWHM and amplitudes in excess of 30 kV was specifically developed to replicate the temporal characteristics of a voltage pulse observed when a building structure is hit by a lightning strike. Based on these results, the physical mechanisms primarily involved in pulsed unipolar surface flashover will be discussed. Additional studies regarding the effects of humidity and surface roughness on the flashover arc behavior will also be presented

IEEE Conferences

The Impact of Field Enhancements and Charge Injection on the Pulsed Breakdown Strength of Water

Authors: D. A. Wetz; J. J. Mankowski; J. C. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1710025

Abstract: A unique theoretical model of the breakdown mechanism in water has been developed and further tested in both simulation software and experimentation. The conducted experiments test the degree to which electrode material, surface roughness, and surface area impact the dielectric strength of water. Voltage pulses with respective rise times of roughly 200 and 20 ns were applied to a water test gap producing electric fields in excess of 1.5 MV/cm. In experiments testing various electrode materials, thin film coatings of various metallic alloys and oxides were applied to Bruce-profiled stainless steel electrodes, with an effective area of 5 cm2, through ion beam deposition. Similar Bruceprofiled stainless steel electrodes with surface roughness ranging from 0.26 to 1.96 mum and effective areas ranging from 0.5 to 75 cm2 were used in the study of surface roughness and area. Additionally, shadowgraph images of a point plane geometry were taken to further understand the breakdown processes that occur

IEEE Journals

The Impact of Water Conductivity, Electrode Material, and Electrode Surface Roughness on the Pulsed Breakdown Strength of Water

Authors: D. Wetz; J. Mankowski; D. McCauley; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4216144

Abstract: Experimental results are presented on the impact water conductivity, electrode material, and electrode surface roughness have on the dielectric strength of water. A 2 mm water gap was tested under pulsed conditions with maximum electric fields in excess of 1.5 MV/cm. Bruce profiled electrodes manufactured from various materials including molybdenum, aluminum, copper, tungsten, nickel, stainless steel, and zinc oxide, which have work functions ranging from 4.2 eV to 5.3 eV, have been tested. The roughness average of the various surfaces was varied from 0.1 mum to 1.96 mum and the conductivity of the water within the gap was varied from 1muS/cm to 39 muS/cm to determine the impact each has when tested in combination with the various electrode materials and surface roughnesses. Conclusions are made as to the effect each of these factors has on the holdoff strength of a water dielectric system

Conferences

2005

A Compact, Repetitive, 500kV, 500 J, Marx Generator

Authors: A. A. Neuber; Y. J. Chen; J. C. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4084440

Abstract: The electrical characteristics and design features of a low inductance, compact, 500 kV, 500 J, 10 Hz repetition rate, Marx generator are discussed. While benefiting from the large energy density of mica capacitors, 4 mica capacitors were utilized in parallel per stage, keeping the parasitic inductance per stage low. Including the spark- gap switches, a stage inductance of 55 nH was measured, which translates with 100 nF capacitance per stage to ~18.5 Omega characteristic Marx impedance. Using solely inductors, ~1 mH each, as charging elements instead of resistors enabled charging the Marx within less than 100 ms with little charging losses. The pulse width of the Marx into a matched resistive load is about 200 ns with 50 ns rise-time. Repetitive HPM generation with the Marx directly driving a small Vircator has been verified. The Marx is fitted into a tube with 30 cm diameter and a total length of 0.7 m. We discuss the Marx operation at up to 21 kV charging voltage per stage, with repetition rates of up to 10 Hz in burst mode primarily into resistive loads. A lumped circuit description of the Marx is also given, closely matching the experimental results.

IEEE Conferences

A Low-Cost Metallic Cathode for a Vircator HPM Source

Authors: J. Mankowski; Y. Chen; J. Dickens; A. Neuber; R. Gale

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4084154

Abstract: Recent research efforts at TTU include the testing of a rapidly charged, rep-rated Marx generator driving a reflex triode vircator [1]. As expected, the burning of the cathode material (ordinary cloth velvet), was the primary failure mechanism during repetitive operation. In an effort to achieve a repetitive vircator (>10 Hz), we are exploring a low-cost, all-metal cathode. The cathode is made from aluminum with a patterned surface. A typical pattern is composed of peaks and troughs with dimensions on the order of tens of microns. The pattern is achieved with a simple, low-cost chemical etching process. Results include current, voltage, and microwave waveforms from two solid metal cathodes and a cloth velvet cathode.

IEEE Conferences

Broadband Characterization of Transient Antennas

Authors: J. Walter; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4084153

Abstract: The application of pulsed power to transient RF/microwave generation for warhead/projectile payloads is currently a significant research area. In this application, traditional fixed antenna designs have two major drawbacks: the size required for efficient radiation can be prohibitive for frequencies much less than 1 GHz, and the fixed antenna can make the device vulnerable to electromagnetic counterattack. One frequently proposed solution to both issues is the use of transient antennas. To effectively integrate these devices, the various types of transient antennas must be characterized over a wide frequency band during their transient formation period. A testing method being developed at the Center for Pulsed Power and Power Electronics at Texas Tech University utilizing a broadband transmitter and receiver is described.

IEEE Conferences

Bubble Dynamics and Channel Formation for Cathode Initiated Discharges in Transformer Oil

Authors: M. Cevallos; M. Butcher; J. Dickens; A. Neuber; H. Krompholz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4084448

Abstract: The development of cathode initiated low density channel formation and propagation leading to self breakdown in transformer oil is investigated using high speed electrical and optical diagnostics in a coaxial system with a point/plane axial discharge at various hydrostatic pressures. A cathode initiated channel formation and propagation model based upon single bubble dynamics has been presented by Kattan [1]. Experiments based on high-speed shadowgraphy were conducted to decide if the principles that govern single bubble dynamics could be applied to cathode initiated channel formation. These experiments show bubble motion away from the cathode, with separation velocities on the order of 10's m/s. This separation is similar for single bubbles generated at the cathode and for bubble chains developing into low-density channels. Lifetimes of these channels are recorded and show good correlation with the Rayleigh model [2] used to predict lifetimes of single bubbles. Experiments at reduced hydrostatic pressure reveal a critical pressure below which low density channel expansion occurs, further corroborating the presence of a gas phase. Finally, the pressure dependence of the breakdown voltage due to the expansion of the low density channels is examined and a model for this dependence is presented. The experiments conducted confirm the presence of a gas phase channel, its correlation with single bubble dynamics, and its importance to final breakdown.

IEEE Conferences

Composite Shadowgraphy and Luminosity Images of Self Breakdown Discharge Channels in Transformer Oil

Authors: M. Cevallos; M. Butcher; J. Dickens; A. Neuber; H. Krompholz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4084384

Abstract: The physics of cathode initiated discharge formation leading to self breakdown in transformer oil is investigated using high speed electrical and optical diagnostics in a coaxial system with a point/plane axial discharge. Previous research conducted on self breakdown channel formation using high speed shadowgraphy and photography of the emitted light has shown tree-like structures for both cathode and anode initiated discharges, with characteristic differences. Cathode initiated discharges expand faster to a more "bushy" appearance, whereas anode initiated discharges show branching localized channels. So far, the spatial resolution to detect small luminous areas in pre- breakdown discharges and to determine their correlation to low density regions visible in the shadowgraphs was not sufficient in the experiments described in this paper, thus a systematic variation of exposure times, and time delays between luminosity pictures and shadowgraphy pictures has been performed. These experiments confirm that the luminosity emitted during prebreakdown events is generated from the low density regions seen in the shadowgraphy images, indicating charge amplification mechanisms in the gas phase for cathode initiated events. This statement is further supported by the dependence of both the channel dynamics and the light emission at lowered hydrostatic pressure.

IEEE Conferences

Design And Optimization Of A Compact, Repetitive, High-Power Microwave System

Authors: Chen, YJ; Neuber, AA; Mankowski, J; Dickens, JC; Kristiansen, M; Gale, R

PDF: https://aip.scitation.org/doi/10.1063/1.2093768

Abstract: The electrical characteristics and design features of a low inductance, compact, 500 kV, 500 J, 10 Hz repetition rate Marx generator for driving an high-power microwave (HPM) source are discussed. Benefiting from the large energy density of mica capacitors, four mica capacitors were utilized in parallel per stage, keeping the parasitic inductance per stage low. Including the spark-gap switches, a stage inductance of 55 nH was measured, which translates with 100 nF capacitance per stage to similar to 18.5 Omega characteristic Marx impedance. Using solely inductors, similar to 1 mH each, as charging elements instead of resistors enabled charging the Marx within less than 100 ms with little charging losses. The pulse width of the Marx into a matched resistive load is about 200 ns with 50 ns rise time. Repetitive HPM generation with the Marx directly driving a small virtual cathode oscilator (Vircator) has been verified. The Marx is fitted into a tube with 30 cm diameter and a total length of 0.7 m. We discuss the Marx operation at up to 21 kV charging voltage per stage, with repetition rates of up to 10 Hz in burst mode, primarily into resistive loads. A lumped circuit description of the Marx is also given, closely matching the experimental results. Design and testing of a low cost, all-metal Vircator cathode will also be discussed. (c) 2005 American Institute of Physics.

Journal

Design of Explosive-Driven Ferroelectric Pulse Generators with Outputs Exceeding 200 kV

Authors: S. Holt; J. Dickens; J. Walter; S. Calico

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4084248

Abstract: The design and testing of explosive-driven ferroelectric generators (FEGs) with output voltages exceeding 200 kV is presented. The generator design is aimed at achieving high voltages in a compact device by explosively compressing stacks of ferroelectric ceramic discs. The ferroelectric used in this application is EC -64 lead zirconate- titanate (PZT), a hard ferroelectric ceramic with a high dielectric constant and a good piezoelectric coupling coefficient in the direction of polarization. The pressure impulse is generated by high explosive detonating cord and travels longitudinally along the polarization vector in the PZT. The effect of variations in the rise-time, width, and magnitude of the pressure pulse on the peak voltage has been experimentally studied by modifying the ferroelectric stack and explosive driver geometries. Different dielectric insulations are experimentally evaluated for good compatibility with the ferroelectrics and maximum hold-off voltage.

IEEE Conferences

High Power Microwave Surface Flashover of a Gas-Dielectric Interface at 90 to 760 Torr

Authors: G. Edmiston; J. Krile; A. Neuber; J. Dickens; H. Krompholz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4084224

Abstract: The major limiting factor in the transmission of HPM has been the interface between dielectric-vacuum or even more severely between dielectric-air if HPM is to be radiated into the atmosphere. Extensive studies have identified the physical mechanisms associated with vacuum-dielectric flashover, as opposed to the mechanisms associated with air-dielectric flashover, which are not as well known. Surface flashover tests involving high field enhancement due to the presence of a triple point have shown that volume breakdown threshold (dielectric removed) is approximately 50% higher than the flashover threshold with a dielectric interface over the 90-760 torr range [1]. In order to quantify the role of field enhancement in the flashover process independent of electron injection from metallic surfaces, the effects of the triple point are minimized by carefully choosing the geometry and in some cases the triple point is "removed" from the flashover location. We will present experimental results, including the impact of gas pressure, and discuss possible causes for the difference in the rf-breakdown field with and without the interface/metallic triple point portion.

IEEE Conferences

Imaging Of Negative Polarity Dc Breakdown Streamer Expansion In Transformer Oil Due To Variations In Background Pressure

Authors: Cevallos, MD; Butcher, M; Dickens, J; Neuber, A; Krompholz, H

PDF: https://ieeexplore.ieee.org/document/1420543

Abstract: The breakdown physics of transformer oil is investigated using high speed electrical and optical diagnostics. Experiments are done in self-breakdown mode utilizing a needle/plane geometry. Shadowgraphy combined with high-speed electrical diagnostics are aimed at measuring streamer expansion as a function of external pressure. Assuming a breakdown mechanism for negative needle based on bubble formation with subsequent carrier amplification in the gas phase implies a pressure dependence, which is observed in the experiments, i.e. the expansion velocity decreases with increasing pressure.

Journal

Imaging of dielectric surface flashover in atmospheric conditions

Authors: J. Krile; A. Neuber; J. Dickens; H. Krompholz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1420431

Abstract: Using a gated intensified digital charge coupled device (ICCD) camera, the development of flashovers across a dielectric surface has been imaged in various gasses at atmospheric pressures. The arc displayed a strong tendency to develop close to the surface, as opposed to following the electric field line leading away from the surface, when oxygen is present in the environment. These findings along with spectroscopy data help to yield a better understanding of the processes involved in surface flashover.

IEEE Journals

Investigation of Charge Conduction and Self-Breakdown in Transformer Oil

Authors: M. Butcher; M. Cevallos; A. Neuber; H. Krompholz; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4084425

Abstract: With a fast coaxial setup using a needle/plane geometry and a high sensitivity electrometer, conduction mechanisms in transformer oil at varying temperature and hydrostatic pressure are quantified. There are 3 stages in the conduction process prior to breakdown for highly nonuniform field geometries. Stage I is characterized by a resistive current at low fields. Stage II consists of a rapid rise in the injection current associated with increasing field due to a "tunneling" mechanism through the metal/dielectric interface. The transition from the resistive to tunneling stage occurs when the applied field reduces the barrier at the metal/insulator interface to a point where tunneling of charge carriers through the barrier begins. This transition point is polarity dependent. In stage III, at high fields the current reaches space charge saturation at electron mobilities >100 cm2/V*s prior to breakdown. The processes of final breakdown show distinct polarity dependence. Data for the negative needle exhibits strong pressure dependence of the breakdown voltage, which is reduced by 50% if the hydrostatic pressure is lowered from atmospheric pressure to hundreds of mtorr. Such a strong pressure dependence, at reduced hydrostatic pressure, indicates breakdown is gaseous in nature. This is supported by images of bubble/low density regions forming at the current injection point. Positive needle discharges show a reduction of only about 10% in breakdown voltage for the reduced pressure case. A weak pressure dependence indicates the breakdown mechanism does not have a strong gaseous component. We will discuss possible links between conduction current and DC breakdown.

IEEE Conferences

Microbubble-Based Model Analysis Of Liquid Breakdown Initiation By A Submicrosecond Pulse

Authors: Qian, J; Joshi, RP; Kolb, J; Schoenbach, KH; Dickens, J; Neuber, A; Butcher, M; Cevallos, M; Krompholz, H; Schamiloglu, E; Gaudet, J

PDF: https://aip.scitation.org/doi/10.1063/1.1921338

Abstract: An electrical breakdown model for liquids in response to a submicrosecond (similar to 100 ns) voltage pulse is presented, and quantitative evaluations carried out. It is proposed that breakdown is initiated by field emission at the interface of pre-existing microbubbles. Impact ionization within the microbubble gas then contributes to plasma development, with cathode injection having a delayed and secondary role. Continuous field emission at the streamer tip contributes to filament growth and propagation. This model can adequately explain almost all of the experimentally observed features, including dendritic structures and fluctuations in the prebreakdown current. Two-dimensional, time-dependent simulations have been carried out based on a continuum model for water, though the results are quite general. Monte Carlo simulations provide the relevant transport parameters for our model. Our quantitative predictions match the available data quite well, including the breakdown delay times and observed optical emission. (C) 2005 American Institute of Physics.

Journal

Multi-Frequency and Multi-Mode Microwave Identification in a Vircator Research

Authors: Xupeng Chen; James C. Dickens; L. L. Hatfield; John Mankowski; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4084184

Abstract: In virtual cathode oscillator (VIRCATOR) research, multi-frequency and multi-mode microwaves are coupled out and propagate along a waveguide. Identifying the microwave propagating modes has become a priority work for further research on microwave radiation physical mechanisms. Generally, an antenna matrix at the end of an open waveguide, which can shape the radiated microwave power distribution, is used to identify the microwave propagating modes [1-2]. Actual microwave radiation mechanisms in a VIRCATOR are complicated. Multi-propagating modes and multifrequency microwaves coexist simultaneously, which challenges the antenna matrix method. In this paper, based on microwave propagating theory in a waveguide, a new method is proposed to identify multi-frequency and multi-mode microwaves, which is partially justified by the experimental data at Texas Tech University.

Conferences

Multistage Helical Flux Compression Generator Non-Explosive Test Bed

Authors: D. Belt; J. Dickens; J. Mankowski; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4084267

Abstract: Helical flux compression generators of small dimensions have been shown to produce energy output around 3 kJ into an inductive load. Adding a fuse opening switch has allowed us to produce 300 kV into a 15 Ohm load. We are investigating inductive energy storage with emphasis on an electro-explosive fuse opening switch in order to improve upon previous results. We have designed and constructed a non-explosive test bed composed of two pulse forming networks (PFN). Each PFN provides a linear approximation during two different time ranges of the exponential rise response of a typical HFCG. This approach will be more cost and time effective than to drive the fuse with an explosive generator. Our initial goal will be to simulate a 15 kA HFCG unit followed by the simulation of a 50 kA HFCG.

IEEE Conferences

Shock Induced Conductivity for High Power Switching

Authors: H. Veselka; A. Neuber; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4084322

Abstract: Investigations of shock induced conductivity of insulators and semiconductors both crystalline and noncrystalline, were performed. Although the insulator-to- metallic state transition time was measured, the focus of this investigation was on the recovery phase of the induced conductivity (i.e. metallic-to-insulator state transition). The recovery time and shock conditions were measured with high speed electrical diagnostic equipment. The goal of this research is to determine the feasibility of using shock induced conductivity as a means of producing a high power opening switch. To minimize switch losses, the insulator-to-metallic transition time and conductance is also important, but has been more widely studied. Various shock profiles and intensities and used in the study. The shock is produced primarily with conventional commercial explosives. Shock reverberation is planed in some tests to minimize sample heating and to produce tailored shock time profiles. In addition, the impacts of sample thickness and compression duration on the induced conductivity were also studied.

IEEE Conferences

Similarities of Dielectric Surface Flashover at Atmospheric Conditions for Pulsed Unipolar and RF Excitation

Authors: J. Krile; G. Edmiston; A. Neuber; J. Dickens; H. Krompholz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4084225

Abstract: Mechanisms in vacuum flashover caused by rf (f<10 GHz) or unipolar voltages are virtually identical. Similarities between rf (representing high power microwave window breakdown on the high pressure side) and unipolar flashover are expected in an atmospheric environment as well. Our experimental setups enable studying both unipolar flashover and rf window flashover at atmospheric conditions while controlling excitation, temperature, pressure, humidity, and type of gas present. The local electric field at the flashover initiating points has been numerically calculated in detail for all test geometries. For both rf and unipolar pulsed excitation, the flashover dynamics are changed by the application of UV light to the dielectric surface. A UV pre-pulse has a distinct impact on the arc's path and a tendency to increase the hold-off electric field. The effect of humidity on the hold-off electric field for both pulsed unipolar and rf excitations, along with temporally resolved emission spectroscopy of the flashover event, will be discussed.

IEEE Conferences

Simulation Studies of Liquid Water Breakdown By a Sub-Microsecond Pulse

Authors: J. Qian; R. P. Joshi; J. Kolb; K. H. Schoenbach; J. Dickens; A. Neuber; M. Cevallos; H. Krompholz; E. Schamiloglu; J. Gaudet

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4084323

Abstract: An electrical breakdown model for liquids in response to a sub-microsecond (~ 100 ns) voltage pulse is presented, and quantitative evaluations carried out. It is proposed that breakdown is initiated by field emission at the interface of pre-existing micro-bubbles. Impact ionization within the micro-bubble gas then contributes to plasma development, with cathode injection having a delayed and secondary role. Continuous field emission at the streamer tip contributes to filament growth and propagation. This model can adequately explain almost all of the experimentally observed features, including dendritic structures and fluctuations in the pre- breakdown current. Two-dimensional, time-dependent simulations have been carried out based on a continuum model for water, though the results are quite general. Monte Carlo simulations provide the relevant transport parameters for our model. Our quantitative predictions match the available data quite well, including the breakdown delay times and observed optical emission.

IEEE Conferences

The Impact of Electrode Material on the Pulsed Breakdown Strength of Water

Authors: D. Wetz; J. Mankowski; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=4084372

Abstract: In the experiments presented here, various electrode materials were tested in an effort to determine the impact each has on increasing the dielectric strength of water. Prior investigations have tested materials such as stainless steel, copper, nickel, gold, silver, and cuprous oxide [1-4]. In our experiments, thin film coatings of various metallic alloys and oxides were applied to Bruce profiled stainless steel electrodes with an effective area of 5 cm2. An ion beam sputtering process was used to apply the coatings with thicknesses of several hundred nm. The electrodes were then tested across a water gap, with pulse lengths in both the microsecond and nanosecond time regimes. Electric fields in excess of 8 MV/cm were applied. Conclusions are made as to the impact electrode material has on the pulsed breakdown strength of water.

IEEE Conferences

2004

Approximate Analytical Solutions For The Space-Charge-Limited Current In One-Dimensional And Two-Dimensional Cylindrical Diodes

Authors: Chen, XP; Dickens, J; Hatfield, LL; Choi, EH; Kristiansen, M

PDF: https://aip.scitation.org/doi/abs/10.1063/1.1743309

Abstract: In high-power microwave diode design, the space-charge-limited current is important because of its relation to the diode impedance, and the formation of the virtual cathode. Although the Langmuir-Blodgett law, as a numerical solution, is helpful, a simple functional expression would be more convenient for practical research. In this paper, a physical approximation has been introduced to analyze the nonlinear Poisson's equation in a one-dimensional (1-D) cylindrical vacuum diode. With the help of this physical approximation, a solution for the space-charge-limited current for 1-D cylindrical diodes has been investigated and developed. In addition, a comparison between our approximate result and the Langmuir-Blodgett numerical solution shows that the physical approximation method is valid in nonlinear differential equation analyses. This physical approximation can be used to analyze similar nonlinear differential equations. Also, a correction for the space-charge-limited current in a two-dimensional cylindrical diode is obtained within a limitation. (C) 2004 American Institute of Physics.

Journal

DC and pulsed dielectric surface flashover at atmospheric pressure

Authors: A. Neuber; J. Krile; J. Dickens; H. Krompholz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1433496

Abstract: In a wide variety of high voltage applications surface flashover plays a major role in the system's performance, and yet it has not been studied in great detail for atmospheric conditions with modern diagnostic tools. Environmental conditions to be considered include pressure, humidity, and gas present in the volume surrounding the dielectric. In order to gain knowledge into the underlying process involved in dielectric surface flashover, a setup has been created to produce and closely monitor the flashover event. Within the setup, parameters such as geometry, material, and temporal characteristics of the applied voltage can be altered. Current, voltage, luminosity, and optical emission spectra are measured with nanosecond to subnanosecond resolution. Spatially and temporally resolved light emission data is also gathered along the arc channel

IEEE Conferences

DC flashover of a dielectric surface in atmospheric conditions

Authors: J. T. Krile; A. A. Neuber; J. C. Dickens; H. G. Krompholz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1347231

Abstract: Surface flashover is a major consideration in a wide variety of high-voltage applications, and yet has not been studied in great detail for atmospheric conditions, with modern diagnostic tools. Environmental conditions to be considered include pressure, humidity, and gas present in the volume surrounding the dielectric. In order to gain knowledge into the underlying process involved in dielectric surface flashover, a setup has been created to produce and closely monitor the flashover event. Within the setup parameters such as geometry, material, and temporal characteristics of the applied voltage can be altered. Current, voltage, luminosity, and optical emission spectra are measured with nanosecond to subnanosecond resolution. Spatially and temporally resolved light emission data is also gathered along the arc channel. Our fast imaging data show a distinct trend for the spark in air to closely follow the surface even if an electrical field with a strong normal component is present. This tendency is lacking in the presence of gases such as nitrogen, where the spark follows more closely the electric field lines and develops away from the surface. Further, the breakdown voltage in all measured gases decreases with increasing humidity, in some cases as much as 50% with an increase from 10% relative humidity to 90% relative humidity.

IEEE Journals

Effect of temperature and pressure on DC pre-breakdown current in transformer oil

Authors: M. Butcher; A. Neuber; H. Krompholz; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1339891

Abstract: Summary form only given. Any attempt to model the complex interaction of hydrodynamic and electronic processes leading to breakdown in transformer oil suffers from the lack of microscopic transport data. Also, interface processes, such as electron emission from metal electrodes immersed in liquid, are poorly understood. As a first step toward the understanding of breakdown phenomenology, the voltage-current characteristics for pre-discharge conditions are measured. An experimental setup was constructed which allows temperature variations between 10/spl deg/C and 50/spl deg/C, at pressures between 0.5 and 3 bar. DC currents ranging from a few nA with a few kV of applied voltage, to a few /spl mu/A prior to full breakdown are measured using an electrometer. Preliminary results at NTP with a tip-plane geometry indicate Ohmic behavior at low voltages, Schottky emission at intermediate voltages, and saturation due to space charge at high voltages, and allow estimates on the physical parameters governing these effects. The indicated temperature range of the measurements is associated with a variation of the viscosity of a factor of 3, where we anticipate similar relative changes for the transport of electrons. The intermediate voltage range where a Schottky emission process is assumed will be emphasized. For instance, the electron mobility, derived from experimental data to about 0.06 cm/sup 2//Vs at NTP in the intermediate voltage range should distinctly vary with changing temperature and pressure.

IEEE Conferences

Electrical breakdown in transformer oil

Authors: M. D. Cevallos; J. C. Dickens; A. A. Neuber; H. G. Krompholz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1340174

Abstract: Summary form only given. The fundamental breakdown physics of transformer oils is investigated with high-speed electrical and optical diagnostics with temporal resolution down to 500 ps. Univolt 63 and Envirotemp FR3 (biodegradable) are used for this study. The system set up employs a cable discharge into a coaxial system with point/plane axial discharge and load line to providing a matched terminating impedance. Overall, the impedance of the system is matched at 50 ohms throughout with the exception of the very narrow gap region and includes a 50 ohm load resistor terminating the load line. Self breakdown is achieved by applying up to 50 kV to the charging line. Pulsed breakdown is achieved by charging a pulse forming line with a two way transient time of 300 ns, up to 100 kV. The pulse forming line is then fed into the discharge line via an oil spark gap. Transmission line type current sensors and a capacitive voltage divider with fast amplifiers/attenuators are used in order to attain a complete range of information from amplitudes of 0.1 mA to 1 kA with temporal resolutions of 300 ps. Optical measurements are performed on low level light emission using fast photo-multiplier tubes (risetime of 800 ps) spatially resolved, supplemented with high speed and spectroscopic investigations on a nanosecond timescale. Breakdown voltages at gap distances of 5 mm for pre, self, and pulsed breakdown voltages are given, where breakdown with negative needle tips show 20% higher breakdown voltages than the ones with positive needle. Velocities of propagating "tree"-structures for the pre and self-breakdown are a few km/s while pulsed breakdown velocities are several 10's of km/s, with higher velocities for a negative needle. The trees have to reach the opposite electrode before full breakdown occurs. Simultaneous optical measurements for a single breakdown event are presented, such as the luminosity in comparison to shadowgraphy images, which is necessary to describe the complex interaction of hydrodynamic phenomena (channel and tree formation and propagation) and charge carrier multiplication.

IEEE Conferences

Experimental optimization of a Reflex Triode Virtual Cathode Oscillator

Authors: John J. Mankowski; Xupeng Chen; James C. Dickens; Magne Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6220572

Abstract: Experimental findings on a high power Reflex Triode Virtual Cathode Oscillator (Vircator) at Texas Tech University are reported. In order to optimize performance, changes to the AK gap distance were made. The AK gap was varied from 0.5 to 1.5 cm. The type of cathode material employed was velvet. Cathode radius was 2.5 cm. The Reflex Triode Vircator is driven by a 350 kV Marx generator with a 60 ns, 20 ohm pulsed forming line. Typical peak input power is 4 GW. The output microwave power is measured in the far-field with a waveguide to coax adapter. Thus far we have observed microwave peak power output as high as 330 MW corresponding to a peak power efficiency of ~ 11 %. In an effort to provide premodulation to the vircator region, reflecting strips were added in the downstream waveguide. This technique has been employed with success by this group with a coaxial Vircator.

Conferences

Fifth Special Issue On Pulsed Power Science And Technology

Authors: Dickens, JC; Lehr, JM; Mankowski, J

PDF: https://ieeexplore.ieee.org/document/1347223

Abstract: The tradition of chronicling latest advances in pulsed power continues with this fifth edition Special Issue on Pulsed Power Science and Technology. The special issue has proven popular with scientists and engineers. Moreover, the publication of comprehensive peer-reviewed articles in a special issue of a journal devoted to the topic is increasingly recognized as personally and professionally worthwhile. This special issue is a compilation of expanded versions of some of the best papers presented at the 2003 International Pulsed Power Conference (PPC), held in Dallas, TX, June 15–18, 2003. The Proceedings of the Pulsed Power Conference is the premiere forum for exchanging results and ideas in the area of pulsed power and related technologies. In the last decade, the Pulsed Power conferences have been very successful, as is evident from the number of participants and quality papers, with over 25 countries represented. The 2003 PPC is no exception, with 584 registrants from 22 countries and 477 papers. Even with the extraordinary and unprecedented problems in obtaining visas for many foreign participants, the conference still recorded 180 registrants from outside the United States. Pulsed power technology has traditionally been dominated by military applications with some civilian efforts primarily in the area of controlled nuclear fusion. More recently, however, the number of civilian applications has grown considerably. Of particular interest are the areas of biological and medical applications, compact pulsed power, and repetitive pulsed power systems. It is interesting to note that the contributed papers to this special issue are roughly evenly divided between components, fundamental phenomena, systems and applications. All but a few of the papers in this issue are based on the presentations given at the International Pulsed Power Conference. The reader of this Fifth Special Issue on Pulsed Power Science and Technology will also see this truly international participation reflected in the contributed papers. Similarly, the diverse nature of the pulsed power community is reflected in the originating institutions of universities, industry, and government laboratories. Making a clear classification between the topics covered in this issue has been a challenging task since the topics range from flashover phenomena to pulsed power driven sterilizing technology, and from directed weapon technology to explosively driven pulsed power to miniature hole drilling industrial applications. This Fifth Special Issue on Pulsed Power Science and Technology for the IEEE Transactions on Plasma Science has been an extraordinary and enjoyable experience for each of the three Guest Editors. Solicitation of papers is largely conducted through advertisement at the Pulsed Power Conference and, now, tradition. The peer review process, however, was greatly facilitated by the introduction of IEEE's ManuscriptCentral. ManuscriptCentral is a semi-automated electronic database for manuscript control and processing, that was adopted last year by the Transactions on Plasma Science, and championed by Editor-in-Chief Steve Gitomer. It truly has been a revolutionary advance in the synthesis of special issues, a mainstay of the Transactions on Plasma Science, by effectively eliminating the physical distance between the Editor-in-Chief, Guest Editors, referees, and authors. As Guest Editors, we would like to extend our gratitude to the Editor-in-Chief, Steve Gitomer, for his many kindnesses, his patience, and his vigilance. We would like to express our gratitude to both the authors and the referees for their contributions to our profession. In particular, we thank the referees for their understanding, patience, and noble efforts of reviewing the manuscripts. Jane Lehr would like to thank Dr. John Maenchen and Mrs. Beverly Rudys for their encouragement and support for this effort. Jim Dickens and John Mankowski would like to thank their colleagues at Texas Tech University for their many contributions to the success of this special issue. We would also like to extend our thanks and appreciation to our colleagues of the IEEE Nuclear and Plasma Sciences Society, Pulsed Power Science and Technology Standing Committee for their unwavering support and encouragement, for with their vision, and leadership of the pulsed power community, this Biannual Special Issue on Pulsed Power Science and Technology is a tradition.

Journal

Light-matter interaction in transformer oil

Authors: T. Namihira; D. Wang; A. Neuber; M. Butcher; J. Dickens; H. Krompholz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=1340266

Abstract: Summary form only given. Considering highly stressed dielectric liquids, the role of mechanisms such as photoionization in the liquid volume or photoeffect at the cathode for the development of dielectric breakdown is investigated. We used a pulsed 300 W Xenon light source (25 mm output window, 5 degree divergence) with a broad spectral range of 200 to 1100 nm to study the impact of the light beam focused either solely on the high field region between the breakdown electrodes or including the electrodes. Typical field strengths in the electrode gap (/spl sim/4 mm gap, 3 mm tip radius,) were 15 to 25 kV/cm resulting in a DC current amplitude (without light) of up to 2 nA (apparatus resolution /spl sim/10 pA). Standard transformer oil, Univolt 61, and a biodegradable oil, Environtemp FR3 (natural ester fluid), were examined in the present work. Both oils exhibit strong optical absorption in the UV. However, Univolt 61 has its cut off wavelength at 450 nm, while bio oil easily transmits down to 350 nm. Below the cutoff wavelength, virtually all radiation is absorbed within a few mm. When pulsing the Xenon lamp at /spl sim/500 microsec no increase in DC current amplitude (increase <10 pA) could be detected for either oil. Increasing the pulse length to several seconds lead to a distinct increase in current amplitude (up to 300 pA), however, only for Univolt 61. Such an increase in current amplitude can also be achieved by raising the temperature of the dielectric liquid by external heating (/spl sim/100 pA/K). The temperature levels leading to similar current amplitudes due to heating by the Xenon lamp or external heating are comparable. Since bio oil absorbs only below 350 nm, the temperature rise due to the light irradiation was comparably smaller than in Univolt 61. Thus, any heating and increase in current were less pronounced in bio oil. For both oils, the observed behavior can be entirely explained by thermal effects. Both, photoionization and photoeffect have seemingly a minor impact on breakdown development. The detailed discussions are given in the present work.

Conferences

Magnetic flux compression Generators

Authors: A. A. Neuber; J. C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1306688

Abstract: Magnetic flux compression generators offer the largest pulsed power output per unit size or weight when compared with other more conventional systems. They have found widespread use as pulsed power sources for hydrodynamics programs and high magnetic field research at national laboratories or in commercial applications, including exploration for oil and minerals and mine detection. Also, due to their nature as a true one-time-use device with superior energy density, a large portion of applications is defense related. A variety of basic magnetic flux compression generator designs have been developed and tested during the past four decades. All of them rely on the explosive-driven deformation of a system of conductors having an initial, preferably large, inductance. The most successful basic design is the helical flux compression generator, which is capable of producing a high-energy output into large impedance loads, just as it is needed for a practical pulsed power source. This paper will review the advances and state of the art of primarily helical magnetic flux compression generators mainly developed as pulsed power sources and will offer new insights gained as a result of a recently completed five-year AFOSR/DoD Multidisciplinary University Research Initiative program that studied the basic physics and engineering aspects of helical flux compression generators.

IEEE Journals

Microwave frequency determination mechanisms in a coaxial vircator

Authors: Xupeng Chen; J. Dickens; J. Mankowski; L.L. Hatfield; Eun Ha Choi; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=1347227

Abstract: Traditionally, the radiated microwave frequency in a coaxial vircator is considered to be determined primarily by the virtual cathode oscillation frequency and the electron reflection frequency. In this paper, some experiments showing different results are reported. In particular, the E-beam is observed to play an important role in the cavity formation. Some possible explanations, including a virtual cavity concept, are proposed. The cavity resonance effect on a coaxial virtual cathode oscillator with different geometries has been investigated in detail. Investigation of the E-beam performance will improve understanding of the interaction between the E-beam and microwaves, which is a key for determining the microwave frequency. These results are helpful in optimizing the design of a cylindrical diode to avoid microwave frequency shifting and mode competition.

Journals

Quantification of ohmic and intrinsic flux losses in helical flux compression Generators

Authors: J.C. Hernandez; A.A. Neuber; J.C. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=1347243

Abstract: Helical magnetic flux compression generators (MFCGs) are the most promising energy sources with respect to their current amplification and compactness. They are able of producing high current pulses required in many pulsed power applications with at least one order of magnitude higher energy density than capacitive storage with similar discharge characteristics. However, the main concern with MFCGs is their intrinsic flux loss that limits severely their performance and which is not yet well understood. In general, all flux losses have a differing degree of impact, depending on the generator's volume, current and energy amplification, size of the driven load, and angular frequency of armature-helix contact point. Although several computer models have been developed in the open literature, none of them truly quantify, starting from basic physics principles, the ohmic and intrinsic flux losses in helical MFCGs. This paper describes a novel method that provides a separate calculation of intrinsic flux losses (flux that is left behind in the conductors and lost for compression) and ohmic losses, being especially easy to implement and fast to calculate. We also provide a second method that uses a simple flux quantification, making a mathematical connection between the intrinsic flux losses, quantified by the first method, and the intrinsic flux losses observed in the generators. This second method can also be used to a priori estimate the MFCG performance. Further, we will show experimental and calculated data and discuss the physical efficiency limits and scaling of generator performance at small sizes.

Journals

Research issues in developing compact pulsed power for high peak power applications on mobile platforms

Authors: J.A. Gaudet; R.J. Barker; C.J. Buchenauer; C. Christodoulou; J. Dickens; M.A. Gundersen; R.P. Joshi; H.G. Krompholz; J.F. Kolb; A. Kuthi; M. Laroussi; A. Neuber; W. Nunnally; E. Schamiloglu; K.H. Schoenbach; J.S. Tyo; R.J. Vidmar

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=1306684

Abstract: Pulsed power is a technology that is suited to drive electrical loads requiring very large power pulses in short bursts (high-peak power). Certain applications require technology that can be deployed in small spaces under stressful environments, e.g., on a ship, vehicle, or aircraft. In 2001, the U.S. Department of Defense (DoD) launched a long-range (five-year) Multidisciplinary University Research Initiative (MURI) to study fundamental issues for compact pulsed power. This research program is endeavoring to: 1) introduce new materials for use in pulsed power systems; 2) examine alternative topologies for compact pulse generation; 3) study pulsed power switches, including pseudospark switches; and 4) investigate the basic physics related to the generation of pulsed power, such as the behavior of liquid dielectrics under intense electric field conditions. Furthermore, the integration of all of these building blocks is impacted by system architecture (how things are put together). This paper reviews the advances put forth to date by the researchers in this program and will assess the potential impact for future development of compact pulsed power systems.

Journals

Voltage-current characteristic of transformer oil under high electrical stress

Authors: M. Butcher; A. Neuber; H. Krompholz; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1339892

Abstract: Summary form only given. The scattering cross-sections, transport coefficients, and details of the breakdown mechanism needed for describing current conduction in transformer oil at high applied voltages are virtually unknown. This makes it extremely difficult, if not impossible, to properly model electrical breakdown in oil. To address this issue, we have measured the V-I characteristic of transformer oil in the point-plane geometry for /spl sim/3 mm gap widths. Three regimes can be distinguished. (1) For low voltages, V <3 kV, the relationship between voltage and current is linear, exhibiting just resistive behavior within the measurement accuracy. (2) At intermediate voltages, the dependence is linear on a Fowler-Nordheim plot. (3) Between the breakdown voltage V/sub B/ /spl sim/ 30 kV and 10 kV, the current is proportional to V/sup 2/, indicating space charge limited current. Assuming a Schottky-type emission mechanism for electrons injected into the liquid, we derive an electron mobility of /spl sim/6.0/spl times/10/sup -6/ m/sup 2//Vs, which is close to values reported in the literature before. Assuming Fowler-Nordheim emission leads to 3.8/spl times/10/sup -6/ m/sup 2//Vs. The ion mobility is believed to be more than one order of magnitude lower. At this point, it is difficult to gain any more detailed information on charge transport and possible multiplication based on simple analytical methods. Hence, we applied our numerical modeling techniques already proven in analyzing high-field phenomena in polar liquids (e.g., water), to evaluate current conduction and the breakdown process in non-polar oil. By comparing our calculations with the experimental data, we hope to characterize important transport parameters, such as the electron ionization coefficient as a function of the electric field. We also present our attempts to extract details of the field-dependent non-linear processes and electrode effects close to the breakdown regime.

IEEE Conferences

2003

Cavity resonance effect on a coaxial vircator

Authors: Xupeng Chen; J. Dickens; Eun Ha Choi; J. Mankowski; L.L. Hatfield; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=1278019

Abstract: Traditionally, the radiated microwave frequency in a coaxial vircator is considered to be determined primarily by the virtual cathode oscillation frequency and the electron reflection frequency. However, some experiments at TTU show that the interaction between the virtual cathode oscillation and the cavity is a key in determining the microwave frequency and propagating mode. Particularly, we observe that the E-beam plays an important role in the cavity formation. Some possible explanations, including a virtual cavity concept, are proposed. The cavity resonance effect on a coaxial virtual cathode oscillator has been investigated in detail. The understanding of the E-beam characteristics is critical in optimizing the design of the cylindrical diode to avoid the microwave frequency shifting and mode competition.

Conferences

Compact, Portable Pulsed Power: Physics And Applications

Authors: Gundersen, M; Dickens, J; Nunnally, W

PDF: https://ieeexplore.ieee.org/document/1277651

Abstract: We describe an academic research program designed to investigate fundamental issues that will impact future pulsed power technology. The project is intended to enhance the scientific footing for pulsed power, and to address issues in the development of compact, repetitive pulsed power. These include physics issues implicit in switch development, including both solid state and gas-phase, pulse generation at various levels from extremely small for fast high field generation to >100kV, and applications including ignition of jet fuels and biological response to electric fields.

Conference Paper/Presentation

Completely Explosive Pulsed Power Minisystem

Authors: Talantsev, EF; Shkuratov, SI; Dickens, JC; Kristiansen, M

PDF: https://aip.scitation.org/doi/abs/10.1063/1.1527719?journalCode=rsi

Abstract: It is demonstrated that it is feasible to produce pulsed power using an autonomous completely explosive system that harnesses two physical phenomena successively: the transverse shock wave demagnetization of Nd2Fe14B high-energy hard ferromagnets and magnetic cumulation. (C) 2003 American Institute of Physics.

Journal

Conductivity measurements of explosively shocked aluminum and OFHC copper used for armature material in a magnetic flux compression generator

Authors: D. Hemmert; J. Mankowski; J. Rasty; A. Neuber; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1277997

Abstract: Modeling and characterization of a magnetic flux compression generator (MFCG) requires detailed knowledge of the changes in conductivity of the MFCG materials during the shock-loading phase. In the studies reported here, a thin metallic strip is shocked with an explosively generated shock wave produced from a charge of composition C-4. The shock wave is intended to simulate the shock wave and pressures produced in MFCG research currently being conducted at Texas Tech University. These pressures are estimated to be between 1 and 3 GPa. The experimental setup is arranged so that the shapes of the metallic strip and shock front are the same, as confirmed using optical fibers. This was to ensure that the test sample was shocked uniformly. The metallic test strip is pulsed with a 70 A current pulse during application of the shock wave. The current and voltage across the test sample are measured directly to determine the change in conductivity. Pressure measurements are conducted in separate tests under similar conditions using strain gauges. The results are then compared to results determined previously using a split Hopkinson pressure bar apparatus (SHPB).

IEEE Conferences

Currents Produced By Explosive Driven Transverse Shock Wave Ferromagnetic Source Of Primary Power In A Coaxial Single-Turn Seeding Coil Of A Magnetocumulative Generator

Authors: Shkuratov, SI; Talantsev, EF; Dickens, JC; Kristiansen, M

PDF: https://aip.scitation.org/doi/10.1063/1.1558968

Abstract: Experimental and digital simulation studies of the generation of seed currents by an ultracompact (8.66-8.75 cm(3) in volume) ferromagnetic explosive-driven generator of primary power (FMG) loaded on the coaxial single-turn seeding coil of a magnetocumulative generator (MCG) have been performed. The operation of the FMG is based on transverse shock wave demagnetization of Nd2Fe14B high-energy hard ferromagnets. The FMG is capable of producing in the coaxial seeding coil of MCG a seed current with peak amplitude I(t)(max)=3.0 kA and full width at half maximum of 60 mus. The methodology was developed for digital simulation of the seeding processes in the combined FMG/MCG system. (C) 2003 American Institute of Physics.

Journal

Design criteria for prevention of armature "turn-skipping" in helical magnetic flux compression generators

Authors: J. Rasty; X. Le; J. Dickens; A. Neuber; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1277998

Abstract: Helical magnetic flux compression generators (MFCGs) are capable of producing ultra-high power electric pulses by trapping and compressing a seed magnetic field into a load coil via an explosive-driven armature. The efficiency of helical MFCGs is generally very low, about 10%, due to large magnetic flux losses. One of the main sources of magnetic flux loss is the "turn-skipping" phenomenon, in which the expanding armature fails to establish contact with every turn of the helical coil, resulting in magnetic flux loss in the skipped turns of the coil. The "turn-skipping" phenomenon is related to non-uniform or asymmetric expansion of the armature, as well as detonation end effects. Equations describing the "turn skipping" phenomenon are developed in terms of the eccentricity of the armature with respect to the helical coil, the armature's wall thickness variations and the length of the detonation end effect. Design criteria for prevention of "turn-skipping" are presented in order to achieve optimum MFCG performance.

IEEE Conferences

Efficiency results from a coaxial vircator using a simple feedback technique

Authors: J. Mankowski; X. Cheng; J. Dickens; M. Kritiansen; E. Choi

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1277749

Abstract: Experimental findings on the coaxial virtual cathode oscillator (vircator) at Texas Tech University are reported. A major modification to the system extended the pulse forming line several meters. The pulsed power system now delivers up to 750 kV and 60 kA for at least 70 nsec. Additional modifications include diagnostics to measure the diode voltage, current, and radiated field pattern of the output microwaves. In this initial phase of experiments copper reflectors were installed within the diode to provide a simple means of microwave feedback to assist in the e-beam modulation. Thus far we have observed microwave peak power output with feedback reflectors as high as 3.5 GW corresponding to an efficiency of /spl sim/9.5%. Measured radiated field patterns show evidence of multimode operation.

IEEE Conferences

Experimental results of a 2 GW vircator

Authors: J. J. Mankowski; E. H. Choi; J. C. Dickens; Xupeng Chen; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1228654

Abstract: Summary form only given, as follows. Summary form only given. Experimental findings on the coaxial virtual cathode oscillator (vircator) at Texas Tech University are reported. Recent modifications to the system include extending the pulse forming line that now provides an applied diode voltage of 600 kV for 70 nanoseconds at 60 kA. Other modifications include diode voltage, current, and radiated field diagnostics. In this initial phase of experiments, copper reflectors were installed within the diode to provide a simple means of microwave feedback to assist in the e-beam modulation. Thus far we have observed microwave peak power output with feedback reflectors as high as 2 GW corresponding to an efficiency of -6%. The mode observed at these high efficiencies is almost entirely TE/sub 11/. At lower efficiencies, both TM/sub 01/, and TE/sub 11/ modes are observed. These results suggest mode competition at lower efficiencies.

IEEE Conferences

Ferromagnetic and ferroelectric materials as seed sources for magnetic flux compressors

Authors: N. Schoeneberg; J. Walter; A. Neuber; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=1277996

Abstract: An alternative to the use of capacitors as the seed source for flux compression generators (FCG) are permanent magnet based systems. Permanent magnets provide a larger energy-to-volume ratio given that the use of capacitors requires a power source as well as charging and firing circuitry. A recent design developed at Texas Tech University's Center for Pulsed Power and Power Electronics [S.I. Shkuratov, et al., 2002], focused on the demagnetization of a Neodymium-Iron-Boron magnet (Nd/sub 2/Fe/sub 14/B, B/sub r/= 1.23 T) by a shockwave generated from high explosives. The maximum specific energy achieved with this design was only 2.3 J/kg, which may not be sufficient for effectively seeding an FCG (fast capacitors have at least 20 J/kg). The same magnets were used with an alternative design, referred to as a strip FCG, which utilizes opposing magnets to generate initial magnetic field intensity within an air gap. The air gap exists between a central tube, filled with high explosives, and metal strips placed between the magnets a few millimeters off-axis. The detonation of the explosive causes the expansion of the central tube, subsequently compressing the flux into the strips and then into the load. The original strip FCG design [B.A. Bojko, et al., 1994] used oxide-barium magnets (B/sub r/= 0.2T), which produced an estimated specific energy of 5.27 J/kg into a low inductance load. These magnets were replaced with the Nd/sub 2/Fe/sub 14/B (B/sub r/= 1.23 T) magnets in order to achieve better performance, which will be analyzed with respect to the specific energy. In addition, a design utilizing a shocked ferroelectric material, PZT, as a seed current source is discussed. An explosively generated shock wave is passed through a ferroelectric material, generating a current that establishes the initial seed flux for an FCG. Preliminary tests of the ferroelectric sources indicate a possible theoretical specific energy of more than 11 J/kg or 25 J/dm/sup 3/. A comparison of the designs will be discussed with regard to the specific energy produced and the effectiveness of each to seed FCG's.

Conferences

Investigation of pulse power thyristor thermal variations

Authors: M.G. Hoffman; J.C. Dickens; M.G. Giesselmann

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=1277679

Abstract: This paper presents a study of temperature variations in a Pulse Power Thyristor (PPT) during and after discharge. The PPT studied was the SPT411BHT. The SPT411BHT is a 5000 V, 4600 A, 125 mm thyristor made by Silicon Power Corporation. In order to determine the temperature of the PPT silicon, a 125 mm diode with identical thermal properties is placed in series with the PPT. There is a strict relationship between the forward voltage and the silicon temperature of the diode. Measurement of the forward voltage of the diode before and after discharge will accurately predict the temperature increase of the silicon. Peak discharge currents will be varied from 30 kA to 90 kA. The forward voltage measurement circuit must be able to resolve millivolts in the presence of common mode voltages in excess of 2 kV. Also, the circuit must isolate the measurement equipment from the circuit. This paper will discuss the temperature measurement concept as well as the design details of the circuit used to measure the diode forward voltage.

Conferences

Investigation of ultra-high switching frequency to reduce size in rapid capacitor charging

Authors: B. W. Morris; J. C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1278086

Abstract: A compact high switching frequency rapid capacitor charging supply was designed and implemented. The challenges of topology design, component selection and implementation are discussed. The end goal is a supply capable of achieving 40 kW at 40 kV on the output and 100-300 V input. The gate driver design is discussed with particular emphasis on gate voltage rise-time and propagation delay. Switching frequencies from 100 kHz to 1 MHz are explored. Transformer and output voltage multiplier designs are also described with expected performance parameters based upon computer simulations.

IEEE Conferences

Longitudinal-Shock-Wave Compression Of Nd2Fe14B High-Energy Hard Ferromagnet: The Pressure-Induced Magnetic Phase Transition

Authors: Shkuratov, SI; Talantsev, EF; Dickens, JC; Kristiansen, M; Baird, J

PDF: https://aip.scitation.org/doi/10.1063/1.1554486

Abstract: A study of a magnetic phase state of Nd2Fe14B high-energy hard ferromagnets subjected to longitudinal-shock-wave compression (where the shock wave propagates along magnetization vector M) has been performed. The results of the investigation show that longitudinal-shock-wave compression of Nd2Fe14B at 28-38 GPa causes a magnetic phase transition terminated by practically complete demagnetization of Nd2Fe14B. Due to this phase transition all electromagnetic energy stored in Nd2Fe14B is released and can be transformed into pulsed power. Explosive-driven autonomous sources of primary power utilizing this effect are capable of producing high-current pulses [current amplitude of 1.0 kA, full width at half maximum (FWHM) of 165 mus] and high-voltage pulses (peak voltage of 13.4 kV, FWHM of 8.2 mus). (C) 2003 American Institute of Physics.

Journal

Nanosecond laser-triggered microwave switch

Authors: M. M. McQuage; A. A. Neuber; J. C. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1277717

Abstract: The design and experimental testing of a laser-triggered microwave switch with a nanosecond activation time is described. The objectives of the project include, confirming that a nanosecond to subnanosecond risetime is achievable in the X-band waveguide at 9 GHz with the laser-triggered switch and to determine the minimum laser energy necessary to obtain the fastest possible risetime. A 1 kW pulsed X-band source with a 500 ns output pulse provides the microwave power for the system. A variable power Nd:YAG laser with a maximum 450 mJ at 532 nm, 10 ns FWHM output pulse is used in conjunction with an applied high voltage pulse to trigger the microwave switch. The microwave signal is switched with the rapid formation of plasma caused by the breakdown of a gas contained by a quartz tube inserted through a section of waveguide. The centerpiece of the waveguide system is a magic tee, which controls the direction of power flow through the system. Compared to tests in air and N/sub 2/, the best results have been obtained in argon. Risetimes below 2 ns have been obtained using argon at a reduced pressure of 150 Torr and a high voltage pulse of 28 kV from a spark gap. The impact of gas pressure, applied voltage pulse and applied laser pulse on the risetime of the microwave switch are discussed.

IEEE Conferences

Optical diagnostics of liquid nitrogen volume pre-breakdown events

Authors: M. Butcher; A. Neuber; H. Krompholz; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=1277987

Abstract: An increased need for compact pulsed power systems requiring new switching technologies combined with the benefits of cryogenic properties, such as higher energy density and miniaturization, has lead to increased interest in liquid nitrogen as a switching medium. High hold off voltage, low dielectric constant, and low environmental impact are further advantages of liquid nitrogen. Characterization of breakdown is investigated using high-speed (temporal resolution < 1 ns) optical and electrical diagnostics in a coaxial system with 52 /spl Omega/ impedance. Experiments are done in self-breakdown mode in super-cooled liquid nitrogen with a temperature near 70 K. Discharge current and voltage are determined using transmission line type current sensors and capacitive voltage dividers. Discharge luminosity is measured with photomultiplier tubes (risetime/spl ap/800 ps) that are focused on the negative electrode tips and the center of the channel. Optical investigations of breakdown and pre-breakdown events on a nanosecond time scale will provide a better understanding of the fundamental physics of breakdown formation. Detailed optical and spectroscopic diagnostics combined with high-speed electrical diagnostics are aimed at clarifying the overall breakdown mechanisms, including electronic initiation and bubble formation. The breakdown initiation/development will be discussed.

Conferences

Phenomenology of conduction and breakdown in transformer oil

Authors: M. Butcher; M. Cevallos; M. Haustein; A. Neuber; J. Dickens; H. Krompholz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1254853

Abstract: In a coaxial test apparatus enabling the measurement of voltage and current at the test gap, dc conduction and breakdown in transformer oil caused by the application of dc voltages are investigated. Current measurements cover the range from 10/sup -1/ A to 1 kA, with temporal resolutions of milliseconds at the lowest current amplitudes to sub-nanoseconds for currents larger than 10/sup -4/ A. The dc current/voltage characteristic for sub-breakdown voltage amplitudes point to the injection of charge carriers, allow us to characterize the transport mechanisms, and the influence of space charges. For voltages approaching breakdown thresholds, quasi dc-currents rising from nanoamperes to microamperes are superimposed by current pulses with amplitudes of milliamperes and above, and durations of nanoseconds. The onset of these current pulses occurs up to 10 /spl mu/s before breakdown. One of these current pulses reaches a critical amplitude causing voltage breakdown and current rise to the impedance-limited value within 2 ns. Additional optical diagnostics using photomultipliers and high-speed photography with gated microchannel plates yield information on hydrodynamic processes and charge carrier amplification mechanisms associated with the current pulses and final breakdown, such as bubble formation, as well as on the development of the spark plasma finally bridging the gap.

IEEE Conferences

Physical efficiency limits of inch-sized helical MFCG's

Authors: A. A. Neuber; J. -. Hernandez; T. A. Holt; J. C. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1277740

Abstract: Helical magnetic flux compression generators (MFCG) are attractive energy sources with respect to their specific energy output. A variety of one-time use applications would benefit from small inch-sized helical generators with high specific energy output. However, it is widely accepted that the generator performance deteriorates with decreasing size. Previous experimental data have shown that the increase of the ohmic resistance of the MFCG with a reduction in size is the primary cause for the observed behavior when the initial generator inductance is held constant. We will analyze the situation in more depth and quantify how much the efficiency is determined by ohmic losses and intrinsic flux losses (flux that is left behind in the conductors and lost for compression) for different generator sizes and geometries. Our simple constant diameter MFCGs exhibit more intrinsic than ohmic losses (69% compared to 16%), while our MFCGs with tapered armatures display less intrinsic and more ohmic flux losses (13% compared to 66%), however, at increased overall efficiency. We will show experimental and calculated data and discuss the physical efficiency limits and scaling of generator performance at small sizes.

IEEE Conferences

Physics Of Dielectric Surface Flashover At Atmospheric Pressure

Authors: Krile, J; Neuber, A; Dickens, J; Krompholz, H

PDF: https://ttu-ir.tdl.org/handle/2346/12789

Abstract: The limits of the applicability of dc, ac, or pulsed high voltage are determined by breakdown along insulators or insulating support structures. It is of major technical importance to predict breakdown voltages for given structures, with parameters such as geometry, material, and temporal characteristics of the applied voltage. The impact of atmospheric conditions such as humidity, pressure, temperature, and types of gas present is also important. A setup has been devised to simulate and closely monitor flashover across various gap distances and insulator geometries at atmospheric conditions at different humidities. Current, voltage, luminosity, and optical emission spectra were measured with nanosecond to sub-nanosecond resolution. Spatially and temporally resolved light emission data yielded quantitative information about the charge carrier amplification, the location of this amplification, and its role in the formation of streamers.

Conference Paper/Presentation

Prebreakdown current behavior in DC volume breakdown in transformer oil

Authors: M. Butcher; A. Neuber; H. Krompholz; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1277712

Abstract: The phenomenology of prebreakdown events in transformer oil is investigated using high-speed electrical and optical diagnostics. Data collection using a coaxial test setup terminating into a 50/spl Omega/ load line to simulate a matched impedance system allows very fast risetimes. Transmission line type current sensors and capacitive voltage dividers with temporal resolution of 300 ps provide information about the discharge voltage and current. Steady, DC currents ranging from a few nA with less than 10 kV of applied voltage, to a few /spl mu/A prior to full breakdown are measured using an electrometer. Prebreakdown events are measured with positive and negative charging voltages with respect to ground. Light emission from the discharge is measured using a series of fast photomultiplier tubes, (risetimes 800 ps), that observe positive and negative electrode tips and center of the channel. Preliminary results on self-breakdown (breakdown voltage +44 kV) with a 2.35 mm gap show a DC (seed) current of several hundred nA with prebreakdown spikes of a few mA immediately before final breakdown. Periodicity of the current spikes combined with a general increase in magnitude prior to full breakdown has been observed. Data collection using a negative charging line, with respect to ground with enhanced field at the cathode, indicates current spikes that are typically 25 to 50% faster than spikes using a positive charging line with enhanced field at the anode. Detailed optical diagnostics along with high-speed electrical diagnostics of the pre-breakdown phase will address the physical mechanisms initiating volume breakdown.

IEEE Conferences

Pulsed and self electrical breakdown in biodegradable oil

Authors: M. D. Cevallos; J. C. Dickens; A. A. Neuber; M. A. Haustein; H. G. Krompholz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1228897

Abstract: Summary form only given, as follows. The fundamental breakdown physics of biodegradable oil is investigated with a set up that employs a cable discharge into a coaxial system with axial discharge and load line to simulate a matched terminating impedance. No discontinuities are created in the system lines when entering the discharge chamber with the implementation of a unique feed-through design. The entire impedance of the system is matched at 50 ohms. A novel design for impedance matching transitions from the discharge cable to the coaxial system to the load line allow for a sub-nanosecond response. Final results are measured on pulsed and self breakdown voltages of up to 200 kV. Self breakdown is achieved by charging the discharge cable and load line to +/- 100 kV respectively. Pulsed breakdown is achieved by charging the discharge cable and load line to +100 kV. Shorting the discharge cable generates a reflected negatively polarized pulse causing breakdown. High speed electrical and optical diagnostics have temporal resolution down to several 100 ps A complete range of information from amplitudes of 0.1 mA to 1 kA with temporal resolutions of 300 ps is achieved by using transmission line type current sensors with fast amplifiers. Capacitive voltage dividers with fast attenuators are also used. Optical measurements are performed on low level light emission using spatially resolved, fast photo-multiplier tubes (risetime of 800 ps), supplemented with high speed photography and spectroscopic investigations on a nanosecond timescale Detailed optical and spectroscopic diagnostic along with high speed electrical diagnostics will address the mechanism initiating/assisting biodegradable oil volume breakdown.

IEEE Conferences

Reflex-Triode Geometry Of The Virtual-Cathode Oscillator

Authors: Lara, MB; Mankowski, J; Dickens, J; Kristiansen, M

PDF: https://ieeexplore.ieee.org/document/1278018

Abstract: An eight-stage four-hundred kilovolt Marx bank, in connection with a 60 nanosecond pulse-forming line, is constructed and utilized as a pulsed source to power a planar version of the Virtual Cathode Oscillator (Vircator). Eight 1upsilonF capacitors, charged to 50kV each, are switched in series by dry-air pressurized spark gaps. The energy from the bank charges a 23 ohm oil transmission line, breaking a peaking gap when the maximum voltage is reached, delivering a 60 ns-300kV pulse to the diode. The design of the Planar or Reflex-Triode geometry Vircator is based upon claims of high efficiency by Didenko et al. A previously constructed TTU Vircator includes a unique E-beam source, the brush cathode; in which a circular array of pins is used as an explosive field emission source to produce relatively high beam currents. The anode consists of a round wire mesh through which the E-beam passes, generating a dense cloud of negative charge known as a Virtual Cathode. This initial phase of testing is composed of basic operation of the entire system and baseline output power and efficiency measurements.

Conference Paper/Presentation

Self electrical breakdown in biodegradable oil

Authors: M.D. Cevallos; J.C. Dickens; A.A. Neuber; M.A. Haustein; H.G. Krompholz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=1277989

Abstract: The fundamental breakdown physics of biodegradable oil is investigated with high-speed electrical and optical diagnostics with temporal resolution down to several 100 ps. The set up employs a cable discharge into a coaxial system with axial discharge and load line to simulate matched terminating impedance. A unique feed-through design creates no discontinuities in the system lines through the discharge chamber. The impedance of the system is matched at 50 ohms including a novel design for impedance matching transitions from discharge cable to coaxial system to load line allowing for a sub-nanosecond response. This paper presents results on self-breakdown with voltages of up to 60 kV. Self-breakdown is achieved by charging the discharge cable and load line to +/-30 kV respectively. Transmission line type current sensors and a capacitive voltage divider with fast amplifiers/attenuators are used in order to obtain a complete range of information from amplitudes of 0.1 mA to 1 kA with temporal resolutions of 300 ps. Optical measurements include high speed photography and shadowgraphy. Detailed optical diagnostics along with high-speed electrical diagnostics will address the mechanism initiating/assisting biodegradable oil volume breakdown.

Conferences

Short pulse electric field sterilization of liquid media

Authors: D. Wetz; K. Truman; J. Dickens; J. Mankowski; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1278009

Abstract: In recent years, researchers have investigated methods of liquid sterilization by applying pulsed high electric fields with some degree of success. The mechanism by which microorganisms are damaged has been shown to be a function of the local electric field and exposure time while independent from thermal and electrolytic effects from the applied pulse. Most published experiments have employed electrical pulses of 10's of kV and microsecond long pulse lengths. We are employing electrical pulses in the 100's of kV range with 100 nanosecond long pulse lengths. This type pulse should be more effective at killing microorganisms and minimize energy losses due to thermal processes in the liquid media.

IEEE Conferences

Single shot overstressing of high voltage capacitors for compact Arkadiev-Marx generator

Authors: S. I. Shkuratov; E. F. Talantsev; J. C. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1277810

Abstract: Five different types of high voltage capacitors have been tested to determine their maximum high voltage overstress coefficient. Chicago condenser, Reynolds industries, Hivolt, and TDL capacitors of capacitance 100 nF and different nominal voltages were tested in the single shot mode. Experiments have shown that the energy stored under overstress conditions in all types of the capacitors tested is 10 to 20 times more than the nominal energy.

IEEE Conferences

Small sized MFCG for driving a high impedance load

Authors: J. -. Hernandez; A. A. Neuber; J. C. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1277995

Abstract: End-initiated small volume magnetic flux compression generators (MFCG) have at least one order of magnitude higher energy density (by weight or volume) than capacitive energy storage with similar discharge time characteristics. Since the prime energy is built into the MFCG in form of HE, the capacitor looses even more ground if the necessary prime energy source and the charging supply are included in the weight/volume balance. However, simple MFCGs with a single helix produce high output energy only into low inductance loads, thus producing several 100 kA of current at a voltage level of only a few 10 kV. Many pulsed power devices require less current but a considerably higher voltage level. Two approaches for achieving a higher output voltage level, both utilizing two staged MFCGs, have been reported in the open literature. The first employs a more traditional transformer coupling; the second relies on a dynamic transformer or flux-trapping scheme. Although the traditional transformer coupling has theoretically the better efficiency, we chose the latter approach for our generator design, mostly since it requires a smaller number of components. Our generator has a total length of 250 mm, a helix inner diameter of 51 mm, and is wound with Teflon insulated stranded wire of different sizes in the range from AWG 12 to AWG 22. We have presently achieved an energy gain of /spl sim/ 8 and will discuss the generator performance based on experimental current/voltage waveforms.

IEEE Conferences

Space-charge limited current for 1-D cylindrical diodes

Authors: X. Chen; K. Dickens; E.H. Choi; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=1277752

Abstract: By introducing a physics approximation method into analyzing the nonlinear Poisson's equation, an analytical expression for the space-charge-limited current density for a one-dimensional (1-D) cylindrical diode has been investigated and developed. This expression is different from Child-Langmuir law for the planar diode and is simpler than Langmuir-Blodgett law for the cylindrical diode. This expression builds an explicit connection between the current density and the physical parameters, which is helpful in optimizing the design of the cylindrical vacuum diode. In addition, a comparison between our analytical result and Langmuir-Blodgett law shows that the physics approximation method is valid in nonlinear differential equation analysis and can be used in other similar cases. Applying the approximation method, we get the relativistic theory corrected current for 1-D cylindrical diodes.

Conferences

Surface flashover across ceramic disks in vacuum at cryogenic temperatures

Authors: H. Keene; J. Dickens; A. Neuber; H. Krompholz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1277716

Abstract: As superconducting technology becomes more viable in the marketplace, especially in high power applications, the need for a well researched high thermal conductivity electrical insulator is needed. The electrical failure mode for these types of insulators is often surface flashover at subatmospheric temperature and pressure. Testing of two such insulators, aluminum nitride and aluminum oxide, for this failure mode is done for two differing electrode geometries. In addition three coats of GE 7031 dielectric varnish are applied to the exposed parts of the insulator for comparison testing with nonvarnished samples. In general the testing shows an increasing breakdown voltage trend with decreasing temperature. These results indicate a temperature related dependence of the secondary electron emission and electron induced outgassing, which is a component in the process of surface flashover. The addition of the varnish results in a lowered breakdown voltage. The research also covers the effect of electrode conditioning, and presents optical diagnostics of the gas species involved during breakdown.

IEEE Conferences

Thermal Deformation Noise In Large Optical Systems

Authors: Tolomeo, J; Klavins, A; Tenerelli, D; Dickens, J

PDF: https://aip.scitation.org/doi/10.1063/1.1622770

Abstract: Future large space-based telescope systems require precise optical surface quality and wave-front stability. One source of noise for very large precise optical systems is ambient thermal energy which induces statistical fluctuations in the strain energy state of the structure. We broadly model such optical systems as bending energy dominated or membrane in-plane energy dominated and derive analytical expressions for the governing parameters that determine noise magnitude. It is shown that for bending-based systems thermal noise increases as aperture is increased and as bending stiffness is decreased, while for membrane mirror systems it is the in-plane pretension level that determines the noise magnitude. The analysis is extended to numerical finite element techniques to illustrate the effects on very general large damped structures where we address the form of equivalent thermal loading density required in modeling such distributed structures. Calculations show that temporal rms deformation noise on the order of a picometer or less can be expected for apertures up to about 10 m and therefore is probably not significant. For lightweight precision aperture systems greater than 10 m, thermal noise may need to be considered in the design. (C) 2003 American Institute of Physics.

Journal

2002

Compact Explosive-Driven Generator Of Primary Power Based On A Longitudinal Shock Wave Demagnetization Of Hard Ferri- And Ferromagnets

Authors: Shkuratov, SI; Talantsev, EF; Dickens, JC; Kristiansen, M

PDF: https://www.researchgate.net/publication/3165387_Compact_explosive-driven_generator_of_primary_power_based_on_a_longitudinal_shock_wave_demagnetization_of_hard_ferri-_and_ferromagnets

Abstract: A new type of compact explosive-driven generator of primary power, which utilizes phenomena of a shock-wave demagnetization of hard ferri- and Mirromagnets, was developed. The shock wave initiated by high explosive, as well as accelerated flyer plate, passes along the hard ferri- or ferromagnetic body, which serves as initial energy carrier. The shock wave demagnetizes the energy-carrying element, reducing the initial magnetic flux Phi(0). In accordance with Faraday's law, this change of magnetic flux DeltaPhi(0) generates an electromotive force in, a coil wound on the energy carrier. Several types of compact generators with energy-carrying element of 10 cm(3) in volume were explored. High-voltage generators that utilize energy of BaFe12O19 hard ferrimagnets are capable of producing pulses of amplitude 5.5 kV with full width at half maximum (FWHM) of 1 mus. The generators that utilize energy of Nd2Fe14B high-energy hard ferromagnets are capable of producing pulses with amplitude more than 10 kV and FWHM about 4 mus. The high-current generators based on Nd2Fe14B produced pulses yielded 826 A and FWHM of 180 mus. The developed generator can be used as the most reliable and effective source of primary power capable of seeding magnitocumulative generators.

Journal

Dependence of flux losses on MCG helix geometry

Authors: Andreas A. Neuber; Thomas Holt; Juan-Carlos Hernandez; James C. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6219386

Abstract: While Magneto Cumulative Generators (MCGs) differ widely in size and operating regimes, it is apparent that the helical flux compression generator is the most promising concept with respect to current amplification and compactness. Though the geometry of the helical generator (dynamically expanding armature in the center of a current carrying helix) seems to be basic, it turns out that the understanding of all involved processes is rather difficult. This fact is apparent from the present lack of a computer model that would be solely based on physical principles and manage without heuristic factors. This means, all programs known to the authors utilize an additional parameter that adjusts for the loss in flux that is currently unexplained. Experimental efforts revealed that the unexplained loss in flux becomes smaller the larger the generator volume is. Specifically, for generators with constant diameter helix and armature, the figure of merit, β, for generator performance exhibits a distinct decline with the angular frequency, ω, of the progressing contact between end-initiated armature and helix. Since ω is proportional to the square root of the ratio of initial MCG inductance to compressed volume, it becomes apparent that the generator performance is limited by size. For large generators on a meter scale, a β of approximately 0.95 has been reported (β = 1 means no flux loss at all), and own tests indicate that β drops quickly to about 0.7 to 0.6 for generator on the 10 cm scale. Still, even very small generators with about 30 mm outer diameter can have a β of around 0.6. Tapered generators, with tapered helix or tapered armature might perform differently and can be used to further assess the situation. Preliminary results for MCGs with a tapered helix show a performance that is somewhat superior to the straight helix generator.

Conferences

Electric breakdown in liquid nitrogen

Authors: H. Krompholz; A. Neuber; M. Haustein; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1022721

Abstract: The phenomenology of breakdown in liquid nitrogen is investigated with high-speed electrical and optical diagnostics (temporal resolution down to several 100 ps). The discharge apparatus uses a cable discharge into a coaxial system with axial discharge, and a load line to simulate a matched terminating impedance. Main experiments are done in self-breakdown mode in supercooled liquid nitrogen. Transmission line type current sensors and capacitive voltage dividers with fast amplifiers/attenuators cover an amplitude range of 0.1 mA to 1 kA with a time resolution of 300 ps, providing complete information about discharge voltage and current. The light emission is measured with fast photomultiplier tubes (risetime 800 ps), and these optical measurements will be supplemented by high-speed photography and spectroscopic investigations on a nanosecond time scale. First results on self-breakdown with a gap width of 1 mm and electrodes with 5 mm radius of curvature (breakdown voltage 42 kV) show a three-phase development: the current rises from an unknown level to several mA during 2 ns, stays approximately constant for 100 ns with superimposed ns-duration spikes, and shows a final exponential rise to the full impedance limited current amplitude during several nanoseconds. Detailed optical and spectroscopic diagnostics along with the high-speed electrical diagnostics will in particular address the physical mechanisms initiating/assisting the liquid nitrogen volume breakdown, such as bubble formation during the pre-breakdown phase.

IEEE Conferences

Fast dielectric volume breakdown in liquid nitrogen

Authors: A. Neuber; H. Krompholz; M. Haustein; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1030428

Abstract: Summary form only given, as follows. Miniaturization of electrical components along with growing superconductor technology requires a better understanding of the phenomenology of breakdown in liquid nitrogen. It is known that the time delay between breakdown-onset and final impedance-limited arc current can occur within a few nanoseconds. For a temporal resolution down to several 100 ps, a discharge apparatus was built and tested that uses a cable discharge into a coaxial system with axial discharge, and a load line to simulate a matched terminating impedance. Main experiments are done in self-breakdown mode in supercooled liquid nitrogen, pulsed breakdown at high over-voltages in standard electrode geometry is investigated as well. Transmission line type current sensors and capacitive voltage dividers with fast amplifiers/attenuators cover an amplitude range of 0.1 mA to 1 kA with a time resolution of 300 ps, providing complete information about discharge voltage and current. The light emission is measured with fast photomultiplier tubes (risetime 800 ps), and these optical measurements will be supplemented by high-speed photography and spectroscopic investigations on a nanosecond time scale. Preliminary results on self-breakdown in the surface flashover mode with a gap width of 2 mm and electrodes with 5 mm radius of curvature (breakdown voltage /spl sim/ 60 kV) show a three-phase development: the current rises from an unknown level to several mA during 2 ns, stays approximately constant for 100 ns with superimposed ns-duration spikes, and shows a final exponential rise to the full impedance limited current amplitude during several nanoseconds. The detailed optical and spectroscopic diagnostics along with the high-speed electrical diagnostics will in particular address the physical mechanisms initiating/assisting the liquid nitrogen volume breakdown, such as bubble formation during the pre-breakdown phase.

IEEE Conferences

Feasibility study of an explosively formed transient antenna

Authors: A. Neuber; N. Schoeneberg; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1189493

Abstract: The feasibility of utilizing the chemical energy stored in high explosives to generate an antenna capable of radiating for several microseconds is studied. Crucial parameters such as conductivity as a function of time, maximum achievable antenna length for given initial device volume and weight, and material dependence are assessed by sub microsecond optical and electrical diagnostics. By utilizing a rotating framing mirror camera with up to 4 Megaframes per second, which produces a color image sequence consisting of 125 frames, possible premature breakup of the transient antenna rod is measured with adequate spatial and temporal resolution, thus revealing a rod growth velocity of a few millimeters/microsecond. Electrical diagnostic, primarily aimed at the conductivity between selected points along the rod propagation, enables to make a connection with the observed behavior based on the optical diagnostics. Maintaining electrical contact at the base of the device while the rod is fully formed is crucial and will be discussed in detail.

IEEE Conferences

High voltage, sub nanosecond feedthrough design for liquid breakdown studies

Authors: M. Cevallos; J. Dickens; A. Neuber; H. Krompholz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6219396

Abstract: Experiments in self-breakdown mode and pulsed breakdown at high over-voltages in standard electrode geometries are performed for liquids to gain a better understanding of their fundamental breakdown physics. Different liquids of interest include liquids such as super-cooled liquid nitrogen, oils, glycerols and water. A typical setup employs a discharge chamber with a cable discharge into a coaxial system with axial discharge, and a load line to simulate a matched terminating impedance, thus providing a sub-nanosecond response. This study is focused on the feed-through design of the coaxial cable into this type of discharge chamber, with the feed-through being the critical element with respect to maximum hold-off voltage. Diverse feedthroughs were designed and simulated using Maxwell 3-D Field Simulator Version 5. Several geometrically shaped feed-through transitions were simulated, including linearly and exponentially tapered, to minimize electrostatic fields, thus ensuring that the discharge occurs in the volume of interest and not between the inner and outer conductor at the transition from the insulation of the coaxial cable to the liquid. All feedthroughs are designed to match the incoming impedance of the coaxial cable. The size of the feedthroughs will vary from liquid to liquid in order to match the coaxial cable impedance of 50Ω. The discharge chamber has two main ports where the feed-through will enter the chamber. Each feed-through is built through a flange that covers the two main ports. This allows the use of the same discharge chamber for various liquids by changing the flanges on the main ports to match the particular liquid. The feedthroughs were designed and built to withstand voltages of up to 200 kV. The feedthroughs are also fitted with transmission line type current sensors and capacitive voltage dividers with fast amplifiers/attenuators in order to attain a complete range of information from amplitudes of 0.1mA to 1 kA with a temporal resolution of 300 ps.

IEEE Conferences

Liquid Nitrogen As Fast High Voltage Switching Medium

Authors: Dickens, J; Neuber, A; Haustein, M; Krile, J; Krompholz, H

PDF: https://aip.scitation.org/doi/10.1063/1.1530810

Abstract: Compact pulsed power systems require new switching technologies. For high voltages, liquid nitrogen seems to be a suitable switching medium, with high hold-off voltage, low dielectric constant, and no need for pressurized systems as in high pressure gas switches. The discharge behavior in liquid nitrogen, such as breakdown voltages, formative times, current rise as function of voltage, recovery, etc. are virtually unknown, however. The phenomenology of breakdown in liquid nitrogen is investigated with high speed (temporal resolution < I ns) electrical and optical diagnostics, in a coaxial system with 50-Ohm impedance. Discharge current and voltage are determined with transmission line type current sensors and capacitive voltage dividers. The discharge luminosity is measured with photomultiplier tubes. Preliminary results of self-breakdown investigations (gap I nun, breakdown voltage 44 kV, non-boiling supercooled nitrogen) show a fast (2 ns) transition from an unknown current level to several mA, a long-duration (100 ns) phase with constant current superimposed by ns-spikes, and a final fast transition to the impedance limited current during several nanoseconds. The optical measurements will be expanded toward spectroscopy and high speed photography with the aim of clarifying the overall breakdown mechanisms, including electronic initiation, bubble formation, bubble dynamics, and their role in breakdown, for different electrode geometries (different macroscopic field enhancements).

Conference Paper/Presentation

Microwave breakdown studies of He-N/sub 2/ mixtures in a pillbox cavity from 760 to 3040 torr

Authors: D. Hemmert; A. Neuber; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1189459

Abstract: Microwave breakdown of various He-N/sub 2/ mixture combinations is investigated utilizing an S-band double window pillbox cavity. The objective is to determine the best combination of the two gases to maximize the mixture's ability to cool a dielectric surface while maintaining high breakdown thresholds. Helium is known to be an excellent source to dissipate heat from a dielectric, but it also has a low microwave breakdown threshold. Nitrogen does not transport heat as well, but has a much higher breakdown threshold. The studies focused on generating a series of E-field vs pressure curves for breakdown to help identify optimum He-N/sub 2/ mixture ratios. The S-band double window pillbox has a 333 cm/sup 3/ cavity with two ports to flow the gas mixture through. The pillbox is placed in a traveling wave resonant ring (TWRR) coupled to a 2.85 GHz, 4 MW, magnetron. This combination of double window pillbox and TWRR allows for testing power levels up to 40 MW. High speed diagnostics are used to measure the incident/reflected power and discharge luminosity. Coupled mass flow controllers maintain the gas mixture ratio and continuous gas flow through the cavity. Investigations can be conducted with single or multiple pulsed operations. Results ranged from a minimum of 5 MW for pure helium at 760 torr, to greater than 40 MW for pure nitrogen at 3040 torr.

IEEE Conferences

Shock Wave Demagnetization Of Bafe12O19 Hard Ferrimagnetics

Authors: Shkuratov, SI; Talantsev, EF; Dickens, JC; Kristiansen, M

PDF: https://aip.scitation.org/doi/abs/10.1063/1.1431434

Abstract: A study of the effect of shock waves on the phase state of a hard ferrimagnetic material has been performed. A plane shock wave was passed along the axis of a cylindrical BaFe12O19 hard ferrite magnet. The shock wave demagnetized the cylinder, reducing the magnetic flux. This change in magnetic flux generated an electromotive force (EMF) in a coil wound around the ferrite. The value of the EMF calculated on the assumption that the ferrite was completely demagnetized by the shock wave is in good agreement with the peak EMF value obtained experimentally. (C) 2002 American Institute of Physics.

Journal

Single-shot, repetitive, and lifetime high-voltage testing of capacitors

Authors: S. I. Shkuratov; E. F. Talantsev; L. L. Hatfield; J. C. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1178233

Abstract: Four different types of capacitors have been tested to determine the maximum usable high voltage. Ceramic, drop-dipped film, molded-mylar tubulars, and polyester/foil capacitors of different values and different nominal voltages were tested in four modes: the single-shot mode, the repetitive mode, the lifetime dc voltage mode, and the group mode. Experiments have shown that the breakdown voltage for all types of the capacitors tested is ten to seventeen times higher than the nominal voltage. The energy stored in the capacitors for a short time under overstress conditions is from 100 to 250 times higher their normal energy. Data are given for the limitations for single capacitors, and for two, three, and four capacitors connected in parallel.

IEEE Journals

Subnanosecond corona inception in an ultrawideband environment

Authors: J. Mankowski; J. Dickens; M. Kristiansen; J. Lehr; W. Prather; J. Gaudet

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1158359

Abstract: Corona discharges in ultrawideband radiating systems can have adverse effects on performance such as reflection, phase dispersion, and significant power losses. A test-bed has been assembled to experimentally observe corona created by voltage pulses similar to ultrawideband systems. The current work involves the attenuation of an incident pulse after propagation through a self-initiated corona and relative measurements of visible light emission from the photoionization produced during streamer development. Several gas dielectrics, including ambient air, N/sub 2/, H/sub 2/, and SF/sub 6/, were tested.

IEEE Journals

The Conductivity Of A Longitudinal-Shock-Wave-Compressed Nd2Fe14B Hard Ferromagnetics

Authors: Talantsev, EF; Shkuratov, SI; Dickens, JC; Kristiansen, M

PDF: https://www.worldscientific.com/doi/abs/10.1142/S0217984902003956

Abstract: The conductivity of Nd2Fe14B hard ferromagnetic subjected to compression by a longitudinal shock wave (the shock wave propagates along the magnetization vector M) with a pressure of 35 GPa is measured. The results of the experiments show that the conductivity of the longitudinal-shock-wave-compressed Nd2Fe14B is sigma(sw) = (2.83 +/- 0.24)x 10(2) (Omega cm)(-1), which is 22 times lower than the conductivity of Nd2Fe14B under normal conditions.

Journal

The Current Mode Of Pulsed Power Generation In A Moving Magnet System

Authors: Shkuratov, SI; Talantsev, EF; Dickens, JC; Kristiansen, M; Hernandez, JC

PDF: https://ieeexplore.ieee.org/document/1178194

Abstract: Results of an experimental study of the generation of high-current pulses in a moving magnet system based on an open ferromagnetic circuit design are presented. The magnet was accelerated with the use of a light gas gun. Experimental data are given for the output high current pulses, output voltage, and power delivered in the load for different types of pulse-generating coils. The effect of various pulse-generating windings is given. It has been shown that the Nd2Fe14B hard ferromagnetic projectile (diameter 2.54 cm and height 1.9 cm) moving with a velocity of 320 m/s is capable to produce in the pulse-generating coil a current pulse with amplitude of 1.4 kA and a full-width at half-maximum 80 mus.

Journal

Transverse Shock Wave Demagnetization Of Nd2Fe14B High-Energy Hard Ferromagnetics

Authors: Shkuratov, SI; Talantsev, EF; Dickens, JC; Kristiansen, M

PDF: https://aip.scitation.org/doi/abs/10.1063/1.1480478

Abstract: The action of transverse shock waves (the shock wave propagates across the magnetization vector M) on the magnetic phase state of a Nd2Fe14B high-energy hard ferromagnetic was investigated experimentally. The design of the ferromagnetic sample, which was made as a hollow cylinder, has made it possible to dramatically reduce the amount of the explosive that initiates a transverse shock wave in Nd2Fe14B to 1.0 g (for Nd2Fe14B samples weighing 67.5 g). The results of the experiment have shown that the transverse shock wave propagating through Nd2Fe14B causes hard ferromagnetic-to-paramagnetic phase transformation terminating by practically complete demagnetization of Nd2Fe14B. Pulse generators based on the transverse shock wave demagnetization of hollow cylindrical Nd2Fe14B samples with diameter of 25.4 mm and length of 19.1 mm are capable of producing high-voltage pulses [peak voltage of 11.3 kV, full width at half maximum (FWHM) of 4.5 mus] and high-current pulses (peak current of 1.93 kA, FWHM of 100 mus, peak power of 27.0 kW). The effect of transverse shock wave demagnetization of high-energy hard ferromagnetic, Nd2Fe14B, was detected. (C) 2002 American Institute of Physics.

Journal

Ultracompact Explosive-Driven High-Current Source Of Primary Power Based On Shock Wave Demagnetization Of Nd2Fe14B Hard Ferromagnetics

Authors: Shkuratov, SI; Talantsev, EF; Dickens, JC; Kristiansen, M

PDF: https://aip.scitation.org/doi/10.1063/1.1487894

Abstract: A new type of explosive driven high-current pulsed source utilizing a shock wave demagnetization of a Nd2Fe14B hard ferromagnetic energy carrier was developed. The design of the ferromagnetic energy carrier, which was made a hollow cylinder, has made it possible to reduce dramatically to 1 g the amount of the explosive providing a complete demagnetization of Nd2Fe14B energy carrier of weight 64 g. The developed generator is capable of producing high-current [up to 1.9 kA, 100 mus full width at half maximum (FWHM)] and high-power pulses (up to 42 kW, 2.8 mus FWHM). (C) 2002 American Institute of Physics.

Journal

Volumetric segmentation via 3D active shape models

Authors: M. M. Dickens; S. S. Gleason; H. Sari-Sarraf

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=999927

Abstract: A volumetric image segmentation algorithm has been developed and implemented by extending a 2D algorithm based on active shape models. The new technique allows segmentation of 3D objects that are embedded within volumetric image data. The extension from 2D involved four components: landmarking, shape modeling, gray-level modeling, and segmentation. Algorithms and software tools have been implemented to allow a user to efficiently landmark a 3D object training set. Additional tools were built that subsequently,, generate models of 3D object shape and gray-level appearance based on this training data. An object segmentation strategy was implemented that optimizes these models to segment a previously unseen instance of the object. Results of this new 3D segmentation algorithm have been generated for a synthetic volumetric data set.

IEEE Conferences

2001

Calculation of air temperature and pressure history during the operation of a flux compression generator

Authors: Xiaobin Le; J. Rasty; A. Neuber; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1001693

Abstract: During the operation of magnetic flux compression generators (MFCG), the gas-plasma, shocked by the rapidly expanding armature, could lead to electrical arcing across the gas between the armature and the stator at locations where physical contact between the armature and stator has not yet occurred. This will result in a loss of magnetic flux and a decrease in the electrical efficiency of the MFCG. Therefore, knowledge of the ensuing gas temperature and pressure histories is necessary for identification of loss mechanisms in an effort to optimize the efficiency of MFCGs. This paper describes the procedure for estimating the air temperature and pressure histories via finite element (FE) simulation of the armature expansion and its ensuing contact with the stator in an MFCG. First, the validity of the FE model was verified by comparing deformation contours obtained from the simulations to those obtained experimentally via high-speed photography. Utilizing the pressure history data obtained from the FE results, the air temperature was theoretically calculated. The results indicate that the air pressure and temperature in an MFCG, having a compression ratio of 1.8, could be as high as 30 MPa and 4000/spl deg/ Kelvin, respectively.

IEEE Conferences

Compact explosive driven shock wave ferromagnetic generators

Authors: S. I. Shkuratov; E. F. Talantsev; M. Kristiansen; J. Dickens; J. C. Hernandez; A. Neuber

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1002017

Abstract: The results are presented of tests with compact, explosively driven shock wave ferromagnetic generators. The shock wave from a high explosive charge is passed along the axis of a cylindrical, hard magnet. Two types of permanent magnets were used in the experiments: rare-earth NdFeB cylinders (D = 2.5 cm, L = 1.9 cm) and hard ferrite BaFe/sub 2/O/sub 3/ cylinders (D = 2.2 cm, L = 2.5 cm). The shock wave demagnetizes the cylinder, reducing the flux from the remnant value to zero. This change in flux generates a voltage in the winding. The current generated in the loads of the generators yielded a peak of 0.75 kA. The operation of the shock wave ferromagnetic generators was analyzed by the Maxwell 3D code. An analysis is given on the specific features of pulse generation in a system like this.

IEEE Conferences

Conductivity measurements of MFCG armature material under shock and high strain rates utilizing a split-hopkinson pressure bar apparatus

Authors: D. Hemmert; J. Rasty; A. Neuber; J. Dickens; X. Le; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=1002043

Abstract: Modeling and characterization of a Magnetic Flux Compression Generator (MFCG) requires detailed knowledge of the changes in conductivity of the MFCG materials during the shock-loading phase. A Split-Hopkinson Pressure Bar apparatus (SHPB) and current source/ differential amplifier setup was used to study shock-loading under controlled conditions while monitoring changes in resistivity in armature material samples. The SHPB apparatus was capable of producing strain rates up to the fracture limit of the samples tested. Actual fracturing of samples would not have allowed detailed analysis of thermal and mechanical effects in sample resistivity changes. Sample strain rate levels of up to lx104 strain sec-1 were achieved with the apparatus on OFHC copper and aluminum samples.

Conferences

Effect of electron-beam pulse length on microwave efficiency of coaxial vircator

Authors: W. Jiaig; K. Woolverton; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1001883

Abstract: The coaxial virtual cathode oscillator (vircator) at Texas Tech University was studied by varying the pulse length of the electron beam. Previous experimental results obtained with electron beam pulse width of 25 ns have indicated that the microwave output power had not saturated before the electron beam power terminated. Therefore, it has been expected that the maximum microwave power can be increased if the electron beam pulse is lengthened. Experiments were carried out with the electron-beam pulse length of 25 ns and 70 ns, respectively, while keeping other parameters the same. The microwave outputs obtained with different electron-beam pulse lengths are compared in order to understand the effect of the pulse length on the microwave efficiency of the coaxial vircator.

IEEE Conferences

Electrical behavior of a simple helical flux compression generator for code benchmarking

Authors: A. Neuber; J. Dickens; J. B. Cornette; K. Jamison; E. R. Parkinson; M. Giesselmann; P. Worsey; J. Baird; M. Schmidt; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=940950

Abstract: A variety of basic magnetic flux compression (MFC) generator geometries have been tested during the last three decades. Though size and operating regimes differ widely, it is apparent that the helical flux compression generator is the most promising concept with respect to current amplification and compactness. Though the geometry of the helical generator (dynamically expanding armature in the center of a current carrying helix) seems to be basic, it turns out that the understanding of all involved processes is rather difficult. This fact is apparent from the present lack of a computer model that is solely based on physical principles and manages without heuristic factors. A simple generator was designed to address flux and current losses of the helical generator. The generator's maximum current amplitude is given as a function of the seed current and the resulting "seed-current" spread is compared to the output of state-of-the-art computer models. Temporally resolved current and current time derivative signals are compared as well. The detailed generator geometry is introduced in order to facilitate future computer code bench marking or development. The impact of this research on the present understanding of magnetic flux losses in helical MFC generators is briefly discussed.

IEEE Journals

Experimental and numerical investigation of the armature/stator contact in magnetic flux compression generators

Authors: J. Rasty; X. Le; A. Neuber; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=960712

Abstract: Summary form only given, as follows.The ability of MFCGs for creating large current pulses is well accepted among the scientific community; however, little is understood regarding the fundamental mechanical and electrical mechanisms, and their interrelationship, governing the operation and efficiency of MFCGs. The main objective of this research was to conduct a series of experimental and numerical studies in an attempt to gain insight into the inner working of MFCGs. As a first step, the expansion characteristic of the exploding armature was selected as one of the major factors affecting the efficiency of MFCGs. Both numerical as well as experimental techniques were employed to capture the explosive-driven expansion behavior of the armature. Numerical results were verified experimentally to determine the expansion-time history, expansion angle, expansion velocity, armature/stator contact velocity and the severity of the end-effect in a typical MFCG. The experimental and numerical results showed excellent agreement paving the way for future simulations using the established FE model. The results indicate that the radial and axial impact velocities between the armature and the stator are almost constant throughout the operation of MFCG. Moreover, the results indicate that the contact velocity between the armature decreases as the post-detonation time increases, reaching a constant value equal to the detonation velocity.

IEEE Conferences

Experimental study of compact explosive-driven shock wave ferroelectric generators

Authors: S. Shkuratov; M. Kristiansen; J. Dickens; A. Neuber; L. L. Altgilbers; P. T. Tracy; Y. Tkach

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=960832

Abstract: Summary form only given. The design of shock wave ferroelectric generators driven by high explosives is presented and experimental data are discussed. The active elements are lead zirconium titanate (PZT) disks with diameter D=25 mm and thickness L=2.5 mm, and PZT cylinders with D=21 mm and L=25 mm. The high explosive charge was varied from 4.2 g to 30 g. Two different ways to initiate shock waves in the active elements were used: explosively driven flyer plates and direct action of high explosives. The data are presented on the maximum power released in the resistive load and on the effect of the load inductance and the load capacitance on the amplitude of the pulse produced. The experimental results are discussed in comparison to numerical simulation with the commercial circuit simulator PSPICE. An analysis is given of the specific features of pulse generation in a system like this.

IEEE Conferences

Explosive driven ferroelectric generators

Authors: Y. Tkach; S. Shkuratov; L. Dickens; V. Kristiansen; L. L. Altgilbers; P. T. Tracy

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1001707

Abstract: Explosive driven ferroelectric generators (EDFEGs) are compact power sources that have been considered for use as seed sources for magnetocumulative generators, as well as prime power sources. Shock waves generated by high explosives are used to shock depolarize ferroelectric materials, which results in a voltage pulse being delivered to a load. These generators have been experimentally investigated at Texas Tech University. Data from these experiments was used to benchmark a code developed at the Institute of Electromagnetic Research. In this paper, a description of the simulation and a comparison of the experimental and simulation results are presented.

IEEE Conferences

Explosive-Driven Moving Magnet Generators

Authors: Shkuratov, SI; Kristiansen, M; Dickens, J

PDF: https://ieeexplore.ieee.org/document/1001700

Abstract: The results are presented of experimental studies of explosively driven moving magnet generators. The study was performed with the use of high explosive and propellant charge. The projectiles used were NdFeB cylinders with D = 2.5 cm and H = 1.9 cm. Data are given for amplitude of high current pulses for different designs of the devices. The experiments performed have shown that the best option for generators using a moving magnetic projectile is to utilize the energy of the gases formed as a result of burning of the explosive rather than the energy of a flyer plate accelerated under the action of burning of the explosive. The explosive of preference is not C-4, but a military propellent charge which shows a high burning velocity and a high energy of explosive gases.

Conference Paper/Presentation

High Current Testing Of Batteries

Authors: Shkuratov, SI; Kristiansen, M; Dickens, J; Horrocks, E

PDF: https://ieeexplore.ieee.org/document/1001860

Abstract: Different types of commercial batteries were tested in a high-current mode to determine which is the best in portable pulsed power applications. The testing of the batteries was performed in two regimes: short time regime (one second) and long time regime (one hundred seconds). Alkaline, carbon, lithium, lithium ion, lead acid and nickel cadmium batteries of different dimensions have been tested to determine the maximum usable power for short and long time modes. The resistance of the load was varied from 1 Omega to 22 mOmega. Current-voltage characteristics are presented for sixteen different types of batteries. Data are given for maximum power per unit of weight and per unit of volume.Different types of commercial batteries were tested in a high-current mode to determine which is the best in portable pulsed power applications. The testing of the batteries was performed in two regimes: short time regime (one second) and long time regime (one hundred seconds). Alkaline, carbon, lithium, lithium ion, lead acid and nickel cadmium batteries of different dimensions have been tested to determine the maximum usable power for short and long time modes. The resistance of the load was varied from 1 Omega to 22 mOmega. Current-voltage characteristics are presented for sixteen different types of batteries. Data are given for maximum power per unit of weight and per unit of volume.

Conference Paper/Presentation

High voltage testing of capacitors

Authors: S. I. Shkuratov; E. F. Talantsev; M. Kristiansen; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1001859

Abstract: Three different types of capacitor have been tested to determine maximum usable high voltage. The capacitor testing was performed in the dynamic mode. The voltage rise varied from 200 to 400 V/sec. Disc ceramic and thin film capacitors of different value and different nominal voltages were tested. Experiments have shown that the breakdown voltage for all types of the capacitors tested is about ten times more than the nominal voltage of the capacitors. Data are given for the limiting high voltage for each kind of capacitor. Experiments have shown that the mechanisms for the destruction of each type of capacitor have specific features.

IEEE Conferences

Impact of helix geometry on MCG flux losses [magneto cumulative generators]

Authors: T. Holt; A. Neuber; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1001684

Abstract: Explosively driven magnetic flux compression has been the object of research for more than three decades. Recently heightened interest has been focused on the basic physical mechanisms that determine the performance of helical magneto cumulative generators (MCGs). Two single-pitch helical flux compression generators of different sizes have been tested using current-voltage probes and optical diagnostics. The main parameters used to characterize the experimental performance of the flux compression generators were the flux conservation and theoretical current gain of each type of generator. Helices with constant pitch and differing separation between wires as well as wires with different insulation thickness were tested and analyzed with respect to their flux conservation and theoretical current gain. Preliminary results show that the insulation thickness plays only a minor role for a change in flux conservation due to geometry in the range from 0.01 to 0.5 mm provided that no internal breakdown occurred. Additionally, the overall physical dimension of the generator was modified to allow for a substantial increase in initial inductance. The outer diameter of the generator armature was held constant at 1.5 inches and the coil diameter was varied from 2.6 to 3.5 inches (expansion ratio of 1.7 or 2.3, respectively). The results gained from the conservative expansion ratio of 1.7 were used as a base to compare to the generator performance at the more aggressive expansion ratio of 2.3. First results show that an expansion ratio of 2.3 produces viable results for a partially annealed Aluminum armature with a Gurney angle of approximately 15 degrees.

IEEE Conferences

Parametric and experimental investigation of the EDFEG

Authors: Y. Tkach; S. Shkuratov; J. Dickens; M. Kristiansen; L. L. Altgilbers; P. T. Tracy

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1001708

Abstract: The objective of this work was to investigate both parametrically and experimentally the properties of the explosive driven ferroelectric generator (EDFEG). The parametric investigaton was conducted using a simulation developed by the Institute of Electromagnetic Research and the experimental investigation using the explosive test facilities at Texas Tech University. Both efforts were conducted synergistically in order to fully understand the characteristics of the EDFEG and to optimize its operation. Results of both studies are presented.

IEEE Conferences

The Current Mode Of Pulsed Power Generation In Moving Magnet Systems

Authors: Shkuratov, SI; Kristiansen, M; Dickens, J; Hernandez, JC

PDF: https://ieeexplore.ieee.org/document/1001701

Abstract: Results are presented of investigations of the generation of high-current pulses in moving magnet generators designed as an open ferromagnetic circuit. The experimental study was performed with the use of a light gas gun. The magnetic projectiles were ferromagnetic cylinders having 2.54-cm diameters. Data are given for the amplitude of high current pulses and power in the load for different designs of the devices, the effect of various windings on the pulse-generating coils, and different types of loads. It has been shown that with velocities of the magnetic projectiles of 200-300 m/s, the peak current of the pulses produced by the generators reach kiloamperes.

Conference Paper/Presentation

Thermodynamic state of the magnetic flux compression generator volume

Authors: A. Neuber; T. Holt; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=1002003

Abstract: The knowledge of the thermodynamic state of the gas trapped in a helical flux compression generator is crucial for the assessment of flux loss due to internal electrical breakdown/arcing. Besides the helix deformation and armature deceleration at extremely high current amplitudes approaching 1 MA, the thermodynamic state of the shocked and compressed gas causes problems in the prediction of the generator output current vs. time towards the end of generator operation. Such a breakdown is experimentally detected as an abrupt change in the time derivative of the current waveform and it is easily distinguished from partial turn skipping by its sharper fall and nonperiodic occurrence. The thermodynamic state of the generator was measured using primarily optical emission spectroscopy. Three main stages of operation are discussed: (1) the initial stage, which can be represented by a freely expanding armature, that shows fairly low gas temperatures; possibly as low as 2000 K; and (2) the intermediate stage during 14 to 4 microseconds before generator burnout that exhibits mainly an atomic copper line transition at about 0.8 eV; and (3) the last few microseconds that reveal a highly compressed gas with temperatures of about 5000 K and pressures of about 1500 bar. Most experiments were conducted in air, initially at STP, some results are given for SF/sub 6/ initially at one atmosphere. In order to link the thermodynamic state to the breakdown sensitivity, additionally, simple conductivity measurements were conducted in current-free flux compression generator models.

IEEE Conferences

2000

Dielectric/gas interface breakdown caused by high power microwaves

Authors: D. Hemmert; A. Neuber; J. Dickens; H. Krompholz; L. L. Hatfield; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6220112

Abstract: Physical mechanisms leading to microwave breakdown on dielectric/gas interfaces are investigated for power density on the order of 10 MW/cm2 at 2.85 GHz and gas pressures on the order of 10−4 torr to 103 torr. The investigation is focused on an alumina/air interface; other gases are considered for reference purposes. A 3 MW magnetron with 3.5 µs pulse width is coupled to an S-band traveling wave resonator with a pressure adjustable test region. The pre-breakdown phase and the breakdown are monitored by recording the traveling and reflected power, and the spatially integrated luminosity. Electric field probes in the vicinity of the interface are included as well to get information about the local field. Furthermore, the light emission was observed with an image intensifier capable of a minimum gate time of 2.5 ns, in temporal correlation to the other phenomena, or with a framing camera having a 20 ns gate time and 100 ns separation between pictures. The pressure dependent breakdown characteristics, such as appearance, breakdown field, and temporal shape of electric signals, are compared to dielectric/vacuum interface breakdown and volume breakdown, all measured utilizing similar setups.

IEEE Conferences

Experimental and analytical investigation of a pulsed power conditioning system for magnetic flux compression generators

Authors: M. Giesselmann; T. Heeren; E. Kristiansen; J. G. Kim; J. C. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=901200

Abstract: The pulsed power conditioning system (PPCS) is one of the key enabling technologies for using the energy output of a magnetic flux compression generator (MFCG). This paper shows the results of comprehensive experimental studies of an inductive energy storage system using an exploding wire fuse. The effects of metal oxide varistors (MOVs) for use as pulse-shaping devices are also presented. The experimental results are complemented by a comprehensive evaluation and interpretation of the results using the tools available in the professional version of MathCAD.

IEEE Journals

Fundamental studies of a helical magnetic flux compression generator

Authors: A. Neuber; J. Dickens; M. Giesselmann; B. Freeman; D. Dorsey; H. Krompholz; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6220176

Abstract: The design of a helical flux compression generator, driven by 200 g of high explosives, for basic studies is presented and experimental results are discussed. Generator current and dI/dt are measured with Rogowski coils placed on the load. Both crowbar closure and contact velocity have been successfully simulated with CTH, a three-dimensional finite element hydrodynamic code. The generator's magnetic field structure is briefly discussed and magnetic field probe measurements are presented.

IEEE Conferences

Fundamental studies of a simple helical magnetic flux compression generator

Authors: A. Neuber; J. Dickens; M. Giesselmann; B. Freeman; J. Rasty; H. Krompholz; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=855148

Abstract: Summary form only given, as follows. The design of a helical flux compression generator, driven by 150 g of high explosives, for basic studies is presented and experimental results are discussed in comparison to numerical simulations. Simulation of the electric current output with the commercial circuit simulator PSPICE shows that this generator conserves the magnetic flux ideally in the low current mode, <30 kA. At current amplitudes in excess of 100 kA heating and melting of the single wound helix wire, AWG 12, limit the current flow. The volume between armature and stator is spectroscopically probed with fiber optics and valuable insight into the state of the shocked and compressed gas is gained. The same fiber optic probes are used to measure the velocity of the armature-stator contact along the generator axis. This contact velocity is largely affected by armature end effects, mainly due to the pressure loss at the detonator end. Both gas temperature and contact velocity have been successfully simulated with LS-DYNA3D, a three dimensional finite element hydrodynamic code. The generator's magnetic field structure is briefly discussed and magnetic field probe measurements are presented.

IEEE Conferences

High Power Microwave Window Breakdown Under Vacuum And Atmospheric Conditions

Authors: Hemmert, D; Neuber, AA; Dickens, JC; Krompholz, H; Hatfield, LL; Kristiansen, M

PDF: https://spie.org/Publications/Proceedings/Paper/10.1117/12.391818?SSO=1

Abstract: Microwave window breakdown is investigated in vacuum and atmospheric conditions. An S-band resonant ring with a frequency of 2.85 GHz and a power of 80 MW with a 4 MW magnetron as a source is used. Window breakdown on the vacuum side is simulated using a dielectric slab partially filling an evacuated waveguide. Various high-speed diagnostic methods yield a complete picture on the breakdown phenomenology, with far reaching similarities to de surface flashover. During the initiation phase, free electrons are present, which can be influenced by magnetic fields, followed by a saturated secondary electron avalanche with electron-induced outgassing. Final breakdown occurs in the desorbed gas layer above the surface. In order to simulate window breakdown on the gas-side, a segment of the resonant ring separated by two windows was filled with gas at variable pressure, and breakdown was initiated by field-enhancement tips on one of the gas-side surfaces. Threshold power densities for breakdown are measured, and first results on the phenomenology of this gas breakdown are compared with the processes of flashover in vacuum.

Conference Paper/Presentation

High power microwave generation by a coaxial vircator

Authors: W. Jiang; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=6220043

Abstract: A coaxial-type virtual cathode oscillator (vircator) was tested in the Pulsed Power Laboratory at Texas Tech University with electron beam parameters of 500 kV, 40 kA, and 30 ns. The major goal of this experiment was to understand the characteristics of the coaxial vircator and the effect of the feedback field on the microwave efficiency. The experimental results have given the output microwave power of ∼ 400 MW, the microwave energy efficiency of ∼ 2 %, the microwave frequency of ∼ 2 GHz, and the microwave mode of TE11 in circular waveguide. By enhancing the field intensity around the vircator using a microwave reflector, the microwave output power was increased to ∼ 900 MW giving microwave energy efficiency of ∼ 5.5 %. This efficiency is calculated as peak microwave power divided by peak beam power, which does not occur at the same time. The instantaneous efficiency, using the beam power at the time of the peak microwave power is 20%.

IEEE Conferences

High-Current And High-Voltage Pulsed Testing Of Resistors

Authors: Shkuratov, SI; Kristiansen, M; Dickens, JC; Hatfield, LL; Horrocks, E

PDF: https://ieeexplore.ieee.org/document/901242

Abstract: Three types of resistors have been tested to determine maximum usable power at pulsed high,voltage and pulsed high current. Experiments ere carried out using high-voltage cable generators, spark-gap generators, and thyratron drivers, Pulse durations were varied from 0.7 mus to 21 mus The pulse amplitudes were varied from 1 kV to 35 kV. The peak cm rent reached was 3 kA. Metal him, carbon film, and carbon composition resistors of four different rated powers (0.25 W, 0.5 W, 1 W, and 2 W) have been tested. Data are given for the limiting pulsed power and energy for each type of resistor in nanosecond and microsecond time ranges. The experimental investigation of the threshold loading of the resistors in the high-current pulsed mode and in the high-voltage pulsed mode has shown that the process of destruction of resistors has specific features for each mode. The mechanisms of failure and destruction of resistors under the action of high-voltage and high-current pulses are discussed.

Journal

Microwave magnetic field effects on high-power microwave window breakdown

Authors: D. Hemmert; A. A. Neuber; J. Dickens; H. Krompholz; L. L. Hatfield; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=887650

Abstract: Microwave window breakdown in vacuum is investigated for an idealized geometry, where a dielectric slab is located in the center of a rectangular waveguide with its normal parallel to the microwave direction of propagation. An S-band resonant ring with a frequency of 2.85 GHz and a power of 60 MW is used. With field enhancement tips at the edges of the dielectric slab, the threshold power for breakdown is observed to be dependent on the direction of the microwaves; i.e., it is approximately 20% higher for the downstream side of the slab than it is for the upstream side. Simple trajectory calculations of secondary electrons in an RF field show a significant forward motion of electrons parallel to the direction of microwave propagation. Electrons participating in a saturated secondary avalanche on the upstream side are driven into the surface, and electrons on the downstream side are driven off the surface, because of the influence of the microwave magnetic field. In agreement with the standard model of dielectric surface flashover for dc conditions (saturated avalanche and electron-induced outgassing), the corresponding change in the surface charge density is expected to be proportional to the applied breakdown threshold electric field parallel to the surface.

IEEE Journals

Optical Diagnostics On Helical Flux Compression Generators

Authors: Neuber, AA; Dickens, JC; Krompholz, H; Schmidt, MFC; Baird, J; Worsey, PN; Kristiansen, M

PDF: https://ieeexplore.ieee.org/document/823591

Abstract: Explosively driven magnetic flux compression (MFC) has been object of research for more than three decades, Actual interest in the basic physical picture of flux compression has been heightened by a newly started Department of Defense (DoD) Multi-University Research Initiative. The emphasis is on helical flux compression generators comprising a hollow cylindrical metal liner filled with high explosives and at least one helical coil surrounding the liner. After the application of a seed current, magnetic flux is trapped and high current is generated by moving, i.e., expanding, the liner explosively along the finding of the helical coil, Several key factors involved in the temporal development can be addresses by optical diagnostics. 1) The uniformity of liner expansion is captured by framing camera photography and supplemented by laser illuminated high spatial and temporal resolution imaging. Also, S-ray flash photography is insensitive to possible image blur by shockwaves coming from the exploding liner, 2) The thermodynamic state of the shocked gas is assessed by spatially and temporally resolved emission spectroscopy, 3) The moving liner-coil contact point is a possible source of high electric Losses and is preferentially monitored also by emission spectroscopy, Since optical access to the region between liner and coil is not always guaranteed, optical fibers can be used to extract light from the generator. The information so gained will give, together with detailed electrical diagnostics, more insight in the physical loss mechanisms involved in MFC.

Journal

Pulsed generator based on shock demagnetization of ferromagnetic material

Authors: S. I. Shkuratov; M. Kristiansen; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=855151

Abstract: Summary form only given. The design of an explosive-to-electric transducer that uses the remnant magnetization in ferromagnetic cylinders is presented. 10-25 g charge of high explosives was used. The active element was NdFeB cylinders with diameter 2.5 cm and length 1.9 cm. The current generated in the low-resistance load of the generator yielded a peak 0.4 kA. Results of simulation of an explosive-to-electric transducer by Maxwell 3D code is presented. A detail analysis is given on the specific features of pulse generation in a system like this.

IEEE Conferences

Pulsed power generation using open and closed ferromagnetic circuits

Authors: S. I. Shkuratov; M. Kristiansen; J. C. Dickens; L. L. Hatfield; R. Martin

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=901196

Abstract: Results are presented of an experimental study of the generation of high-voltage and high-current pulses in generators designed as open and closed ferromagnetic circuits. Experiments were carried out using a light gas gun system. The magnetic projectiles were composed of ferromagnetic disks having 1.27- and 2.54-cm diameters. It has been shown that with velocities of the magnetic projectiles of 200-380 m/s, the peak voltage of the pulses produced by the generators reach several tens of kilovolts, peak current reaches kiloampere, and the energy delivered at the load is a few Joules. Generating modules connected in series will make it possible to produce a high-energy pulse with a peak voltage of a few hundred kilovolts. It has been shown that a closed ferromagnetic circuit generator is capable of generating not only single high-voltage pulses, but also repetitive oscillations. Data are given for the effects on the amplitude of high-voltage pulses caused by the length and velocity of the ferromagnetic projectiles and the design of the generating unit for both high-voltage and high-current modes of pulsed power generation.

IEEE Journals

Rapid decontamination of large surface areas

Authors: L. C. Farrar; D. P. Haack; S. E. McGrath; J. C. Dickens; E. A. O'Hair; J. A. Fralick

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=842896

Abstract: The effectiveness of the decontamination of biological agents (spores) on surfaces by two thermal plasma systems is reported. Using existing systems, operating at nonoptimum conditions, a steam plasma decontaminated surfaces at a maximum speed of 1.4 mph and a nitrogen plasma decontaminated at a maximum of 2.4 mph.

IEEE Journals

1999

Efficiency Enhancement Of A Coaxial Virtual Cathode Oscillator

Authors: Jiang, WH; Dickens, J; Kristiansen, M

PDF: https://ieeexplore.ieee.org/document/799837

Abstract: The microwave field intensity around the virtual cathode oscillator was enhanced by using a microwave reflector in the output waveguide. The experimental results show that the microwave output power strongly depends on the position and geometry of the microwave reflector. The maximum microwave efficiency obtained was twice as large as that without field enhancement by the microwave reflector.

Journal

Energy efficiency analysis of an inductive storage system

Authors: J. Kim; J. Zhang; M. Giesselmann; J. Dickens; J. Mankowski; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=823802

Abstract: In this paper, the simulation and evaluation of energy efficiency and voltage amplification in an inductive energy storage system with resistive, capacitive and diode loads is presented. A numerical simulation with Mathcad shows that by proper reduction of the storage energy inductance and of the exploding fuse interruption time, the energy efficiency and voltage amplification can be greatly improved.

IEEE Conferences

High Voltage Subnanosecond Corona Inception

Authors: J. Mankowski; J. Dickens; M. Kristiansen; J. Lehr; W. Prather; J. Gaudet

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=829276

Abstract: Summary form only as given.

IEEE Conferences

High power microwave generation by a coaxial virtual cathode oscillator

Authors: W. Jiang; K. Woolverton; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=799836

Abstract: A new type of virtual cathode oscillator, the coaxial vircator, was studied analytically and experimentally. A one-dimensional analytical model was used to describe the steady-state behavior of the electron beam and the virtual cathode, from which the diode current, the space-charge limited current, the virtual cathode position, and the estimated oscillation frequency were obtained. The experiments were carried out with typical electron-beam parameters of 500 kV, 40 kA, and 30 ns, where pulsed microwaves of 400 MW in peak power and 2 GHz in frequency have been obtained. The energy efficiency from the electron beam to microwaves was /spl sim/2%. This efficiency is expected to be improved by increasing the microwave field strength around the vircator.

IEEE Journals

Imaging of high-power microwave-induced surface flashover

Authors: A. Neuber; D. Hemmert; J. Dickens; H. Krompholz; L. L. Hatfield; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=763092

Abstract: Using two gated intensified digital charge-coupled device cameras, one sensitive in the near infrared to ultraviolet region and one in the soft X-ray region, the temporal development of high-power microwave-induced surface flashover across a vacuum/dielectric interface has been imaged. The emission of X-ray radiation from the interface is caused by field emitted electrons accelerated in the high electromagnetic field impacting the solid. This generation of bremsstrahlung terminates at the moment of full flashover development that is indicated by the optical light emission. A rising plasma density above the dielectric surface due to electron induced outgassing triggers this behavior.

IEEE Journals

Influence of the microwave magnetic field on high power microwave window breakdown

Authors: D. Hemmert; A. Neuber; J. Dickens; H. Krompholz; L. L. Hatfield; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=829539

Abstract: Summary form only given. Effects of the microwave magnetic field on window breakdown are investigated at the upstream and downstream side of a dielectric interface. Simple trajectory calculations of secondary electrons in an RF field show significant forward motion of electrons parallel to the microwave direction of propagation. The Lorentz-force due to the microwave magnetic field on high-energy secondary electrons might substantially influence the standard multipactor mechanism. As a result, the breakdown power level for the downstream side of a window would be higher than for the upstream side. This hypothesis was tested utilizing an S-band traveling wave resonant ring, powered by a 3 MW magnetron at 2.85 GHz, leading to a total power greater than 60 MW. Breakdown was studied on an interface geometry consisting of a thin alumina slab in the waveguide, oriented normal to the microwave propagation direction.

IEEE Conferences

Measurement of dynamic electrical conductivity of MFCG armature material under conditions of shock and high strain rate loading

Authors: J. Rasty; Xiaobin Le; A. Neuber; Jiande Zhang; J. Dickens

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=823611

Abstract: Characterization of changes in the conductivity during the shock loading process is of paramount importance in estimating the efficiency of magnetic flux compression generators (MFCG). In this study, the main emphasis was the characterization of dynamic conductivity of the armature material during the shock-loading phase. A Split Hopkinson Pressure Bar apparatus was utilized to subject as-received and annealed specimens of OFHC copper to various shock pressures. Experiments conducted to measure the resistivity of Cu specimens indicated that resistivity initially decreases, followed by a sharp increase before decreasing to a steady state value. Depending on the magnitude of the shock pressure, resistivity changes in excess of 200% were recorded.

IEEE Conferences

Optimization of Microwave Generation by Coaxial Vircator

Authors: W. Jiang; K. Woolverton; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=829727

Abstract: Summary form only as given.

IEEE Conferences

Pulse power conditioning with a transformer for an inductive energy storage system

Authors: M. Giesselmann; J. Zhang; T. Heeren; E. Kristiansen; J. Dickens; D. Castro; D. Garcia; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=823810

Abstract: One of the key technologies in a high power microwave system is the pulsed power conditioning system (PPCS). For a system driven by an explosive flux compression generator, the PPCS may consist of an energy storage inductor, a fuse type opening switch and a sharpening spark gap. This paper presents the investigation of a PPCS with a pulse transformer. Before the construction of a prototype, the behavior of the PPCS was simulated using the PSpice circuit simulation code. A transformer with a primary inductance of 3.5 /spl mu/H, secondary inductance of 85 /spl mu/H and coupling coefficient of 0.75, was designed and used in the experiments. The transformer was designed with two coaxial windings. Simulation results as well as experimental waveforms are shown.

IEEE Conferences

Pulsed power generation using ferromagnetic circuits

Authors: S. I. Shkuratov; M. Kristiansen; J. Dickens; L. L. Hatfield; R. Martin

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=823613

Abstract: Results are presented of an experimental study of the generation of high-voltage pulses in generators designed as open and closed ferromagnetic circuits. Experiments were carried out using a light gas gun system. The magnetic projectiles were composed of NdFeB discs having 1.27 and 2.54-cm diameters. Data are given for the effects on the amplitude of high voltage pulses by the length and velocity of the ferromagnetic projectiles and the design of the generating unit for both high voltage and high current modes of pulsed power generation. A detailed analysis is presented on the specific features of pulse power generators using open and closed ferromagnetic circuits. Fundamental limitations due to the physical processes occurring in systems like these are determined.

IEEE Conferences

Pulsed, high energy testing of resistors

Authors: S. I. Shkuratov; M. Kristiansen; J. Dickens; L. L. Hatfield; E. Horrocks

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=823612

Abstract: Three types of resistors have been tested to determine maximum usable power at pulsed high voltage and pulsed high current. Experiments were carried out using high voltage cable generators and spark-gap generators. Pulse durations were varied from 0.7 /spl mu/s to 21 /spl mu/s. The pulse amplitudes were varied from 1 kV to 12 kV. The peak current reached was 3 kA. Metal film, carbon film and carbon composition resistors of four different rated powers (0.25 W, 0.5 W, 1 W, 2 W) have been tested. Data are given for the limiting pulsed energy for each type of resistor in nanosecond and microsecond time ranges. The mechanisms of failure and destruction of resistors under the action of high voltage and high current pulses are discussed.

IEEE Conferences

Simulation, design and test of a MOV pulse shaping device for high power microwave generators

Authors: M. Giesselmann; T. Heeren; E. Kristiansen; J. Dickens; D. Castro; D. Garcia; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=823799

Abstract: This paper describes a metal oxide varistor (MOV) pulse shaping device, which is to be used for generating a flat-top voltage pulse for high power microwave devices. The MOV pulse-shaping device is attached to a coaxial pulse compression system. The pulse compression system consists of an inductive energy storage section, an exploding wire fuse and an output spark gap. The paper contains a detailed discussion of the pulse compression system followed by a description of the MOV pulse-shaping device. The MOV elements that are used for this pulse shaping application are the SIOV-E32VR602 type, made by Siemens.

IEEE Conferences

The design of a compact pulse transformer

Authors: J. Zhang; J. Dickens; M. Giesselmann; J. Kim; E. Kristiansen; J. Mankowski; D. Garcia; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=823610

Abstract: To improve the pulse shape and to obtain /spl mu/s order pulse duration on a diode load in an inductive energy storage system, an oil-submerged compact pulse transformer with diameter of 20 cm and length of 70 cm has been designed and tested. From theoretical calculations, the parameters with primary inductance L/sub p/=3.4 /spl mu/H, secondary inductance L/sub s/=90 /spl mu/H, and coupling coefficient K=0.772 are obtained. To prevent breakdown, a conical secondary design is adopted. Under the condition of 500 kV operation voltage, the maximum electric field in the transformer is 205 kV/cm (in oil). The axial voltage distribution on the secondary is linear. Experiments have been done to test the insulation, the mechanical force and the coupling coefficient. The test results are consistent with the design parameters.

IEEE Conferences

1998

A robust registration technique for multi-sensor images

Authors: G. Zamora; M. Dickens; S. Mitra

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=666865

Abstract: This paper describes an improved technique to register multi-sensor images by segmenting the images by adaptive clustering prior to performing preprocessing and cepstrum operation to determine the translational displacement. The difficulty in registering multi sensor images lies in the fact that the images of the same scene acquired by different sensors often appear different in detailed structures. Therefore the common features existing in such images need to be identified by suitable preprocessing operations for the success of the cepstral registration technique. Experimental results demonstrate the feasibility of successful cepstral registration of SAR and electro-optic images of the same scene despite apparent noticeable differences in some embedded structures thus providing a potential powerful tool for automated registration.

IEEE Conferences

Adaptive clustering for segmentation of multi-sensor images

Authors: S. Mitra; M. Dickens; S. Pemmaraju

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=686367

Abstract: Automatic detection or recognition of specific objects from a sequence of images acquired under varying conditions and from different modalities requires careful segmentation. We present here the use of an adaptive neuro-fuzzy clustering technique for image segmentation and boundary detection for better extraction of the dominant features in images of the same scene acquired by synthetic aperture radar (SAR) and electro-optic (EO) sensors. The advantage of such adaptive segmentation is clearer identification of objects that appear differently due to different sensor characteristics.

IEEE Conferences

Breakdown of dielectric/vacuum interfaces caused by high power microwaves

Authors: A. Neuber; J. Dickens; D. Hemmert; H. Krompholz; L. L. Hatfield; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=677696

Abstract: Summary form only given. Physical mechanisms leading to microwave breakdown on dielectric/vacuum interfaces are investigated for power levels on the order of 100 MW at 2.85 GHz. A 3 MW magnetron with 3.5 /spl mu/s pulse width, is coupled to an S-band traveling wave resonator which is kept at a pressure of 10/sup -8/ Torr. The investigation is focused on an interface geometry comprising a thin dielectric polymer slab in the waveguide, oriented vertical to the direction of wave propagation, and two field enhancement tips placed in the middle of each waveguide broad wall. This ensures an almost purely tangential field at the interface surface and a localized breakdown.

IEEE Conferences

High voltage subnanosecond breakdown

Authors: J. Mankowski; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=700858

Abstract: Present-day ultra-wideband radiation sources produce Megavolt pulses at hundreds of picosecond (ps) risetimes. Empirical data on the breakdown characteristics for dielectric media at these short time lengths and high voltages are either extremely limited or nonexistent. In support of the design of these ultra-wideband sources, we are investigating the breakdown characteristics, at these voltages and time lengths, of several liquids and high-pressure gases. These include air, N/sub 2/, H/sub 2/, SF/sub 6/, and transformer oil. Gap voltages attained were over 700 kV and gas pressures were over 150 atm (15 MPa). Breakdown times achieved were on the order of 600 ps. Electric field strengths observed for given breakdown times were higher than predicted by other investigators. An empirical fit is presented for the data obtained.

IEEE Journals

High voltage subnanosecond dielectric breakdown

Authors: J. Mankowski; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=677842

Abstract: Summary form only given, as follows. Present day ultra-wideband (UWB) radiation sources a produce Megavolt pulses at 100's of picosecond (ps) risetimes. Empirical data on the breakdown characteristics for dielectric media at these short time lengths and high voltages are either extremely limited or non-existent. In support of the design of these UWB sources, we are investigating the breakdown characteristics, at these voltages and time lengths, of several liquids and gases. These include air, N/sub 2/, H/sub 2/, He, SF/sub 6/, and transformer oil. The two voltage sources used in the experiments are capable of delivering 400 and 700 kV with a 400 ps risetime into an open load. These pulses are applied to the test gap area, capable of housing various gases and liquids at pressures from less than 1 to 150 atm. An empirical relationship of E-field versus breakdown time for the observed dielectrics is presented. Several other breakdown phenomena at these fast risetimes are observed. Dielectric breakdown strength dependence on polarity is investigated. Streak camera images of arc formation are captured, providing information on gap closure velocity. Also observed is the effect of ultraviolet radiation on the statistical lag time of breakdown for gas dielectrics at various pressures.

IEEE Conferences

Plasma destruction of battlefield chemical and biological warfare agents

Authors: E. O'Hair; J. Dickens; J. Fralick; L. Farrar

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=677653

Abstract: Summary form only given, as follows. Thermal plasmas are being evaluated for use in the destruction of deadly chemical and biological warfare agents. The technology approach consists of employing an electric arc to establish a plasma forming gas plume used to kill the harmful agents. The approach has been demonstrated on surrogate chemical and biological warfare agents. The harmful agents are rapidly destroyed, e.g., within a few seconds. Three different plasmas have been evaluated for their effectiveness to destroy harmful agents. The approaches used include nitrogen plasma, air plasma and a novel water plasma arcjet. The work incorporates an evaluation of the durability of the plasma arcjet technology for this application, e.g., cyclic life and steady-state durability. The follow-on phase of this project will result in a prototype system development suitable for field application. Anticipated benefits are the development of an effective system that will allow rapid and f-effective decontamination of surfaces that have been contaminated with chemical and biological warfare agents. No harmful byproducts will be produced. Additionally, the methods developed have application in the destruction of medical wastes, hazardous industrial wastes and in the destruction of hazardous materials associated with worldwide demilitarization activities.

IEEE Conferences

Removal of optical fiber interference in color micro-endoscopic images

Authors: M. M. Dickens; D. J. Bornhop; S. Mitra

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=701364

Abstract: Flexible micro-endoscopes produce images that are obscured by a 'honeycomb' pattern due to the negative space between the individual optical fibers contained in the imaging conduit. This pattern is found to exhibit a spatial frequency that is visibly distinct from that of the imaged object. By applying a frequency filter, it was possible to remove the honeycomb pattern without significant degradation to the visual quality of the image. This process greatly increases the perceived quality of the information being obtained by the endoscopes and aids in their effective use for medical diagnosis. The technique described employs Fourier spectral analysis to determine the 'noise' component in the original image. A discrete band-reject frequency filter was designed by visually examining the spectral information and creating the necessary filter to block out the undesired frequency bond. The honeycomb pattern was no longer distinguishable after applying this filter to a test gray-level image of an Air Force calibration target. Next, the filter was applied to the individual color planes of a sample color image. The color planes were recombined to produce a full-color image that was free from interference. A full description of the methods involved is presented.

IEEE Conferences

Window breakdown caused by high-power microwaves

Authors: A. Neuber; J. Dickens; D. Hemmert; H. Krompholz; L. L. Hatfield; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=700757

Abstract: Physical mechanisms leading to microwave breakdown on windows are investigated for power levels on the order of 100 MW at 2.85 GHz. The test stand uses a 3-MW magnetron coupled to an S-band traveling wave resonator. Various configurations of dielectric windows are investigated. In a standard pillbox geometry with a pressure of less than 10/sup -6/ Pa, surface discharges on an alumina window and multipactor-like discharges starting at the waveguide edges occur simultaneously. To clarify physical mechanisms, window breakdown with purely tangential electrical microwave fields is investigated for special geometries. Diagnostics include the measurement of incident/reflected power, measurement of local microwave fields, discharge luminosity, and X-ray emission. All quantities are recorded with 0.21-ns resolution. In addition, a framing camera with gating times of 5 ns is used. The breakdown processes for the case with a purely tangential electric field is similar to DC flashover across insulators, and similar methods to increase the flashover field are expected to be applicable.

IEEE Journals

1997

A subnanosecond high voltage pulser for the investigation of dielectric breakdown

Authors: J. Mankowski; J. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=679394

Abstract: A high voltage, sub-nanosecond pulser is designed and built for the purposes of investigating dielectric breakdown. The requirement for the pulser is a voltage pulse of several hundred kilovolts, pulsewidth less than a few nanoseconds, and a risetime <400 psec. This is achieved by using pulse sharpening techniques on the output of a 500 kV Marx bank. Originally designed to stimulate a lightning strike, the voltage waveform from the Marx generator has a slow decay time of tens of /spl mu/sec. In order to obtain a more desirable pulse, the Marx bank is modified. By removing a lumped-element resistor a higher peak output voltage with a faster risetime can be obtained. Circuit simulations have shown the capability of achieving an 800 kV output in less than 40 nsec to a charging (pulse forming) line. The 50 /spl Omega/ impedance, oil-filled, pulse forming line consists of a peaking gap and pulse slicing gap. The peaking gap decreases the risetime of the applied pulse down to about 300 psec. The pulse slicing gap is included to short the voltage applied to the delay line and test chamber.

IEEE Conferences

Evaluation of a Russian SOS diode for use in a compact modulator system

Authors: J. Dickens; M. Kristiansen; M. Giesselmann; J. G. Kim

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=679365

Abstract: A Russian power modulator, which is based on a diode that has been touted as a high-power solid-state pulsed power opening switch (SOS) was characterized and tested. The diode has characteristics similar to those of a step-recovery diode, except that the reverse current density is 10-100 times larger than in US manufactured diodes. The modulator has a DC input voltage of 600 V and produces a pulse of 150 kV amplitude and 25 ns half width into a 350 /spl Omega/ load. The maximum pulse repetition rate is 100 Hz. The limit is given by thermal limitations and can be increased through the use of more effective cooling methods.

IEEE Conferences

Streamer Discharges By Pulsed Power On A Spiral Transmission Line

Authors: Akiyama, H; Nishihashi, Y; Tsukamoto, S; Sueda, T; Katsuki, S; Hagler, M; Dickens, JC; Inoue, N

PDF: https://ieeexplore.ieee.org/document/679286

Abstract: Streamer corona discharges produced by pulsed power make enough high energy electrons to dissociate gases directly. Consequently, pulsed streamer discharges have been proposed for the removal of NOx and SO2 from flue gases, the production of ozone and the treatment of poisonous gases. It is proposed here to produce the pulsed streamer discharges on a spiral transmission line. The characteristics of the discharges are studied, comparing with results using a PSpice code. Then, the effectiveness and advantages of the spiral transmission line are discussed in view of real applications.

Conference Paper/Presentation

Window And Cavity Breakdown Caused By High Power Microwaves

Authors: Neuber, A; Dickens, J; Hemmert, D; Krompholz, H; Hatfield, LL; Kristiansen, M

PDF: https://ieeexplore.ieee.org/document/604787

Abstract: Physical mechanisms leading to microwave breakdown on windows and in cavities are investigated for power levels on the order of 100 MW at 2.85 GHz. The test stand uses a 3 MW magnetron coupled to an S-band traveling wave resonator. Various configurations of dielectric windows are investigated. In a standard pillbox geometry with a pressure of less than 10(-8) torr, surface discharges on an alumina window and multipactor-like discharges starting at the waveguide edges occur simultaneously. To clarify physical mechanisms, window breakdown with purely tangential electrical microwave fields is investigated for special geometries. Other configurations, such as air filled two window setups, relevant for vacuum-air interfaces, can be investigated as well. Diagnostics include the measurement of incident/reflected power, measurement of local microwave fields, discharge luminosity, and x-ray emission. All quantities are recorded with 0.2 to 1 ns resolution. In addition, a framing camera with gating times of 5 ns is used. Based on the experimental results, methods to increase the power density which can be transmitted through windows, such as surface coatings and window profiles, will be investigated as well.

Conference Paper/Presentation

1996

Breakdown at window interfaces caused by high power microwave fields

Authors: J. C. Dickens; J. Elliott; L. L. Hatfield; M. Kristiansen; H. Krompholz

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=551438

Abstract: Summary form only given. Investigations of breakdown phenomena at window interfaces from high vacuum (<10/sup -7/ torr) to atmospheric pressure are investigated for microwave power levels of up to 100 MW. The test stand utilizes a 3 MW magnetron operating at 2.8 GHz, coupled to an S-band traveling wave resonant ring. Various configurations of dielectric windows (i.e. vacuum-air, or vacuum-vacuum), in various geometries (standard pillbox geometry, or windows filling the S-band waveguide cross section) are investigated. Diagnostics include the measurement of transmitted/reflected microwave power, luminosity from the discharge plasma, X-ray emission from initially free electrons, and electric field probes. All these quantities are measured with high amplitude and high temporal (0.2 to 1 ns) resolution. Goals are to determine the physical mechanisms-such as the dominant electron multiplication process-leading to flashover. The knowledge gained from these experiments is used to investigate and design methods to increase the power density which can be transmitted through windows. In addition, parametric studies are conducted, in which window material, profile, and surface coatings are varied. The basic system and the diagnostics methods are expanded for the investigation of microwave cavity breakdown as well.

IEEE Conferences

Compact modulator using inductive energy storage and a solid state opening switch

Authors: J. C. Dickens; J. Bridges; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=564449

Abstract: A compact modulator system using inductive energy storage and a diode as an opening switch was investigated. The system was designed around a Russian diode that has characteristics similar to those of a step-recovery diode except that the reverse current density is 10-100 times larger than in US manufactured diodes. The main goal of this investigation was to characterize the Russian diode and develop an understanding of its operation for possible improvement and integration into nanosecond pulse generators. The basic modulator circuit designed uses IGBTs in the forward pumping circuit and is capable of delivering 5 kV at 400 A into the diode. Using this forward pumping circuit, diode voltage and current measurements were made at several input power levels. In addition, data obtained using this test stand was used to produce a computer simulation model of the diode for a more thorough circuit analysis.

IEEE Conferences

1993

Electrode Performance Of A 3 Electrode Triggered High Energy Spark Gap Switch

Authors: DICKENS, JC; ENGEL, TG; KRISTIANSEN, M

PDF: https://ieeexplore.ieee.org/document/513376

Abstract: Electrode erosion rates and voltage holdoff !ability are presented for various electrode materials sed in a triggered spark gap switch. The switch tilized an electrical trigger with the triggered electrode ositioned perpendicular to the main gap. Results show significant reduction in electrode erosion rates over Lose for non-triggered gaps. The lowered erosion rates re attributed in part to the lower voltage and current roduct during switch turn-on. The tests are conducted xoss a broad range of peak currents (i.e. 10 kA - 400 A) and materials, includmg copper-tungsten, coppermgsten+LaBg, and tungste

Conference Paper/Presentation

Insulator and electrode mass erosion and surface voltage holdoff recovery for transient, high current surface discharges

Authors: T. G. Engel; J. C. Dickens; M. Kristiansen

PDF: https://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=195742

Abstract: Several polymeric insulator materials commonly used as sidewall insulators in electromagnetic accelerators were subjected to repetitive (from approximately 0.1 to 1 discharge per second), high current (from approximately 100 to 300 kA peak or approximately 100 to 300 kA/cm), transient ( approximately 20 mu s pulse width) surface discharges. The insulator materials tested include the thermosetting polymers G-9, G-10, and G-11 (i.e., fiberglass reinforced melamine and epoxy) and the thermoplastic polymers Lexan (i.e., polycarbonate) and Delrin (i.e., polyacetyl). Empirical scaling relationships are given that relate the amount of insulator and electrode (i.e., molybdenum) mass erosion to the total amount of arc energy transferred. Scaling relationships are also given for the lifetime of the given polymer as a function of the initial discharge current. The lifetime of an insulator material is defined as the number of discharges required to reduce the initial surface holdoff voltage to its half-power level for three consecutive discharges and is a useful parameter when specifying insulator materials to be used in high-power switching devices.<>